Electrochemical Immunosensor for Simultaneous Determination of Emerging Autoimmune Disease Biomarkers in Human Serum †

,
,
,
,
and
Department of Analytical Chemistry, Faculty of Chemistry, University Complutense of Madrid, Avda. Complutense s/n, 28040 Madrid, Spain
*
Author to whom correspondence should be addressed.
Presented at the 1st International Electronic Conference on Chemical Sensors and Analytical Chemistry, 1–15 July 2021; Available online: https://csac2021.sciforum.net/.
This article belongs to the Proceedings The 1st International Electronic Conference on Chemical Sensors and Analytical Chemistry

Abstract

Rheumatoid arthritis is an autoimmune disorder characterized by persistent erosive synovitis, systemic inflammation and the presence of autoantibodies, which play an important role in inducing inflammation and joint damage, releasing pro-inflammatory cytokines from monocytes and macrophages [1,2]. Likewise, neutrophil activating protein-2 (CXCL7) is a platelet-derived growth factor belonging to the CXC chemokine subfamily, which is expressed in serum, synovial fluid and synovial tissue of patients developing rheumatoid arthritis during the first twelve weeks, being useful to reflect local pathological changes [3]. Besides, matrix metalloproteinase-3 (MMP-3), which is induced by inflammatory cytokines such as interleukin-1 (IL-1) and tumor necrosis factor alpha (TNF-α) in rheumatoid synovium, degrades several extracellular matrix components of cartilage and plays central roles in rheumatoid joint destruction [4]. Therefore, monitoring serum CXCL7 and MMP-3 levels is useful for predicting the disease activity in rheumatoid arthritis. In this work, the construction and analytical performance of a dual electrochemical platform for the simultaneous determination of CXCL7 and MMP-3 is described. After the optimization of experimental variables involved in the preparation and implementation of the biosensor, the analytical usefulness of the developed configuration was demonstrated by its application to the determination of these biomarkers in serum samples from healthy individuals and patients with rheumatoid arthritis. To carry out the simultaneous determination of CXCL7 and MMP3 in human serum, just a fifty-fold sample dilution in PBS of pH 7.4 was required. In addition, the results obtained using the dual immunosensor were compared with those provided by the respective ELISA immunoassays, yielding no significant differences between the two methods. It is important to highlight that reagents consumption, four times smaller using the dual immunosensor than that required in the ELISA protocol, and an assay time of 2 h 50 min versus almost 5 h, counted in both cases after incubation of the capture antibody, are advantageous features of the dual immunosensor [5].

Supplementary Materials

The following are available online at https://www.mdpi.com/article/10.3390/CSAC2021-10437/s1.

Author Contributions

Conceptualization, P.Y.-S.; methodology, E.S.-T., S.G., A.G.-C. and L.A.; software, E.S.-T. and S.G.; validation, E.S.-T., S.G., A.G.-C. and L.A.; formal analysis, E.S.-T., S.G., A.G.-C. and L.A.; investigation, E.S.-T., S.G., A.G.-C. and L.A.; resources, A.G.-C., L.A. and P.Y.-S.; data curation, E.S.-T. and S.G.; validation, E.S.-T., S.G., A.G.-C. L.A., P.Y.-S.; writing—original draft preparation, E.S.-T., S.G., A.G.-C., L.A. and P.Y.-S.; writing—review and editing, P.Y.-S. and J.M.P.; visualization, E.S.-T., S.G., A.G.-C. and L.A.; resources, A.G.-C., L.A. and P.Y.-S.; supervision, A.G.-C., L.A., P.Y.-S.; funding acquisition, A.G.-C., P.Y.-S. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by Spanish Ministerio de Ciencia, Innovación y Universidades, grant number RTI2018-096135-B-I00 and TRANSNANOAVANSENS-CM Program from the Comunidad de Madrid, grant number S2018/NMT-4349.

Institutional Review Board Statement

Not applicable.

Data Availability Statement

Guerrero, S.; Sánchez-Tirado, E.; Agúí, L.; González-Cortés, A.; Yáñez-Sedeño, P.; Pingarrón, J.M. Simultaneous determina-tion of CXCL7 chemokine and MMP3 metalloproteinase as biomarkers for rheumatoid arthritis. Talanta 2021, 234, 122705.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Bos, W.H.; Wolbink, G.J.; Boers, M.; Tijhuis, G.J.; de Vries, N.; van der Horst-Bruinsma, I.E.; Tak, P.P.; van de Stadt, R.J.; van der Laken, C.J.; Dijkmans, B.A.C.; et al. Arthritis development in patients with arthralgia is strongly associated with anti-citrullinated protein antibody status: A prospective cohort study. Ann. Rheum. Dis. 2010, 69, 490–494. [Google Scholar] [CrossRef]
  2. Scott, D.L.; Wolfe, F.; Huizinga, T.W.J. Rheumatoid arthritis. Lancet 2010, 376, 1094–1108. [Google Scholar] [CrossRef]
  3. Guerrero, S.; Cadano, D.; Agüí, L.; Barderas, R.; Campuzano, S.; Yáñez-Sedeño, P.; Pingarrón, J.M. Click chemistry-assisted antibodies immobilization for immunosensing of CXCL7 chemokine in serum. J. Electroanal. Chem. 2019, 837, 246–253. [Google Scholar] [CrossRef]
  4. Sugiyama, E. Role of matrix metalloproteinase-3 in joint destruction in rheumatoid arthritis. Clin. Calcium 2007, 17, 528–534. [Google Scholar] [PubMed]
  5. Guerrero, S.; Sánchez-Tirado, E.; Agúí, L.; González-Cortés, A.; Yáñez-Sedeño, P.; Pingarrón, J.M. Simultaneous determination of CXCL7 chemokine and MMP3 metalloproteinase as biomarkers for rheumatoid arthritis. Talanta 2021, 234, 122705. [Google Scholar] [CrossRef] [PubMed]
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.