Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (3)

Search Parameters:
Keywords = MiniMedTM 780G

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
10 pages, 252 KiB  
Article
Real-World Use of Hybrid Closed-Loop Systems during Diabetes Camp: A Preliminary Study for Secure Configuration Strategies in Children and Adolescents
by María José Olid-Cárdenas, Alfonso Lendínez-Jurado, Gabriela Monroy-Rodríguez, Ana Gómez-Perea, Ana Cano-Ortiz, Ana B. Ariza-Jiménez, Ana García-Ruiz, Patricia Jiménez-Cuenca, María José Picón-César and Isabel Leiva-Gea
Nutrients 2024, 16(14), 2210; https://doi.org/10.3390/nu16142210 - 10 Jul 2024
Cited by 1 | Viewed by 1680
Abstract
The introduction of closed-loop systems in the pediatric population has been a revolution in the management and evolution of diabetes. However, there are not many published studies in situations in which the feeding, schedules, and activities of the children deviate from the routine [...] Read more.
The introduction of closed-loop systems in the pediatric population has been a revolution in the management and evolution of diabetes. However, there are not many published studies in situations in which the feeding, schedules, and activities of the children deviate from the routine for which the systems were programmed, as in the case of a summer camp for children and adolescents with diabetes, where the specific programming of this device is not well known. It was a single-center prospective preliminary study. A total of twenty-seven patients (mean age 11.9 ± 1.9 years, 40% male, duration of diabetes 6.44 ± 2.83 years) were included (twenty with Medtronic MiniMed 780G system and seven with Tandem Control-IQ). Glucometric variables and pump functionality were monitored during the 7-day camp and in the following 3 weeks. There was no decrease from the objective TIR 70% at any moment. The worst results in Time Below Range were at 72 h from starting the camp, and the worst results in Time Above Range were in the first 24 h, with a progressive improvement after that. No episodes of level 3 hypoglycemia or ketoacidosis occurred. The use of specific programming in two integrated systems, with complex blood glucose regulation algorithms and not-prepared-for situations with increased levels of physical activity or abrupt changes in feeding routines, did not result in an increased risk of level 3 hypoglycemia and ketoacidosis for our pediatric type 1 diabetes (T1D) patients, regardless of the closed-loop device. Full article
(This article belongs to the Special Issue Dietary and Behavioral Interventions for Diabetes)
10 pages, 452 KiB  
Article
Use of Advanced Hybrid Closed-Loop System during Pregnancy: Strengths and Limitations of Achieving a Tight Glycemic Control
by Parthena Giannoulaki, Evangelia Kotzakioulafi, Alexandros Nakas, Zisis Kontoninas, Polykarpos Evripidou and Triantafyllos Didangelos
J. Clin. Med. 2024, 13(5), 1441; https://doi.org/10.3390/jcm13051441 - 1 Mar 2024
Cited by 4 | Viewed by 2232
Abstract
Background: Pregnant women with type 1 diabetes mellitus (T1DM) face an elevated risk of complications for both themselves and their newborns. Experts recommend strict glycemic control. The advanced hybrid closed-loop (AHCL) system, though not officially approved for pregnant T1DM patients, is promising [...] Read more.
Background: Pregnant women with type 1 diabetes mellitus (T1DM) face an elevated risk of complications for both themselves and their newborns. Experts recommend strict glycemic control. The advanced hybrid closed-loop (AHCL) system, though not officially approved for pregnant T1DM patients, is promising for optimal glycemic control. Methods: We collected CGM metrics, HbA1c levels, insulin pump settings, and doses from a 33-year-old pregnant woman with 23-year history of T1DM from the 6th week of gestation to birth. She was initially on continuous insulin pump therapy with CGM and switched to the AHCL system (MiniMedTM 780G, Medtronic, Northridge, CA, USA) between weeks 13 and 14. Results: The AHCL system improved glycemic control from weeks 14 to 26, achieving international guidelines with TIR = 72%, TAR = 24%, TBR = 4%. At week 30, TIR was 66%, TAR 31%. By altering diet and adding ‘fake carbohydrates’, she maintained TIR ≥ 70%, TBR ≤ 4%, TAR ≤ 26% from week 34 to birth. A healthy 4 kg, 53 cm baby boy was born at week 38. Conclusions: The use of the AHCL system holds significant promise for improving glycemic control in pregnancy. Optimal glycemic control with MiniMedTM 780G in pregnancy requires accurate carbohydrate counting, specific timing of insulin doses in relation to meal consumption and dietary choices that reduce the glycemic load of meals continue to be crucial factors in achieving optimal glycemic control during pregnancy using the MiniMedTM 780G system. Further research and clinical studies are needed to explore the full potential of these advanced systems in managing T1DM during pregnancy and optimizing maternal and neonatal outcomes. Full article
Show Figures

Figure 1

10 pages, 487 KiB  
Article
Pediatric Type 1 Diabetes: Is Age at Onset a Determining Factor in Advanced Hybrid Closed-Loop Insulin Therapy?
by Alfonso Lendínez-Jurado, Juan Pedro López-Siguero, Ana Gómez-Perea, Ana B. Ariza-Jiménez, Icía Becerra-Paz, Leopoldo Tapia-Ceballos, Carmen Cruces-Ponce, José Manuel Jiménez-Hinojosa, Sonsoles Morcillo and Isabel Leiva-Gea
J. Clin. Med. 2023, 12(21), 6951; https://doi.org/10.3390/jcm12216951 - 6 Nov 2023
Cited by 1 | Viewed by 1652
Abstract
Background: The integration of continuous glucose monitoring systems with insulin infusion pumps has shown improved glycemic control, with improvements in hyperglycemia, hypoglycemia, Hb1Ac, and greater autonomy in daily life. These have been most studied in adults and there are currently not many articles [...] Read more.
Background: The integration of continuous glucose monitoring systems with insulin infusion pumps has shown improved glycemic control, with improvements in hyperglycemia, hypoglycemia, Hb1Ac, and greater autonomy in daily life. These have been most studied in adults and there are currently not many articles published in the pediatric population that establish their correlation with age of debut. Methods: Prospective, single-study. A total of 28 patients (mean age 12 ± 2.43 years, 57% male, duration of diabetes 7.84 ± 2.46 years) were included and divided into two groups according to age at T1D onset (≤4 years and >4 years). Follow-up for 3 months, with glucometric variables extracted at different cut-off points after the start of the closed-loop (baseline, 1 month, 3 months). Results: Significant improvement was evidenced at 1 month and 3 months after closed-loop system implantation, with better glycemic control in the older age group at baseline at TIR (74.06% ± 6.37% vs. 80.33% ± 7.49% at 1 month, p < 0.003; 71.87% ± 6.58% vs. 78.75% ± 5.94% at 3 months, p < 0.009), TAR1 (18.25% ± 4.54% vs. 14.33% ± 5.74% at 1 month, p < 0.006; 19.87% ± 5.15% vs. 14.67% ± 4. 36% at 3 months, p < 0.009) and TAR2 (4.75% ± 2.67% vs. 2.75% ± 1.96% at 1 month, p = 0.0307; 5.40% ± 2.85% vs. 3% ± 2.45% at 3 months, p < 0.027). Conclusions: the use of automated systems such as the MiniMedTM780G system brings glucometric results closer to those recommended by consensus, especially in age at T1D onset >4 years. However, the management in pediatrics continues to be a challenge even after the implementation of these systems, especially in terms of hyperglycemia and glycemic variability. Full article
(This article belongs to the Special Issue Endocrine Disorders in Children)
Show Figures

Graphical abstract

Back to TopTop