error_outline You can access the new MDPI.com website here. Explore and share your feedback with us.
 
 
Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = Myakka fine sandy soil

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
21 pages, 6222 KB  
Article
Timescale of Groundwater Recharge in High Percolation Coastal Plain Soils
by Qing Du and Mark Ross
Water 2024, 16(10), 1320; https://doi.org/10.3390/w16101320 - 7 May 2024
Cited by 1 | Viewed by 2317
Abstract
Understanding and modeling the timing and magnitude of groundwater recharge from rainfall infiltration through vadose-zone percolation is important for many reasons but especially because the flux is being acted on by root-zone evapotranspiration (ET), and very little rainfall infiltration ever becomes water-table recharge. [...] Read more.
Understanding and modeling the timing and magnitude of groundwater recharge from rainfall infiltration through vadose-zone percolation is important for many reasons but especially because the flux is being acted on by root-zone evapotranspiration (ET), and very little rainfall infiltration ever becomes water-table recharge. This study elaborates on the considerable time of the wetting front’s arrival and ultimate bulk recharge of rainfall infiltration in the shallow water table with fine-sandy soil typical of coastal plain environments such as Florida. Calibrated Hydrus-1D modeling of Florida (Myakka) soil was evaluated at varying depths of the water table and hydraulic conductivities to bracket the timing of arrival of the wetting front and bulk fluxes. Useful normalized timing parameters are defined. In addition, this research further quantifies the concept of “wet equilibrium”, and the considerable vadose-zone storage potential over and above the hydrostatic pressure equilibrium that must be overcome to achieve any significant water-table recharge in typical seasonal hydrologic timescales. The results indicate recharge timescales for water-table depths of 1 m are approximately 1 day but are considerably longer for 2 m (2 weeks), 3 m (1 month), and 4 m (50 days) conditions. Given that daily vadose-zone potential ET demand can exceed 0.5 cm/day in this environment, estimating recharge from rainfall infiltration is likely unreliable unless this timescale and the plant-root-zone uptake processes are properly modeled in surface-groundwater models. Full article
(This article belongs to the Topic Hydrology and Water Resources Management)
Show Figures

Figure 1

Back to TopTop