Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = MWCNT-CDC fibers

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 3214 KiB  
Article
Hardware and Software Development for Isotonic Strain and Isometric Stress Measurements of Linear Ionic Actuators
by Madis Harjo, Tarmo Tamm, Gholamreza Anbarjafari and Rudolf Kiefer
Polymers 2019, 11(6), 1054; https://doi.org/10.3390/polym11061054 - 17 Jun 2019
Cited by 28 | Viewed by 3811
Abstract
An inseparable part of ionic actuator characterization is a set of adequate measurement devices. Due to significant limitations of available commercial systems, in-house setups are often employed. The main objective of this work was to develop a software solution for running isotonic and [...] Read more.
An inseparable part of ionic actuator characterization is a set of adequate measurement devices. Due to significant limitations of available commercial systems, in-house setups are often employed. The main objective of this work was to develop a software solution for running isotonic and isometric experiments on a hardware setup consisting of a potentiostat, a linear displacement actuator, a force sensor, and a voltmeter for measuring the force signal. A set of functions, hardware drivers, and measurement automation algorithms were developed in the National Instruments LabVIEW 2015 system. The result is a software called isotonic (displacement) and isometric (force) electro-chemo-measurement software (IIECMS), that enables the user to control isotonic and isometric experiments over a single compact graphical user interface. The linear ionic actuators chosen as sample systems included different materials with different force and displacement characteristics, namely free-standing polypyrrole films doped with dodecylbenzene sulfonate (PPy/DBS) and multiwall carbon nanotube/carbide-derived carbon (MWCNT-CDC) fibers. The developed software was thoroughly tested with numerous test samples of linear ionic actuators, meaning over 200 h of experimenting time where over 90% of the time the software handled the experiment process autonomously. The uncertainty of isotonic measurements was estimated to be 0.6 µm (0.06%). With the integrated correction algorithms, samples with as low as 0 dB signal-to-noise ratio (SNR) can be adequately described. Full article
Show Figures

Figure 1

Back to TopTop