Next Article in Journal
Preliminary Study on Electrochemical Ion Imprinted Polymeric Film in Sensor Development for Cd(II) Ions Determination in Water
Previous Article in Journal
Highly Multiplexed Label-Free Imaging Sensor for Accurate Quantification of Small-Molecule Binding Kinetics
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Proceeding Paper

Microfluidic Impedance Biosensor Chip with DNA-Based Self-Assembled Monolayers for Label-Free Detection of Cardiac Biomarker Troponin I †

1
Institute of Microstructure Technology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
2
Institute for Micro Process Engineering, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, 76344 Eggenstein-Leopoldshafen, Germany
*
Author to whom correspondence should be addressed.
Presented at the 1st International Electronic Conference on Biosensors, 2–17 November 2020; Available online: https://iecb2020.sciforum.net/.
Proceedings 2020, 60(1), 38; https://doi.org/10.3390/IECB2020-07033
Published: 2 November 2020
(This article belongs to the Proceedings of The 1st International Electronic Conference on Biosensors)

Abstract

A microfluidic chip for electrochemical impedance spectroscopy (EIS) is presented as biosensor for the detection of cardiac troponin I (cTnI). Troponin I is one of the most specific diagnostic serum biomarkers for myocardial infarction. As impedimetric biosensors allow direct and label-free analyte detection, they are particularly suitable for fast biomarker detection. This is essential in the diagnosis of cardiac infarctions to enable an early treatment promoting a positive outcome. The microfluidic impedance biosensor chip presented here consists of a microscope glass slide serving as base plate, sputtered electrodes, and a polydimethylsiloxane (PDMS) microchannel. Electrode functionalization protocols were developed considering a low initial impedance in addition to analyte-specific binding by corresponding antibodies and reduction of non-specific protein adsorption to prevent false-positive signals. Reagents tested for self-assembled monolayers (SAMs) on gold electrodes included thiolated hydrocarbons and thiolated oligonucleotides, where SAMs based on the latter showed a better performance. The corresponding antibody (anti-cTnI) was covalently coupled on the SAM using carbodiimide chemistry. The PDMS microchannel was bonded on the glass slide with the functionalized electrodes, and the completed microfluidic impedance biosensor chip was connected to the readout system. Sampling and measurement took only a few minutes. Application of a human serum albumin (HSA) sample, 1000 ng/mL, led to negligible signal changes, while application of a troponin I sample, 1 ng/mL, led to a significant signal shift in the Nyquist plot. The results are promising regarding specific detection of clinically relevant concentrations of cardiac markers with the newly developed impedance biosensor chip.
Keywords: biosensor; cardiac troponin I; single-strand DNA; electrochemical impedance spectroscopy; label-free; microfluidic chip; self-assembled monolayers biosensor; cardiac troponin I; single-strand DNA; electrochemical impedance spectroscopy; label-free; microfluidic chip; self-assembled monolayers

Share and Cite

MDPI and ACS Style

Alsabbagh, K.; Hornung, T.; Voigt, A.; Sadir, S.; Rajabi, T.; Länge, K. Microfluidic Impedance Biosensor Chip with DNA-Based Self-Assembled Monolayers for Label-Free Detection of Cardiac Biomarker Troponin I. Proceedings 2020, 60, 38. https://doi.org/10.3390/IECB2020-07033

AMA Style

Alsabbagh K, Hornung T, Voigt A, Sadir S, Rajabi T, Länge K. Microfluidic Impedance Biosensor Chip with DNA-Based Self-Assembled Monolayers for Label-Free Detection of Cardiac Biomarker Troponin I. Proceedings. 2020; 60(1):38. https://doi.org/10.3390/IECB2020-07033

Chicago/Turabian Style

Alsabbagh, Khaled, Tim Hornung, Achim Voigt, Sahba Sadir, Taleieh Rajabi, and Kerstin Länge. 2020. "Microfluidic Impedance Biosensor Chip with DNA-Based Self-Assembled Monolayers for Label-Free Detection of Cardiac Biomarker Troponin I" Proceedings 60, no. 1: 38. https://doi.org/10.3390/IECB2020-07033

APA Style

Alsabbagh, K., Hornung, T., Voigt, A., Sadir, S., Rajabi, T., & Länge, K. (2020). Microfluidic Impedance Biosensor Chip with DNA-Based Self-Assembled Monolayers for Label-Free Detection of Cardiac Biomarker Troponin I. Proceedings, 60(1), 38. https://doi.org/10.3390/IECB2020-07033

Article Metrics

Back to TopTop