14 pages, 443 KiB  
Article
Development and Validation of a Novel Stability-Indicating RP-HPLC Method for the Simultaneous Determination of Halometasone, Fusidic Acid, Methylparaben, and Propylparaben in Topical Pharmaceutical Formulation
by Nishant GOSWAMI, V. Rama Mohan GUPTA and Hitesh A. JOGIA
Sci. Pharm. 2013, 81(2), 505-518; https://doi.org/10.3797/scipharm.1301-21 - 25 Feb 2013
Cited by 22 | Viewed by 3013
Abstract
A stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for the simultaneous determination of halometasone, fusidic acid, methylparaben, and propylparaben in topical pharmaceutical formulation. The desired chromatographic separation was achieved on an Agilent Zorbax CN (Cyano), 5 μm (250 x 4.6 mm) [...] Read more.
A stability-indicating reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for the simultaneous determination of halometasone, fusidic acid, methylparaben, and propylparaben in topical pharmaceutical formulation. The desired chromatographic separation was achieved on an Agilent Zorbax CN (Cyano), 5 μm (250 x 4.6 mm) column using gradient elution at 240 nm detector wavelength. The optimized mobile phase consisted of a mixture of 0.01 M phosphate buffer and 0.1% orthophosphoric acid, pH-adjusted to 2.5 with an ammonia solution as solvent-A and acetonitrile as solvent-B. The developed method separated halometasone, fusidic acid, methylparaben, and propylparaben in the presence of known impurities/ degradation products. The stability-indicating capability was established by forced degradation experiments and separation of known and unknown degradation products. The developed RP-HPLC method was validated according to the International Conference on Harmonization (ICH) guidelines. This validated method was applied for the simultaneous estimation of HM, FA, MP, and PP in commercially available cream samples. Further, the method can be extended for the estimation of HM, FA, MP, and PP in various commercially available dosage forms. Full article