Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = H-rGO-Pd NPs nanozyme

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 2365 KiB  
Article
H-rGO-Pd NPs Nanozyme Enhanced Silver Deposition Strategy for Electrochemical Detection of Glypican-3
by Guiyin Li, Bo Wang, Ling Li, Xinhao Li, Ruijie Yan, Jintao Liang, Xinchun Zhou, Liuxun Li and Zhide Zhou
Molecules 2023, 28(5), 2271; https://doi.org/10.3390/molecules28052271 - 28 Feb 2023
Cited by 19 | Viewed by 2711
Abstract
Glypican-3 (GPC3), as an emerging biomarker, has been shown to be beneficial for the early diagnosis and treatment of hepatocellular carcinoma (HCC). In this study, an ultrasensitive electrochemical biosensor for GPC3 detection has been constructed based on the hemin-reduced graphene oxide-palladium nanoparticles (H-rGO-Pd [...] Read more.
Glypican-3 (GPC3), as an emerging biomarker, has been shown to be beneficial for the early diagnosis and treatment of hepatocellular carcinoma (HCC). In this study, an ultrasensitive electrochemical biosensor for GPC3 detection has been constructed based on the hemin-reduced graphene oxide-palladium nanoparticles (H-rGO-Pd NPs) nanozyme-enhanced silver deposition signal amplification strategy. When GPC3 specifically interacted with GPC3 antibody (GPC3Ab) and GPC3 aptamer (GPC3Apt), an “H-rGO-Pd NPs-GPC3Apt/GPC3/GPC3Ab” sandwich complex was formed with peroxidase-like properties which enhanced H2O2 to reduce the silver (Ag) ions in solution to metallic Ag, resulting in the deposition of silver nanoparticles (Ag NPs) on the surface of the biosensor. The amount of deposited Ag, which was derived from the amount of GPC3, was quantified by the differential pulse voltammetry (DPV) method. Under ideal circumstances, the response value was linearly correlated with GPC3 concentration at 10.0–100.0 μg/mL with R2 of 0.9715. When the GPC3 concentration was in the range from 0.01 to 10.0 μg/mL, the response value was logarithmically linear with the GPC3 concentration with R2 of 0.9941. The limit of detection was 3.30 ng/mL at a signal-to-noise ratio of three and the sensitivity was 1.535 μAμM−1cm−2. Furthermore, the electrochemical biosensor detected the GPC3 level in actual serum samples with good recoveries (103.78–106.52%) and satisfactory relative standard deviations (RSDs) (1.89–8.81%), which confirmed the applicability of the sensor in practical applications. This study provides a new analytical method for measuring the level of GPC3 in the early diagnosis of HCC. Full article
Show Figures

Figure 1

Back to TopTop