You are currently viewing a new version of our website. To view the old version click .
Audiology Research
  • Audiology Research is published by MDPI from Volume 10 Issue 2 (2020). Previous articles were published by another publisher in Open Access under a CC-BY (or CC-BY-NC-ND) licence, and they are hosted by MDPI on mdpi.com as a courtesy and upon agreement with PAGEPress.
  • Article
  • Open Access

21 November 2018

Effects of Directional Hearing Aid Settings on Different Laboratory Measures of Spatial Awareness Perception

,
,
,
and
1
Medizinische Physik and Cluster of Excellence “Hearing4all”, Oldenburg University, Oldenburg, Germany
2
HörTech gGmbH, Oldenburg, Germany
3
Eriksholm Research Centre, Snekkersten, Denmark
4
Institute of Clinical Research, University of Southern Denmark, Odense, Denmark

Abstract

Hearing loss can negatively influence the spatial hearing abilities of hearing-impaired listeners, not only in static but also in dynamic auditory environments. Therefore, ways of addressing these deficits with advanced hearing aid algorithms need to be investigated. In a previous study based on virtual acoustics and a computer simulation of different bilateral hearing aid fittings, we investigated auditory source movement detectability in older hearing- impaired (OHI) listeners. We found that two directional processing algorithms could substantially improve the detectability of left-right and near-far source movements in the presence of reverberation and multiple interfering sounds. In the current study, we carried out similar measurements with a loudspeaker-based setup and wearable hearing aids. We fitted a group of 15 OHI listeners with bilateral behind-the-ear devices that were programmed to have three different directional processing settings. Apart from source movement detectability, we assessed two other aspects of spatial awareness perception. Using a street scene with up to five environmental sound sources, the participants had to count the number of presented sources or to indicate the movement direction of a single target signal. The data analyses showed a clear influence of the number of concurrent sound sources and the starting position of the moving target signal on the participants’ performance, but no influence of the different hearing aid settings. Complementary artificial head recordings showed that the acoustic differences between the three hearing aid settings were rather small. Another explanation for the lack of effects of the tested hearing aid settings could be that the simulated street scenario was not sufficiently sensitive. Possible ways of improving the sensitivity of the laboratory measures while maintaining high ecological validity and complexity are discussed.

Article Metrics

Citations

Article Access Statistics

Multiple requests from the same IP address are counted as one view.