Next Article in Journal
Diagnostic Accuracy of the Cobas® MTB and Cobas MTB/RIF-INH Assays on Sputum and the Cobas MTB Assay on Tongue Swabs for Mycobacterium tuberculosis Complex Detection in Symptomatic Adults in South Africa
Previous Article in Journal
Spatial Proximity of Cancer-Associated Fibroblasts to Tumor and Osteoclasts Suggests a Coordinating Role in OSCC-Induced Bone Invasion: A Preliminary Study
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
This is an early access version, the complete PDF, HTML, and XML versions will be available soon.
Article

Deep-Learning Model for Iris and Eyebrow Segmentation and Automation of Eye Landmark Measurements in Acquired Ptosis

1
School of Medicine, Konkuk University, Chungju 27478, Republic of Korea
2
Department of Ophthalmology, Konkuk University Medical Center, Seoul 05030, Republic of Korea
3
Research Institute of Medical Science, Konkuk University, Seoul 05029, Republic of Korea
*
Author to whom correspondence should be addressed.
Biomedicines 2025, 13(10), 2557; https://doi.org/10.3390/biomedicines13102557
Submission received: 31 August 2025 / Revised: 8 October 2025 / Accepted: 17 October 2025 / Published: 20 October 2025
(This article belongs to the Section Molecular and Translational Medicine)

Abstract

Background: Acquired ptosis is a common eyelid disorder in elderly patients, causing visual disturbance and cosmetic concerns. Accurate evaluation of periocular anatomy, including eyebrow and iris position, is essential for surgical planning, but current manual assessments are time-consuming and subjective. Objectives: This study aimed to develop deep-learning models for iris and eyebrow segmentation to automate eye landmark measurements and enable objective, standardized analysis in patients with acquired ptosis. Methods: We retrospectively collected 612 facial images from 209 ptosis patients. Images were labeled for iris and eyebrow segmentation and split into training, validation, and test sets (8:1:1). A deep-learning model was developed to automatically segment the iris and eyebrow regions and automatically measure seven landmarks: MRD1, MRD2, medial eyebrow end, medial limbus, pupil center, lateral limbus, and lateral eyebrow end. Results: The iris segmentation model achieved accuracy of 99.7%, precision of 97.6%, recall of 98.3%, an F1 score of 97.9%, and intersection over union of 95.9%. The corresponding metrics for the eyebrow segmentation model were 98.6%, 92.6%, 91.5%, 91.5%, and 85.0%. The mean absolute percentage error and root mean square error for the automated landmark measurements were 4.00% and 2.48 mm, respectively. Conclusions: The high performance of the segmentation models and the automated measurements supports their potential use for objective and standardized analyses of acquired ptosis. These findings may aid the future development of predictive tools for use in surgical planning.
Keywords: deep learning; image segmentation; eyebrows; iris; ptosis deep learning; image segmentation; eyebrows; iris; ptosis

Share and Cite

MDPI and ACS Style

Yoo, D.; Shin, H.J. Deep-Learning Model for Iris and Eyebrow Segmentation and Automation of Eye Landmark Measurements in Acquired Ptosis. Biomedicines 2025, 13, 2557. https://doi.org/10.3390/biomedicines13102557

AMA Style

Yoo D, Shin HJ. Deep-Learning Model for Iris and Eyebrow Segmentation and Automation of Eye Landmark Measurements in Acquired Ptosis. Biomedicines. 2025; 13(10):2557. https://doi.org/10.3390/biomedicines13102557

Chicago/Turabian Style

Yoo, Dain, and Hyun Jin Shin. 2025. "Deep-Learning Model for Iris and Eyebrow Segmentation and Automation of Eye Landmark Measurements in Acquired Ptosis" Biomedicines 13, no. 10: 2557. https://doi.org/10.3390/biomedicines13102557

APA Style

Yoo, D., & Shin, H. J. (2025). Deep-Learning Model for Iris and Eyebrow Segmentation and Automation of Eye Landmark Measurements in Acquired Ptosis. Biomedicines, 13(10), 2557. https://doi.org/10.3390/biomedicines13102557

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Article metric data becomes available approximately 24 hours after publication online.
Back to TopTop