Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = QUIPU-HSQC

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
11 pages, 2358 KiB  
Article
Robust Metabolite Quantification from J-Compensated 2D 1H-13C-HSQC Experiments
by Alexander Weitzel, Claudia Samol, Peter J. Oefner and Wolfram Gronwald
Metabolites 2020, 10(11), 449; https://doi.org/10.3390/metabo10110449 - 7 Nov 2020
Cited by 9 | Viewed by 2788
Abstract
The spectral resolution of 2D 1H-13C heteronuclear single quantum coherence (1H-13C-HSQC) nuclear magnetic resonance (NMR) spectra facilitates both metabolite identification and quantification in nuclear magnetic resonance-based metabolomics. However, quantification is complicated by variations in magnetization transfer, [...] Read more.
The spectral resolution of 2D 1H-13C heteronuclear single quantum coherence (1H-13C-HSQC) nuclear magnetic resonance (NMR) spectra facilitates both metabolite identification and quantification in nuclear magnetic resonance-based metabolomics. However, quantification is complicated by variations in magnetization transfer, which among others originate mainly from scalar coupling differences. Methods that compensate for variation in scalar coupling include the generation of calibration factors for individual signals or the use of additional pulse sequence schemes such as quantitative HSQC (Q-HSQC) that suppress the JCH-dependence by modulating the polarization transfer delays of HSQC or, additionally, employ a pure-shift homodecoupling approach in the 1H dimension, such as Quantitative, Perfected and Pure Shifted HSQC (QUIPU-HSQC). To test the quantitative accuracy of these three methods, employing a 600 MHz NMR spectrometer equipped with a helium cooled cryoprobe, a Latin-square design that covered the physiological concentration ranges of 10 metabolites was used. The results show the suitability of all three methods for the quantification of highly abundant metabolites. However, the substantially increased residual water signal observed in QUIPU-HSQC spectra impeded the quantification of low abundant metabolites located near the residual water signal, thus limiting its utility in high-throughput metabolite fingerprinting studies. Full article
(This article belongs to the Special Issue Advances in Cellular Metabolomics)
Show Figures

Graphical abstract

Back to TopTop