Next Article in Journal
Validity, Reliability, and Cultural Adaptability of the Arabic Cognitive Flexibility Scale (Ar-CFS) Among Saudi Arabians: A Two-Cohort Investigation
Previous Article in Journal
A Solution to Reduce the Impact of Patients’ No-Show Behavior on Hospital Operating Costs: Artificial Intelligence-Based Appointment System
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Evaluating Seismocardiography as a Non-Exercise Method for Estimating Maximal Oxygen Uptake

1
Department of Sports and Exercise Medicine, Institute of Human Movement Science, University of Hamburg, 20148 Hamburg, Germany
2
Institute for Occupational and Maritime Medicine Hamburg (ZfAM), University Medical Center Hamburg-Eppendorf (UKE), 20251 Hamburg, Germany
3
Department of Health Science and Technology, Aalborg University, 9220 Aalborg Øst, Denmark
*
Author to whom correspondence should be addressed.
Healthcare 2024, 12(21), 2162; https://doi.org/10.3390/healthcare12212162
Submission received: 28 June 2024 / Revised: 7 October 2024 / Accepted: 18 October 2024 / Published: 30 October 2024

Abstract

:
Background: The value of maximal oxygen uptake (VO2MAX) is a key health indicator. Usually, VO2MAX is determined with cardiopulmonary exercise testing (CPET), which is cumbersome and time-consuming, making it impractical in many testing scenarios. The aim of this study is to validate a novel seismocardiography sensor (Seismofit®, VentriJect DK, Hellerup, Denmark) for non-exercise estimation of VO2MAX. Methods: A cohort of 94 healthy subjects (52% females, 48.2 (8.7) years old) were included in this study. All subjects performed an ergometer CPET. Seismofit® measurements were obtained 10 and 5 min before CPET in resting condition and 5 min after exhaustion. Results: The CPET VO2MAX was 37.2 (8.6) mL/min/kg, which was not different from the two first Seismofit® estimates at 37.5 (8.1) mL/min/kg (p = 0.28) and 37.3 (7.8) mL/min/kg (p = 0.66). Post-exercise Seismofit® was 33.8 (7.1) mL/min/kg (p < 0.001). The correlation between the CPET and the Seismofit® was r = 0.834 and r = 0.832 for the two first estimates, and the mean average percentage error was 11.4% and 11.2%. Intraclass correlation coefficients between the first and second Seismofit® measurement was 0.993, indicating excellent test-retest reliability. Conclusion: The novel Seismofit® VO2MAX estimate correlates well with CPET VO2MAX, and the accuracy is acceptable for general health assessment. The repeatability of Seismofit® estimates obtained at rest was very high.

1. Introduction

The value of maximal oxygen uptake (VO2MAX) in the fields of cardiorespiratory fitness (CRF), health, disease, and exercise science has been established through numerous investigations and is a very important term in sports medicine. In exercise physiology, peak oxygen consumption (VO2PEAK) is an important term, which connects the interplay between the pulmonary, cardiovascular, and muscular systems in transporting oxygen from the atmosphere to the working muscles [1]. Multiple studies over the past 3 decades have shown increasing evidence that low levels of CRF are associated with a high risk of cardiovascular disease (CVD) and higher mortality. Recent studies have demonstrated that a low fitness level carries a higher risk than any other cardiac risk factors such as smoking, diabetes, hypertension, known cardiac disease, atrial fibrillation, and chronic kidney disease [2]. Furthermore, lower CRF levels are related to various cancers, especially of the breast and the digestive tract [3,4,5,6]. The encouraging results are that even moderate improvement in fitness leads to significant mortality reduction [7]. Echoing these statements, in 2016 the American Heart Association (AHA) declared that CRF is important for CVD risk prediction [8]. It can be concluded that increased CRF by itself leads to both reduced mortality and reduced morbidity.
This underscores the crucial role fitness plays in contemporary health and medical practices, which was underlined in the editorial by Kaminsky et al. in the Journal of the American College of Cardiology, which encouraged both clinicians and public health professionals to adopt CRF as a key health indicator [9]. Traditionally, VO2MAX is ascertained using ‘Cardiopulmonary Exercise Testing’ (CPET) combined with spiroergometry, carried out under maximum exhaustion in diagnostic laboratories. However, this method is laborious and time-intensive, rendering it less feasible for numerous testing situations.
Seismocardiography (SCG) is an emerging non-invasive technology that measures cardiac function from cardiac-induced vibrations at the chest wall, using an accelerometer [10,11]. Multiple studies have linked the SCG signal to cardiac function [12,13]. It is well-established that the heart’s maximal cardiac output is the dominating component of VO2MAX [14]. Sørensen et al. described a correlation between resting SCG measures and VO2MAX [15], and Hansen et al. validated early-stage prototypes for a non-exercise SCG-based VO2MAX estimation [16].
A non-exercise method for estimating CRF could lower the barriers related to CRF estimation in clinical settings and thus utilize CRF as a common clinical biomarker. Therefore, this study aims to evaluate the Seismofit® (VentriJect DK), a novel medical device that employs SCG to estimate VO2MAX, by comparing its results to those derived from a cycle ergometer CPET. In addition, we test the repeatability and robustness of the device and compare it to other CRF estimation methods.

2. Methods

A heterogeneous group of 107 healthy subjects was recruited for this study. To be able to conduct sub-group analyses, we aimed to recruit at least 90 subjects. Exclusion criteria were the following: Chronic diseases in general, high blood pressure (≥130/90), orthopaedic pre-existing conditions, acute illness, and pre-exhaustion failure of the spiroergometry as defined below. Beforehand, subjects were asked to do no more than light physical exertion in the 2 days before the CPET. On the day of the test itself, any physical activity should have been avoided. Furthermore, all participants underwent a medical examination prior to the CPET, a medical history was taken of any pre-existing conditions and medication taken, it was determined how much regular endurance sport is practised, their daily weight and height were measured, and a resting ECG was written. To minimize anxiety, the test procedures were explained adequately, and the test environment was calm and private. The CPET took place in an exercise physiology laboratory at the Faculty of Human Movement Science, University of Hamburg.
The study protocol was approved by the local scientific ethical committee. Subjects signed a written informed consent before participating in the study, and the study complies with the Declaration of Helsinki.

2.1. Cardiopulmonary Exercise Testing

Participants performed an incremental ramp protocol (RAMP Test) until voluntary exhaustion on a mechanically braked cycle (Ergoselect 4 SN, Ergoline GmbH, Bitz, Germany). After initial 3 min at 50 Watts (W), the cycling power consistently increased by 1 W every 3.6 s (equivalent to 50 W/3 min). After termination of the CPET, the protocol provided a 3-min cool-down phase on the cycle ergometer at a load of 50 watts. Michalik et al. described the RAMP Test (~0.277 W/s) compared to the STEP Test (50 W/min) to determine VO2MAX, peak power output, and ventilatory thresholds more precisely [17].
ECG was recorded continuously (12-channel ECG CardioPart 12 Blue) with a sampling rate of 500 Hz (AMEDTEC Medizintechnik Aue GmbH, Aue, Germany) using a desktop software (AMEDTEC ECGpro version 5.10.002). Gas exchange kinetics were recorded with a metabolic analyser in breath-by-breath mode (Quark CPET, module A-67-100-02, COSMED Germany GmbH, Fridolfing, Germany; desktop software: Omnia version 1.6.5). The breath-by-breath method measures the flow, the oxygen concentration, and carbon dioxide concentration time dependently with gas analyzers with a typical frequency (100 Hz) much higher than the maximum breathing frequency (~1 Hz).
Gas calibration of the Quark CPET was carried out before each test according to the manufacturer’s instructions for use. Spiroergometric tests of the individual subjects were conducted at different times and at different room temperatures due to the laboratory capacity and availability of the subjects. We ensured to follow the guidelines recommended by the manufacturer. All measurements have been carried out in accordance with the manufacturer’s instructions at a temperature range of 10 °C to 40 °C. Additionally, sufficient room ventilation was ensured at all times to avoid any measurement errors regarding gas analyses.
Regarding the ACSM (American College of Sports Medicine) guidelines [18], the protocol was terminated when: (A) the subject could not hold the predetermined cadence (60 rpm), (B) the subject reached the Top level of the Borg Rating of Perceived Exertion Scale [19], or (C) due to self-determination. Exhaustion was assumed when the following criteria were fulfilled: (A) heart rate > 90% of the maximum predicted heart rate (prediction model according to Tanaka et al. [20]: 208 − (0.7 × age), and (B) respiratory quotient > 1.05. Maximum oxygen uptake (VO2MAX) and maximum HR (HRMAX) were defined as the average VO2 and HR over the last 30 s of the test.

2.2. Seismocardiography Measurements

The Seismofit® device is a small accelerometer sensor (50 mm × 30 mm × 15 mm) that is controlled by a smartphone app. We conducted measurements using the Seismofit® device at three time points: 10 min and 5 min prior to spiroergometry under resting conditions, and to quantify the influence of non-resting conditions 5 min after exhaustion (Figure 1). The Seismofit® sensor was positioned at the lower sternum using a double adhesive patch (Figure 2) and the recording time was 42 s, while the subject was in a supine position. A smartphone app was utilized to control the Seismofit® sensor, and the recorded seismocardiography (SCG) data were automatically transmitted to a cloud server for processing.
The processing of SCG recordings was performed by VentriJect DK using algorithm version 4.7 [21]. VentriJect was blinded to the spiroergometric results of the current study. The algorithm employed the ensemble average SCG heartbeat (see Figure 2) and employed machine learning techniques to estimate VO2MAX from the SCG beat, in combination with anthropometric data, gender, age, height, and weight. The regression Equation (1) includes four SCG-derived measures: frequency of the systolic SCG complex quantified using principal component analysis (SysSpectrum), the morphology of the diastolic SCG complex quantified using principal component analysis (DiaMorphology), peak to peak amplitude of the average SCG diastolic complex (DiaPeak to Peak), and the heartbeat duration (RR):
V O 2 m a x ~ ω 0 + ω 1   S e x + ω 2   A g e + ω 3 W e i g h t + ω 4 H e i g h t + ω 5 R R + ω 6 D i a P e a k   t o   P e a k + ω 7   D i a M o r p h o l o g y + ω 8   S y s S p e c t r u m
DiaMorphology and DiaPeak to Peak quantify the heart’s diastolic function. Agam et al. demonstrated that DiaPeak to Peak correlated to the echocardiographic e’ parameter, which is related to diastolic filling [22]. SysSpectrum aims at quantifying the heart’s contractability. Sørensen et al. demonstrated the systolic SCG complexes is altered by bi-ventricular pacing. The correlation between the individual equation compotes and VO2MAX is found in Table A1 in Appendix A.

2.3. Benchmarking Against Other Methods

We compared the performance of the Seismofit® to the non-exercise algorithm from the FRIENDS study [23]:
VO2max ~ 79.9 − (0.39 × age) − (13.7 × sex [0 = men; 1 = women]) − (0.127 × weight [lbs])
In addition, we compared to the ACSM metabolic equation where VO2MAX is estimated from the peak power output [18]:
VO2max ~ 10.8 × Peak Power Output/Weight + 7

2.4. Statistical Analysis

Variables were expressed as mean (standard deviation), while categorical variables were reported as frequencies (percentages). Paired Student’s t-tests were used for comparisons between VO2MAX estimates, and Pearson’s tests were used to analyze correlations between variables. All continuous variables were validated as approximately normally distributed via visual analysis. The interpretation of Pearson correlation coefficients followed the classification: very high (>0.90), high (0.70–0.90), moderate (0.50–0.70), low (0.30–0.50), and irrelevant (0.00–0.30) [24].
Estimation error was assessed using the mean average percentage error (MAPE) and standard error of estimate (SEE). Bias, SEE, and MAPE were expressed with their respective [95% confidence intervals]. Repeatability was measured using intraclass correlation coefficients (ICC) with absolute agreement, MAPE, and root mean square (RMS) of the difference between the scores. The Steiger method was employed to test for differences between two correlation coefficients [25]. Additionally, a paired t-test of average percentage errors was conducted to assess statistical significance between MAPE values of different scores.
For detailed analyses of specific subgroups, separate analyses were performed for males and females, adults younger or older than 50 years, recreational physically active (exercising for more than 5 h per week), or sedentary subjects, and subgroups classified by BMI (BMI < 25 kg/m2: normal weight, BMI 25 to 29.9 kg/m2: overweight, BMI ≥ 30 kg/m2: obese). Additionally, subgroups were classified based on VO2MAX levels as follows: low fitness level (VO2MAX < 30 mL/kg/min), moderate fitness level (VO2MAX 30 to 44.9 mL/kg/min), and high fitness level (VO2MAX ≥ 45 mL/kg/min).

3. Results

A heterogeneous group of 107 healthy subjects was recruited for this study. Afterwards, 11 subjects of this study population were excluded due to the premature termination of spiroergometry, and two subjects were excluded since the battery level at the device was too low to obtain either of the Seismofit® recordings. The remaining 94 subjects were 52.1% females, 48.2 (8.7) years old, with a BMI of 24.7(3.6) kg/m2 and 50% with an active lifestyle, Table 1. The CPET VO2MAX was 37.2 (8.6) mL/min/kg, which was 14.5% higher than the VO2MAX of 32.5 (6.8) mL/min/kg predicted by the non-exercise algorithm from the FRIENDS study, indicating that the subjects were slightly fitter than the background population. After the exclusion of the subjects with premature termination of spiroergometry, the correlation between max watt and unadjusted VO2max was very good (r = 0.947), validating the quality of the CPET measurement.

3.1. Seismocardiographic Estimation of VO2MAX

The first Seismofit® measurements were successfully obtained in 93 out of the 94 subjects, and the second Seismofit® measurements were also successfully obtained in 93 out of the 94 subjects. Post-exercise Seismofit® measurements were obtained in 92 subjects. The reason for not obtaining Seismofit® measurements was low device battery power.
The first pre-exercise Seismofit® measurement yielded a value of 37.5 (8.1) mL/min/kg, and the second Seismofit® measurement yielded a value of 37.3 (7.8) mL/min/kg (see Table 1 and Figure 3). However, neither the first nor the second Seismofit® measurements showed a significant difference compared to the CPET VO2MAX at 37.2 (8.6) mL/min/kg (p = 0.64 and p = 0.96, respectively). The average of the two first Seismofit® measurements was 37.4 (8.0) mL/min/kg.
After exercise, the Seismofit® score dropped to 33.8 (7.1) mL/min/kg, which was significantly different from both the pre-exhausting Seismofit® estimates and the CPET estimate (p < 0.001).
The correlation between the CPET and the Seismofit® measurements was high; with r = 0.834 [0.76, 0.89] for the average estimate, r = 0.832 [0.76, 0.89] for the first measurement, r = 0.826 [0.75, 0.88] for the second measurement, and r = 0.769 [0.67, 0.84] for the post-exercise measurement, Table 2 and Figure 4. MAPE was 11.4% [9.74, 13] for the first estimate, 11.2% [9.59, 12.9] for the second estimate, and 13.8% [12, 15.6] for the post-exercise estimate. The limits of the agreement were −9.3 to 9.8 mL/kg/min in the first measurement and −9.3 to 9.8 mL/kg/min in the second measurement.

3.2. Repeatability

Repeatability was determined by the two subsequent pre-exercise measurements. Intraclass correlation coefficients indicated excellent test-retest reliability between the two first recordings with ICC value at 0.993. MAPE between the first and second recordings was 1.87%, and RMS was 0.93 mL/min/kg.

3.3. Comparison to Other Estimation Methods

The estimation error of the FRIENDS non-exercise VO2MAX estimation algorithm was found to be MAPE 15.2% [13.1, 17.4], which was larger than the error of the pre-exercise Seismofit® estimations (p < 0.001). Additionally, the correlation between the FRIENDS algorithm and CPET was 0.752 [0.65, 0.83], demonstrating inferior performance compared to the Seismofit® (p = 0.003), see Table 2.
On the other hand, the ACSM MaxWatt method showed a higher correlation with CPET, with a correlation coefficient of 0.947 [0.92, 0.96], surpassing that of the Seismofit® (p < 0.001). However, the ACSM MaxWatt method overestimated VO2MAX, with a mean overestimation of 7.1 [6.5, 7.7] ml/min/kg. Consequently, the MAPE for ACSM MaxWatt was 20.6% [18.4, 22.7], which was inferior to that of the Seismofit® (p < 0.001).

3.4. Subgroups Analysis

Subjects with an active lifestyle did have a significantly higher CPET VO2MAX (42.4 (7.1) mL/min/kg) than subjects with a sedentary lifestyle (32.0 (7.1) mL/min/kg) (p < 0.001). This was also observed by the Seismofit®, which estimated VO2MAX significantly higher in subjects with an active lifestyle (41.2 (6.3) mL/min/kg) compared to those with a sedentary lifestyle (33.7 (7.7) mL/min/kg) (p < 0.001), Table 1. However, the Seismofit® tended to overestimate VO2MAX in subjects with a sedentary lifestyle, with a mean overestimation of 1.5 [0.25, 2.8] mL/min/kg, Table 3. Conversely, it tended to underestimate VO2MAX in subjects with an active lifestyle, with a mean underestimation of −1.4 [−2.9, −0.003] ml/min/kg. Similarly, the Seismofit® showed overestimation in subjects with a low fitness level (2.7 [0.78, 4.6] mL/min/kg), corresponding to 10.7%, and underestimation in subjects with a high fitness level VO2MAX (−3.4 [−5.9, −0.89] mL/min/kg), corresponding to −6.7%. When examining the results based on gender, age groups, and weight groups, no significant bias was observed, Table 3.

4. Discussion

VO2MAX is a key health indicator, with a high prognostic value. However, its accessibility remains limited in many health and clinical settings. In this study, we validated the Seismofit®, an innovative device designed to estimate VO2MAX without the need for exercise in both sedentary and active subjects.

4.1. VO2MAX Estimation

The correlation between the Seismofit® and the CPET was high in both the first and second recordings (r = 0.832 & r = 0.826), and no estimation bias was observed. The estimation error (SEE = 4.9 mL/min/kg & MAPE 11.2–11.4%) of the device is acceptable for many applications in health assessment. However, there is no clear definition of what an acceptable estimation error is. Hansen et al. recommended a MAPE < 10% [16], which was not fully met in the current study. Meanwhile, Molina-Garcia et al. from the INETLIVE network [26] argue that clinical tests should be able to detect a change in VO2MAX of 1.75–3.5 mL/min/kg, since clinical studies have demonstrated that an increase of 1.75 to 3.5 mL/min/kg has significant health benefits. It is therefore important that the repeatability of the Seismofit® was very high (ICC = 0.993) with a very low variation between the first and the second measurements (RMS = 0.93 mL/min/kg). The trade-off between the more accurate CPET test and more feasible VO2MAX estimation methods like the Seismofit® depends on multiple factors. These include the availability of CPET equipment, whether the subject can exercise to exhaustion, safety concerns, and the time and resources available for testing.
Compared to the prior prototype algorithm version 4.3 reported by Hansen et al., the current algorithm version 4.7 had a higher correlation (r = 0.832 & r = 0.826 vs. r = 0.73) and a lower estimation error (SEE = 4.9 mL/min/kg vs. SEE = 5.9 mL/min/kg).

4.2. Comparison to State-of-the-Art Estimation Methods

The Seismofit® was superior to the non-exercise algorithm from the FRIENDS study, in both correlation and estimation error. In comparison with other non-exercise VO2MAX tests described in the scientific literature, such as wearable watches, the estimation error of the Seismofit® was also substantially lower. Molina-Garcia et al. reported that the limits of agreement of non-exercise watches were −13.97 to 17.41 mL/kg/min, while the limits of agreement of the first Seismofit® recording were −9.3 to 9.8 mL/kg/min, positioning the Seismofit® as potentially the most accurate non-exercise estimation method.
The correlation between the ACSM MaxWatt method and the CPET was higher than the correlation between the Seismofit® and the CPET, but the ACSM equation overestimated VO2MAX with 7.1 mL/min/kg, leading to a high estimation error at 20.6% MAPE. However, if this systematic error is accounted for and exercise to exhaustion is feasible, the MaxWatt method can provide more accurate estimates of VO2MAX than the current Seismofit® method.
An alternative to MaxWatt tests is the sub-maximal test, which requires some level of exercise. Here, the heart rate at one or two load levels of exercise is used to extrapolate to a VO2MAX. Commonly used tests are the Aastrand and the YMCA test. Beekley et al. validated the YMCA test and found a correlation at r = 0.79 between ergometer CPET and the YMCA estimate [27]. Their measure of total error corresponds to our SEE measure. The total error of the estimate of the YMCA test was 18.5 mL/min/kg, which is considerably higher than the SEE of Seismofit® at 4.9 mL/min/kg. Similar performance was identified for the Aastrand test with r = 0.71–0.78 and SSE 6.2–9.7 mL/min/kg [28].

4.3. Use of the Seismofit®

The Seismofit® offers a swift, straightforward, and objective method for estimating VO2MAX with notable accuracy. This could ease access to VO2MAX during health evaluations, lifestyle interventions, risk assessments, and the monitoring of athletic performance.
In our study, we found no significant variance in estimation error across gender, weight categories, or age groups. This suggests that the Seismofit® has a broad application scope within a generally healthy demographic. The Seismofit® distinctly estimated higher VO2MAX values in active subjects compared to their sedentary counterparts, illustrating its capability to discern between the effects of different lifestyles. However, the data also indicates that the Seismofit® tends to underestimate VO2MAX in high-fitness-level individuals and individuals with active lifestyles and overestimate it in those with a low-fitness-level VO2MAX and a sedentary lifestyle. Further model developments should focus on improving estimation accuracy, especially for individuals with sedentary lifestyles who can’t perform graded exercise testing. These individuals might have the largest benefit of cardiovascular risk estimation.
Post-exercise, the Seismofit® estimates were lower than the two pre-exercise estimates (33.8 mL/min/kg vs. 37.4 mL/min/kg). This suggests that the optimal time to gauge VO2MAX using the Seismofit® is when the individual is at rest and relaxed. Consequently, we do not recommend using the Seismofit® to estimate VO2MAX immediately after physical exertion, as this can skew the results.

4.4. Study Limitations

One significant limitation of this study is that 11 subjects did not reach exhaustion and were consequently excluded from the analysis. Reasons for not reaching the maximum load were failure of the CPET equipment, software failure, muscular cramps, anxiety, sudden pain events, not reaching a heart rate > 90% of the maximum predicted heart rate (prediction model according to Tanaka et al. [20]: 208 − (0.7 × age), or a respiratory quotient < 1.05. Furthermore, we excluded individuals based on several criteria: the presence of chronic diseases, hypertension, orthopaedic pre-existing conditions, and acute illnesses. This restricts our findings primarily to populations without these diagnoses. It is also important to note that since Seismofit® estimates are derived from cardiac signal analysis, the respiratory and metabolic components of VO2MAX are not considered in the Seismofit® estimation. Last, the various CPET measurements were not carried out under exactly the same laboratory conditions. At least they differed in time of day, temperature, and humidity. In addition, there was no further CPET testing to validate and refer the measured VO2MAX values.

4.5. Study Strength and Further Studies

The strength of this study lies in the validation of the Seismofit® within a heterogeneous healthy population, encompassing a wide age span and individuals with varying levels of activity and fitness. Future research should focus on validating this tool in specific patient groups, such as cardiac patients and those undergoing major surgery or cancer treatment, who could benefit from VO2MAX estimation for clinical treatment planning.

5. Conclusions

The Seismofit® presents a novel and reliable approach to estimating VO2MAX without exercise. This innovative method can potentially pave the way for broader utilization of VO2MAX as a key health indicator. Further research should focus on model calibration and validation for subjects with very poor fitness levels where the capability to perform graded exercise testing is very limited.

Author Contributions

Conceptualization, J.S. and R.R.; Data curation, R.S. and S.E.S.; Formal analysis, R.S., S.E.S., J.S. and R.R.; Investigation, R.S.; Methodology, S.E.S.; Project administration, R.R.; Software, S.E.S.; Supervision, S.E.S., J.S., V.H. and R.R.; Visualization, S.E.S.; Writing—original draft, R.S. and S.E.S. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by VentriJect Aps (DK).

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki and approved by the Local Ethics Committee of the Faculty of Psychology and Movement Science, University of Hamburg, Germany (13 October 2023, protocol code: 2023_055). The Local Ethics Committee of the Faculty of Psychology and Human Movement Science at the University of Hamburg is an independent body, which examines the ethical and legal admissibility of psychological research project in psychology and human movement science before they are carried out. The Local Ethic Committee consists of eight professors, three representatives of the mid-level faculty, and three students, who represent the various fields of study at the Faculty of Psychology and Human Movement Sciences.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

The data presented in this study are available on request from the corresponding author due to privacy and data protection.

Acknowledgments

We would like to thank all the participants for their commitment and participation in the study. We thank VentriJect Aps for the assistance with equipment and data acquisition regarding the SCG VO2MAX prediction.

Conflicts of Interest

The authors declare that SES has significant shares in VentriJect Aps and works part-time as Chief Scientific Officer in VentriJect Aps in the past 3 years, respectively. The authors declare that the study has been carried out objectively without any other intention beyond reporting to science a device that may be valuable for the estimation of maximal oxygen uptake.

Appendix A

Table A1. Correlation between the variables included in the Seismofit® estimation algorithm and VO2MAX.
Table A1. Correlation between the variables included in the Seismofit® estimation algorithm and VO2MAX.
AllMaleFemale
Pre-exercise 1. measurement
Sex (Male = 1)0.49
Age (Years)−0.314−0.409−0.374
Weight (kg)−0.177−0.607−0.549
Height (cm)0.357−0.07040.12
RR (s)0.4210.2730.412
DiaPeak to Peak0.4230.5850.58
SysSpectrum0.3710.4140.456
DiaMorphology0.6030.4860.317
Pre-exercise 2. measurement
Sex (Male = 1)0.47
Age (Years)−0.321−0.43−0.377
Weight (kg)−0.188−0.595−0.555
Height (cm)0.341−0.08690.12
RR (s)0.3040.1810.344
DiaPeak to Peak0.4420.590.61
SysSpectrum0.3970.50.446
DiaMorphology0.5770.4420.29
Post-exercise measurement
Sex (Male = 1)0.43
Age (Years)−0.299−0.429−0.356
Weight (kg)−0.193−0.597−0.569
Height (cm)0.338−0.09560.25
RR (s)0.03310.04720.0558
DiaPeak to Peak0.1650.4120.457
SysSpectrum0.310.3890.371
DiaMorphology0.4930.1790.394

References

  1. Wasserman, K.; Van Kessel, A.L.; Burton, G.G. Interaction of Physiological Mechanisms during Exercise. J. Appl. Physiol. 1967, 22, 71–85. [Google Scholar] [CrossRef] [PubMed]
  2. Kokkinos, P.; Faselis, C.; Samuel, I.B.H.; Pittaras, A.; Doumas, M.; Murphy, R.; Heimall, M.S.; Sui, X.; Zhang, J.; Myers, J. Cardiorespiratory Fitness and Mortality Risk Across the Spectra of Age, Race, and Sex. J. Am. Coll. Cardiol. 2022, 80, 598–609. [Google Scholar] [CrossRef] [PubMed]
  3. Laukkanen, J.A.; Kurl, S.; Salonen, R.; Rauramaa, R.; Salonen, J.T. The Predictive Value of Cardiorespiratory Fitness for Cardiovascular Events in Men with Various Risk Profiles: A Prospective Population-Based Cohort Study. Eur. Heart J. 2004, 25, 1428–1437. [Google Scholar] [CrossRef]
  4. Blair, S.N.; Kohl, H.W.; Paffenbarger, R.S.; Clark, D.G.; Cooper, K.H.; Gibbons, L.W. Physical Fitness and All-Cause Mortality. A Prospective Study of Healthy Men and Women. JAMA 1989, 262, 2395–2401. [Google Scholar] [CrossRef] [PubMed]
  5. Sui, X.; LaMonte, M.J.; Blair, S.N. Cardiorespiratory Fitness as a Predictor of Nonfatal Cardiovascular Events in Asymptomatic Women and Men. Am. J. Epidemiol. 2007, 165, 1413–1423. [Google Scholar] [CrossRef]
  6. Sawada, S.S.; Lee, I.-M.; Naito, H.; Kakigi, R.; Goto, S.; Kanazawa, M.; Okamoto, T.; Tsukamoto, K.; Muto, T.; Tanaka, H.; et al. Cardiorespiratory Fitness, Body Mass Index, and Cancer Mortality: A Cohort Study of Japanese Men. BMC Public Health 2014, 14, 1012. [Google Scholar] [CrossRef]
  7. Kokkinos, P.; Faselis, C.; Samuel, I.B.H.; Lavie, C.J.; Zhang, J.; Vargas, J.D.; Pittaras, A.; Doumas, M.; Karasik, P.; Moore, H.; et al. Changes in Cardiorespiratory Fitness and Survival in Patients With or Without Cardiovascular Disease. J. Am. Coll. Cardiol. 2023, 81, 1137–1147. [Google Scholar] [CrossRef]
  8. Ross, R.; Blair, S.N.; Arena, R.; Church, T.S.; Després, J.-P.; Franklin, B.A.; Haskell, W.L.; Kaminsky, L.A.; Levine, B.D.; Lavie, C.J.; et al. Importance of Assessing Cardiorespiratory Fitness in Clinical Practice: A Case for Fitness as a Clinical Vital Sign: A Scientific Statement from the American Heart Association. Circulation 2016, 134, e653–e699. [Google Scholar] [CrossRef]
  9. Kaminsky, L.A.; Imboden, M.T.; Ozemek, C. It’s Time to (Again) Recognize the Considerable Clinical and Public Health Significance of Cardiorespiratory Fitness. J. Am. Coll. Cardiol. 2023, 81, 1148–1150. [Google Scholar] [CrossRef]
  10. Taebi, A.; Solar, B.E.; Bomar, A.J.; Sandler, R.H.; Mansy, H.A. Recent Advances in Seismocardiography. Vibration 2019, 2, 64–86. [Google Scholar] [CrossRef]
  11. Zanetti, J.M.; Tavakolian, K. Seismocardiography: Past, Present and Future. In Proceedings of the 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Osaka, Japan, 3–7 July 2013; pp. 7004–7007. [Google Scholar] [CrossRef]
  12. Ganti, V.G.; Gazi, A.H.; An, S.; Srivatsa, A.V.; Nevius, B.N.; Nichols, C.J.; Carek, A.M.; Fares, M.; Abdulkarim, M.; Hussain, T.; et al. Wearable Seismocardiography-Based Assessment of Stroke Volume in Congenital Heart Disease. J. Am. Heart Assoc. 2022, 11, e026067. [Google Scholar] [CrossRef] [PubMed]
  13. Herkert, C.; Migeotte, P.-F.; Hossein, A.; Spee, R.F.; Kemps, H.M.C. The Kinocardiograph for Assessment of Changes in Haemodynamic Load in Patients with Chronic Heart Failure with Reduced Ejection Fraction. ESC Heart Fail. 2021, 8, 4925–4932. [Google Scholar] [CrossRef] [PubMed]
  14. Levine, B.D. VO2MAX: What Do We Know, and What Do We Still Need to Know? J. Physiol. 2008, 586, 25–34. [Google Scholar] [CrossRef] [PubMed]
  15. Sørensen, K.; Poulsen, M.K.; Karbing, D.S.; Søgaard, P.; Struijk, J.J.; Schmidt, S.E. A Clinical Method for Estimation of VO2MAX Using Seismocardiography. Int. J. Sports Med. 2020, 41, 661–668. [Google Scholar] [CrossRef] [PubMed]
  16. Hansen, M.T.; Grønfeldt, B.M.; Rømer, T.; Fogelstrøm, M.; Sørensen, K.; Schmidt, S.E.; Helge, J.W. Determination of Maximal Oxygen Uptake Using Seismocardiography at Rest. In Proceedings of the 2021 Computing in Cardiology (CinC), Brno, Czech Republic, 13–15 September 2021; IEEE: New York, NY, USA, 2021; Volume 48, pp. 1–4. [Google Scholar]
  17. Michalik, K.; Danek, N.; Zatoń, M. Assesment of the physical fitness of road cyclists in the step and ramp protocols of the incremental test. J. Sports Med. Phys. Fit. 2019, 59, 1285–1291. [Google Scholar] [CrossRef]
  18. American College of Sports Medicine; Pescatello, L.S. ACSM’s Guidelines for Exercise Testing and Prescription, 9th ed.; Wolters Kluwer/Lippincott Williams & Wilkins Health Philadelphia: Philadelphia, PA, USA, 2014; ISBN 978-1-60913-605-5. [Google Scholar]
  19. Borg, G. Borg’s Perceived Exertion and Pain Scales, 1st ed.; Human Kinetics: Champaign, IL, USA, 1998. [Google Scholar]
  20. Tanaka, H.; Monahan, K.D.; Seals, D.R. Age-Predicted Maximal Heart Rate Revisited. J. Am. Coll. Cardiol. 2001, 37, 153–156. [Google Scholar] [CrossRef]
  21. Schmidt, S.E.; Hansen, M.T.; Rømer, T.; Soegaard, P.; Helge, J.W. Estimation of Cardiorespiratory Fitness Using a Chest Mounted Accelerometer. Eur. Heart J.-Digit. Health 2022, 3, ztac076-2769. [Google Scholar]
  22. Agam, A.; Søgaard, P.; Kragholm, K.; Jensen, A.S.; Sørensen, K.; Hansen, J.; Schmidt, S. Correlation between Diastolic Seismocardiography Variables and Echocardiography Variables. Eur. Heart J. Digit. Health 2022, 3, 465–472. [Google Scholar] [CrossRef]
  23. Kaminsky, L.A.; Imboden, M.T.; Arena, R.; Myers, J. Reference Standards for Cardiorespiratory Fitness Measured With Cardiopulmonary Exercise Testing Using Cycle Ergometry: Data From the Fitness Registry and the Importance of Exercise National Database (FRIEND) Registry. Mayo Clin. Proc. 2017, 92, 228–233. [Google Scholar] [CrossRef]
  24. Hinkle, D.E.; Wiersma, W.; Jurs, S.G. Applied Statistics for the Behavioral Sciences, 5th ed.; Houghton Mifflin Co.: Boston, MA, USA; London, UK, 2003. [Google Scholar]
  25. Steiger, J.H. Tests for Comparing Elements of a Correlation Matrix. Psychol. Bull. 1980, 87, 245–251. [Google Scholar] [CrossRef]
  26. Molina-Garcia, P.; Notbohm, H.L.; Schumann, M.; Argent, R.; Hetherington-Rauth, M.; Stang, J.; Bloch, W.; Cheng, S.; Ekelund, U.; Sardinha, L.B.; et al. Validity of Estimating the Maximal Oxygen Consumption by Consumer Wearables: A Systematic Review with Meta-Analysis and Expert Statement of the INTERLIVE Network. Sport. Med. Auckl. NZ 2022, 52, 1577–1597. [Google Scholar] [CrossRef] [PubMed]
  27. Beekley, M.D.; Brechue, W.F.; Dehoyos, D.V.; Garzarella, L.; Werber-Zion, G.; Pollock, M.L. Cross-Validation of the YMCA Submaximal Cycle Ergometer Test to Predict VO2MAX. Res. Q. Exerc. Sport 2004, 75, 337–342. [Google Scholar] [CrossRef] [PubMed]
  28. Jackson, A.S.; Blair, S.N.; Mahar, M.T.; Wier, L.T.; Ross, R.M.; Stuteville, J.E. Prediction of Functional Aerobic Capacity without Exercise Testing. Med. Sci. Sports Exerc. 1990, 22, 863–870. [Google Scholar] [CrossRef] [PubMed]
Figure 1. The study protocol. After enrolment two Seismofit® recordings were obtained with 5-min intervals before the CPEP test. A third Seismofit® recording was obtained 5 min after the CPET test.
Figure 1. The study protocol. After enrolment two Seismofit® recordings were obtained with 5-min intervals before the CPEP test. A third Seismofit® recording was obtained 5 min after the CPET test.
Healthcare 12 02162 g001
Figure 2. Left: The Seismofit® mounted at the lower sternum in supine position. Right: Ensemble average SCG’s from three males with different spirometry VO2MAX levels.
Figure 2. Left: The Seismofit® mounted at the lower sternum in supine position. Right: Ensemble average SCG’s from three males with different spirometry VO2MAX levels.
Healthcare 12 02162 g002
Figure 3. Vilon plot of the VO2MAX values estimated by Seismofit® and CPET. The white circle represents means. Seismofit® and Scatter plots of Seismofit® and CPET VO2MAX from the first and second Seismofit® measurements prior to exercise and the third measurement post-exercise.
Figure 3. Vilon plot of the VO2MAX values estimated by Seismofit® and CPET. The white circle represents means. Seismofit® and Scatter plots of Seismofit® and CPET VO2MAX from the first and second Seismofit® measurements prior to exercise and the third measurement post-exercise.
Healthcare 12 02162 g003
Figure 4. Top row: Scatter and Bland Altman plots between Seismofit® and CPET VO2MAX from the first and second Seismofit® measurement prior to exercise and the third measurement post exercise. Bottom row: Bland Altman plots including 95% lines of agreement.
Figure 4. Top row: Scatter and Bland Altman plots between Seismofit® and CPET VO2MAX from the first and second Seismofit® measurement prior to exercise and the third measurement post exercise. Bottom row: Bland Altman plots including 95% lines of agreement.
Healthcare 12 02162 g004
Table 1. Baseline characteristics of included subjects.
Table 1. Baseline characteristics of included subjects.
AllSedentary
Lifestyle
Active
Lifestyle
n944747
Female sex (p = 0.063)49 (52.1%)29 (61.7%)20 (42.6%)
Age (years) (p = 0.43)48.2 (8.7)48.9 (9.7)47.5 (7.6)
Height (m) (p = 0.081)1.8 (0.08)1.7 (0.09)1.8 (0.077)
Weight (kg) (p = 0.04)76.5 (13.9)79.5 (16.1)73.6 (10.7)
BMI (p < 0.001)24.7 (3.6)26.1 (4.1)23.4 (2.2)
Max power (watt) (p < 0.001)260.1 (64.3)231.4 (61.1)288.7 (54.1)
VO2 (mL/min) (p < 0.001)2822.8 (771)2526.4 (755)3119.2 (673)
VO2 per kg Body Weight (ml/min/kg) (p < 0.001)37.2 (8.6)32.0 (7.1)42.4 (6.7)
1. Seismofit® (mL/min/kg) (p < 0.001)37.5 (8.1)33.7 (7.8)41.4 (6.5)
2. Seismofit® (mL/min/kg) (p < 0.001)37.3 (7.8)33.6 (7.6)40.9 (6.22)
Mean 1. & 2. Seismofit® (mL/min/kg) (p < 0.001)37.4 (7.9)33.7 (7.7)41.2 (6.3)
Post exhaustion Seismofit® (mL/min/kg) (p < 0.001)33.8 (7.09)30.9 (7)36.6 (6.03)
FRIENDS study (mL/min/kg) (p < 0.001)32.5 (6.8)30.1 (6.5)34.9 (6.3)
ASCM MaxWatt (mL/min/kg) (p < 0.001)44.2 (8.6)38.8 (7.1)49.7 (6.4)
Heart rate 1. Seismofit® (BPM) (p < 0.001)60.1 (9.3)63.3 (9.6)56.9 (7.8)
Heart rate 2. Seismofit® (BPM) (p = 0.017)60.5 (9.4)62.8 (9.1)58.2 (9.1)
Heart rate Post exhaustion Seismofit® (BPM) (p = 0.44)82.0 (10.5)82.9 (10.2)81.2 (10.8)
Continuous variables mean (SD) and categorical variables n (%). BPM: Beats per minute. Active lifestyle was defined as at least 5 h of exercise per week.
Table 2. Estimation performance of the Seismofit®, FRIENDS Study algorithm, and ACSM MaxWatt algorithm.
Table 2. Estimation performance of the Seismofit®, FRIENDS Study algorithm, and ACSM MaxWatt algorithm.
1. Seismofit®2. Seismofit®Average
1. & 2
Post ex.
Seismofit®
FRIENDS StudyACSM
MaxWatt
n939392919492
MAPE (%)11.4
[9.74, 13%]
11.2
[9.59, 12.9%]
11.1
[9.5, 12.8%]
13.8
[12, 15.6%]
15.2
[13.1, 17.4%]
20.6
[18.4, 22.7%]
r0.832
[0.76, 0.89]
0.826
[0.75, 0.88]
0.834
[0.76, 0.89]
0.769
[0.67, 0.84]
0.752
[0.65, 0.83]
0.947
[0.92, 0.96]
SEE (mL/min/kg)4.94.94.96.67.47.7
Bias (mL/min/kg)0.24
[−0.77, 1.2]
0.024
[−0.99, 1]
0.05
[−0.95, 1.1]
−3.6
[−4.7, −2.4] *
−4.7
[−5.8, −3.5] *
7.1
[6.5, 7.7] *
Upper LoA (mL/min/kg)9.89.79.57.36.512.6
Lower LoA (mL/min/kg)−9.3−9.6−9.4−14.4−15.81.6
Estimated value [95% confidence interval of estimate], n: number of subjects included in the analysis, MAPE: Mean Average Percentage Error, r: Pearson correlation coefficient, SEE: Standard Error of Estimate, LoA: Limits of Agreement. * Bias significantly different from zero.
Table 3. Estimation performance of the Seismofit® in subgroups. Analysis was conducted using the average Seismofit® score.
Table 3. Estimation performance of the Seismofit® in subgroups. Analysis was conducted using the average Seismofit® score.
nBias (mL/min/kg)MAPE (%)rSEE (mL/min/kg)
All920.05 [−0.95, 1.1]11.1 [9.5, 12.8]0.834 [0.76, 0.89]4.9
Activity level
Sedentary lifestyle461.5 [0.25, 2.8] *12.4 [9.66, 15.2]0.831 [0.71, 0.9]4.7
Active lifestyle46−1.4 [−2.9, −0.0026] *9.8 [8.08, 11.6]0.719 [0.54, 0.84]5.1
Sex
Female48−0.4 [−1.7, 0.88]11.0 [8.99, 13.1]0.801 [0.67, 0.88]4.4
Male440.5 [−1.1, 2.1]11.3 [8.57, 13.9]0.748 [0.58, 0.85]5.4
Fitness level (VO2MAX)
Low < 30 mL/kg/min192.7 [0.78, 4.6] *15.2 [9.69, 20.7]0.694 [0.35, 0.87]5.0
Moderate 30–45 mL/kg/min550.3 [−0.93, 1.5]10.0 [8.19, 11.7]0.673 [0.5, 0.8]4.5
Good > 45 mL/kg/min18−3.4 [−5.9, −0.89] *10.4 [7.48, 13.3]0.359 [−0.13, 0.71]6.4
BMI
Normal weight: <25 kg/m259−0.13 [−1.4, 1.1]9.9 [8.34, 11.4]0.788 [0.67, 0.87]4.8
Overweight: 20–29.9 kg/m2270.7 [−1.4, 2.8]13.6 [9.39, 17.9]0.773 [0.56, 0.89]5.4
Obese: ≥30 kg/m26−1.0 [−5.6, 3.5]12.4 [2.87, 21.9]0.865 [0.18, 0.99]5.0
Age
<50 years530.3 [−1.1, 1.7]10.5 [8.4, 12.6]0.794 [0.67, 0.88]5.1
>50 Years39−0.3 [−1.7, 1.2]12 [9.32, 14.7]0.842 [0.72, 0.91]4.6
Estimated value [95% confidence interval of estimate], n: number of subjects included in the analysis, MAPE: Mean Average Percentage Error, r: Pearson correlation coefficient, SEE: Standard Error of Estimate. Active lifestyle was defined as at least 5 h of exercise per week. * Significant bias (p < 0.05).
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Schulenburg, R.; Schmidt, S.E.; Schröder, J.; Harth, V.; Reer, R. Evaluating Seismocardiography as a Non-Exercise Method for Estimating Maximal Oxygen Uptake. Healthcare 2024, 12, 2162. https://doi.org/10.3390/healthcare12212162

AMA Style

Schulenburg R, Schmidt SE, Schröder J, Harth V, Reer R. Evaluating Seismocardiography as a Non-Exercise Method for Estimating Maximal Oxygen Uptake. Healthcare. 2024; 12(21):2162. https://doi.org/10.3390/healthcare12212162

Chicago/Turabian Style

Schulenburg, Robert, Samuel Emil Schmidt, Jan Schröder, Volker Harth, and Rüdiger Reer. 2024. "Evaluating Seismocardiography as a Non-Exercise Method for Estimating Maximal Oxygen Uptake" Healthcare 12, no. 21: 2162. https://doi.org/10.3390/healthcare12212162

APA Style

Schulenburg, R., Schmidt, S. E., Schröder, J., Harth, V., & Reer, R. (2024). Evaluating Seismocardiography as a Non-Exercise Method for Estimating Maximal Oxygen Uptake. Healthcare, 12(21), 2162. https://doi.org/10.3390/healthcare12212162

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop