The Effect of Denture Cleansing Solutions on the Retention of Precision Attachments: An In Vitro Study
Abstract
:1. Introduction
2. Materials and Methods
3. Results
4. Discussion
5. Conclusions
Author Contributions
Funding
Institutional Review Board Statement
Informed Consent Statement
Data Availability Statement
Conflicts of Interest
References
- Munot, V.K.; Nayakar, R.P.; Patil, R. Prosthetic Rehabilitation of Mandibular Defects with Fixed-removable Partial Denture Prosthesis Using Precision Attachment: A Twin Case Report. Contemp. Clin. Dent. 2017, 8, 473–478. [Google Scholar] [CrossRef] [PubMed]
- Peracini, A.; de Andrade, I.M.; Paranhos, H.; da Silva, C.H.; de Souza, R. Behaviors and hygiene habits of complete denture wearers. Braz. Dent. J. 2010, 21, 247–252. [Google Scholar] [CrossRef] [PubMed]
- Cheatham, J.L.; Newland, J.R.; Radentz, W.H.; O’Brien, R. The ‘fixed’ removable partial denture: Report of case. J. Am. Dent. Assoc. 1984, 109, 57–59. [Google Scholar] [CrossRef] [PubMed]
- Jeyavalan, M.I.; Narasimman, M.; Venkatakrishnan, C.J.; Philip, J.M. Management of long span partially edentulous maxilla with fixed removable denture prosthesis. Contemp. Clin. Dent. 2012, 3, 314–316. [Google Scholar] [CrossRef] [PubMed]
- Jain, A.R. A prosthetic alternative treatment for severe anterior ridge defect using fixed removable partial denture Andrew’s Bar system. World J. Dent. 2013, 4, 282–285. [Google Scholar] [CrossRef]
- Nguyen, C.; Masri, R.; Driscoll, C.F.; Romberg, E. The effect of denture cleansing solutions on the retention of pink Locator attachments: An in vitro study. J. Prosthodont. 2010, 19, 226–230. [Google Scholar] [CrossRef] [PubMed]
- Rutkunas, V.; Mizutani, H.; Takahashi, H. Influence of attachment wear on retention of mandibular overdenture. J. Oral Rehabil. 2007, 34, 41–51. [Google Scholar] [CrossRef]
- Shay, K. Denture hygiene: A review and update. J. Contemp. Dent. Pract. 2000, 1, 28–41. [Google Scholar] [CrossRef]
- Doukas, D.; Michelinakis, G.; Smith, P.W. The influence of interimplant distance and attachment type on the retention characteristics of mandibular overdentures on 2 implants: 6-month fatigue retention values. Int. J. Prosthodont. 2008, 21, 152–154. [Google Scholar]
- Williams, B.H.; Ochiai, K.T.; Hojo, S. Retention of maxillary implant overdenture bars of different designs. J. Prosthet. Dent. 2001, 86, 603–607. [Google Scholar] [CrossRef] [Green Version]
- Bayer, S.; Keilig, L.; Kraus, D.; Gruner, M.; Stark, H.; Mues, S.; Enkling, N. Influence of the lubricant and the alloy on the wear behaviour of attachments. Gerodontology 2011, 28, 221–226. [Google Scholar] [CrossRef] [PubMed]
- Yadav, R.; Yadav, V.S.; Garg, S.; Mittal, S.; Garg, R. Effectiveness of different denture cleansing methods on removal of biofilms formed in vivo. J. Cranio-Max. Dis. 2013, 2, 22–27. [Google Scholar] [CrossRef]
- Kiesow, A.; Sarembe, S.; Pizzey, R.L.; Axe, A.S.; Bradshaw, D.J. Material compatibility and antimicrobial activity of consumer products commonly used to clean dentures. J. Prosthet. Dent. 2016, 115, 189–198. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Dills, S.S.; Olshan, A.M.; Goldner, S. Comparison of the antimicrobial capability of an abrasive paste and chemical-soak denture cleaners. J. Prosthet. Dent. 1988, 60, 467–470. [Google Scholar] [CrossRef]
- Dikbas, I.; Koksal, T.; Calikkocaoglu, S. Investigation of the cleanliness of dentures in a university hospital. Int. J. Prosthodont. 2006, 19, 294–298. [Google Scholar] [PubMed]
- You, W.; Masri, R.; Romberg, E.; Driscoll, C.F.; You, T. The effect of denture cleansing solutions on the retention of pink Locator attachments after multiple pulls: An in vitro study. J. Prosthodont. 2011, 20, 464–469. [Google Scholar] [CrossRef]
- Baran, I.; Nalçaci, R. Self-reported denture hygiene habits and oral tissue conditions of complete denture wearers. Arch. Gerontol. Geriatr. 2009, 49, 237–241. [Google Scholar] [CrossRef]
- Ettinger, R.L.; Jakobsen, J.R. A comparison of patient satisfaction and dentist evaluation of overdenture therapy. Community Dent. Oral Epidemiol. 1997, 25, 223–227. [Google Scholar] [CrossRef]
- McKenna, G.; Allen, P.F.; O’Mahony, D.; Cronin, M.; DaMata, C.; Woods, N. The impact of rehabilitation using removable partial dentures and functionally orientated treatment on oral health-related quality of life: A randomised controlled clinical trial. J. Dent. 2015, 43, 66–71. [Google Scholar] [CrossRef]
- Kürkcüoğlu, I.; Ozkir, S.E.; Köroğlu, A.; Sahin, O.; Yilmaz, B. Effect of denture cleansing solutions on different retentive attachments. J. Prosthet. Dent. 2016, 115, 606–610. [Google Scholar] [CrossRef]
- Sakar, O. Removable Partial Dentures: A Practitioners’ Manual, 1st ed.; Springer: Cham, Switzerland, 2015; pp. 176–179. [Google Scholar]
- Structural Elements Brochure. Available online: https://www.bredent.co.uk/wp-content/uploads/2017/03/Structural-elements.pdf (accessed on 8 March 2022).
- Besimo, C.E.; Guarneri, A. In vitro retention force changes of prefabricated attachments for overdentures. J. Oral Rehabil. 2003, 30, 671–678. [Google Scholar] [CrossRef] [PubMed]
- Breeding, L.; Dixon, D.; Schmitt, S. The effect of simulated function on the retention of bar-clip retained removable prostheses. J. Prosthet. Dent. 1996, 75, 570–573. [Google Scholar] [CrossRef]
- El Mekawy, N.; Algraisi, M.I.; El Shaheed, N.H. In vitro Comparison of Denture Cleansers Effect on Locator Attachment Retentive Male Inserts (Scanning Electron Microscope Study). Oral Health Dent. Manag. 2018, 17, 1–8. [Google Scholar]
Type of the Attachment | Frictional Feature | Number of Specimens | Number of Pulls for Each Attachment |
---|---|---|---|
Yellow bolt attachment | Regular friction-6 N | 32 | 12 |
Green bolt attachment | Reduced friction-4 N | 32 | 12 |
Red bolt attachment | High retention-8 N | 32 | 12 |
Cleansing Solution | Brand Name and Manufacturer | Time per Day | Total Immersion Time |
---|---|---|---|
Sodium bicarbonate-sodium perborate | Protefix Active Cleanser, Queisser Pharma | 15 min | 540 min (6 months) |
Sodium laureth sulfate | Aktident Cleansing Gel, Helago Pharma | 2 min | 360 min (6 months) |
Sodium bicarbonate | Aktident Cleansing Tablet, Helago Pharma | 15 min | 540 min (6 months) |
Tap water | 8 h | 1440 min (6 months) |
Source | Type III Sum of Squares | Df | Mean Square | F | Sig. |
---|---|---|---|---|---|
Corrected model | 0.623 | 11 | 0.057 | 3.637 | 0.001 |
Intercept | 1.072 | 1 | 1.072 | 68.849 | 0.000 |
Attachment | 0.003 | 2 | 0.002 | 0.109 | 0.897 |
Cleansing agent | 0.155 | 3 | 0.052 | 3.313 | 0.026 |
Attachment x Agent | 0.482 | 6 | 0.080 | 5.160 | 0.000 1 |
Error | 0.918 | 59 | 0.016 | ||
Total | 2.684 | 71 | |||
Corrected total | 1.541 | 70 |
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations. |
© 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Share and Cite
Deste Gokay, G.; Ozkir, S.E.; Wolf, T.G.; Gokcimen, G.; Rona, N.; Bicer, M.; Yilmaz, B. The Effect of Denture Cleansing Solutions on the Retention of Precision Attachments: An In Vitro Study. Int. J. Environ. Res. Public Health 2022, 19, 4345. https://doi.org/10.3390/ijerph19074345
Deste Gokay G, Ozkir SE, Wolf TG, Gokcimen G, Rona N, Bicer M, Yilmaz B. The Effect of Denture Cleansing Solutions on the Retention of Precision Attachments: An In Vitro Study. International Journal of Environmental Research and Public Health. 2022; 19(7):4345. https://doi.org/10.3390/ijerph19074345
Chicago/Turabian StyleDeste Gokay, Gonca, Serhat Emre Ozkir, Thomas Gerhard Wolf, Gulsum Gokcimen, Nergiz Rona, Mehmet Bicer, and Burak Yilmaz. 2022. "The Effect of Denture Cleansing Solutions on the Retention of Precision Attachments: An In Vitro Study" International Journal of Environmental Research and Public Health 19, no. 7: 4345. https://doi.org/10.3390/ijerph19074345