Next Article in Journal
Factors Associated with the 30-Day and 1-Year Smoking Abstinence of Women in Korea: The Effect of Nicotine Dependency, Self-Efficacy, and Mental Illness
Previous Article in Journal
Predictors of Changes in Travel Behavior during the COVID-19 Pandemic: The Role of Tourists’ Personalities
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Naturally Occurring Radioactive Materials in Bracelets and Necklaces: Radiological Risk Evaluation

by
Halmat Jalal Hassan
1,2,
Suhairul Hashim
1,3,*,
Noor Zati Hani Abu Hanifah
1,
Sib Krishna Ghoshal
1,
Mohamad Syazwan Mohd Sanusi
1,
Fariza Hanim Binti Suhailin
1,
Muhammad Fahmi Rizal Abdul Hadi
4,
Rozman Mohd Tahar
5 and
David Andrew Bradley
6,7
1
Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, Skudai 81310, Johor, Malaysia
2
Department of Physics, College of Education, University of Sulaimani, Sulaimani 46001, Kurdistan, Iraq
3
Ibnu Sina Institute for Scientific and Industrial Research (ISISIR), Universiti Teknologi Malaysia, Skudai 81310, Johor, Malaysia
4
School of Physics, Universiti Sains Malaysia, Gelugor 11800, Pulau Pinang, Malaysia
5
Atomic Energy Licensing Board, Jalan Dengkil, Batu 24, Dengkil 43000, Selangor, Malaysia
6
Centre for Applied Physics and Radiation Technologies, School of Engineering and Technology, Sunway University, Bandar Sunway 47500, Selangor, Malaysia
7
Department of Physics, University of Surrey, Guilford GU2 7XH, UK
*
Author to whom correspondence should be addressed.
Int. J. Environ. Res. Public Health 2021, 18(21), 11170; https://doi.org/10.3390/ijerph182111170
Submission received: 20 August 2021 / Revised: 14 October 2021 / Accepted: 21 October 2021 / Published: 24 October 2021

Abstract

:
A particular category of jewelry is one involving bracelets and necklaces that are deliberately made to contain naturally occurring radioactive material (NORM)—purveyors making unsubstantiated claims for health benefits from the release of negative ions. Conversely, within the bounds of the linear no-threshold model, long-term use presents a radiological risk to wearers. Evaluation is conducted herein of the radiological risk arising from wearing these products and gamma-ray spectrometry is used to determine the radioactivity levels and annual effective dose of 15 commercially available bracelets (samples B1 to B15) and five necklaces (samples N16 to N20). Various use scenarios are considered; a Geant4 Monte Carlo (Geant4 MC) simulation is also performed to validate the experimental results. The dose conversion coefficient for external radiation and skin equivalent doses were also evaluated. Among the necklaces, sample N16 showed the greatest levels of radioactivity, at 246 ± 35, 1682 ± 118, and 221 ± 40 Bq, for 238U, 232Th, and 40K, respectively. For the bracelets, for 238U and 232Th, sample B15 displayed the greatest level of radioactivity, at 146 ± 21 and 980 ± 71 Bq, respectively. N16 offered the greatest percentage concentrations of U and Th, with means of 0.073 ± 0.0002% and 1.51 ± 0.0015%, respectively, giving rise to an estimated annual effective dose exposure of 1.22 mSv, substantially in excess of the ICRP recommended limit of 1 mSv/year.

1. Introduction

Ionizing radiation sources that exist naturally in the environment are dominated by the primordial terrestrial radionuclides 232Th and 238U, their progeny (forming the so-called decay series) and 40K. To be recognized is that in varying activity concentrations, these exist in all raw materials [1], sometimes being referred to as naturally occurring radioactive material (NORM). In association with extractive-, associated benefications-, and energy production industries, the activity levels of 232Th and 238U in naturally existing raw materials may be anthropogenically enhanced, in many circumstances typically appearing within the processing and utilization residues. In accord with the linear no-threshold model, doses exceeding local natural radiation background levels are linked with an increased radiological risk, a matter raising public health concerns [2,3]. Those same residues are sometimes being seen to be recycled, various external radiation sources, including naturally occurring radionuclides being deliberately included in consumer products, offered for various reasons, including not only matters of practical utility but also claimed increase in well-being [4]. Indeed, radioactive materials have for many years been incorporated in a range of consumer products, those proffered on the basis of a suggested enhancement of well-being forming the main focus of this work, particularly in regard to safety concerns [5]. Chronic exposure from frequent use of these radioactive consumer products (RCP) is both viewed to increase radiation risk to the public as well as potentially impact the environment as a result of discards [6]. Although the number of consumer products containing radioactive substances is currently relatively few in type, their production is seen to be ever-increasing [2].
Regarding RCP and the exemption dose limit for members of the public, in many countries, guidelines have been established, pointing to a need to satisfy the criteria of justification, optimization, and limitation, also authorization, not least in respect of NORM added consumer products [7]. The intent has typically been to introduce measures to avoid exposures exceeding the annual dose limit 1 mSv/year as recommended by the International Commission for Radiation Protection (ICRP) [8], a particular instance being the Malaysian Atomic Energy Licensing Board (AELB) technical document LEM/TEK/69 that specifically addresses consumer products containing sources of radioactivity [9]. Despite such measures, globally harmonized regulations have yet to be established in controlling the radioactive content of consumer products [10], many types of RCP being available for use in daily life, with products posing radiation risk from both external and internal exposure. Reports that exposure to natural radiation leads to beneficial health effects remains a contentious issue among researchers [11]. Here, one calls attention to products that purveyors are calling ionic bracelets and necklaces, items typically containing monazite and zircon at enhanced levels of radioactivity. The suggestion is that through the regular wearing of these items the associated chronic receipt of low dose-rate radiation gives rise to health benefits [12]. The manufacturers refer to this as negative ion technology [13]. Such claimed benefits include: improved circulation, stamina, and flexibility, the ability to detoxify and enhance energy levels, and a link to the prevention of cancer. In addition, such products claimed to contain germanium, have been suggested to produce far-infrared radiation (FIR). This they seek to link with studies that point to FIR therapy offering potential in aiding skin blood flow and in the reduction of heart diseases [14].
The radioactivity of mineral concentrates can be significantly influenced by small amounts of other minerals, such as monazite, containing elevated concentrations of 232Th and its progeny [15]. Monazite can contain up to 27% of U and Th oxides while zircon can contain U and Th oxides in concentrations up to 20% [16]. The IAEA technical document No. 1660 presents the range of typical activity concentrations of 232Th in monazite, at 40–600 Bq/g [17]. From this, it observed that existing minerals such as monazite and zircon added to consumer products could enhance the otherwise very low activity concentration of radionuclides in such items.
Based on the linear no-threshold model and stemming from the associated recommendations of the ICRP, no safe level is offered [18]. Accordingly, in regard to RCP utilization, at a minimum, it is necessary to evaluate the external radiation exposure to members of the public. In what is to follow, Geant4 Monte Carlo (Geant4 MC) simulation, the primary method for assessing the absorbed doses from external radiation, was used to obtain the dose rate conversion coefficient (mSv/h per Bq). The dose rate conversion coefficient was computed with respect to male and female reference phantoms. The results are expressed in terms of equivalent organ dose and external dose rate measurements. The individual annual effective dose from radiation exposure was estimated based on the duration of exposure.

2. Materials and Methods

2.1. Measurement of Activity of 238U, 232Th, and 40K in the Particular Bracelets and Necklaces

A total of 15 bracelets and five necklaces were purchased online, noting manufacturer claims that the products generate negative ions, devoid of supporting scientific detail. Upon delivery, no evidence was found of information as to the radioactivity contained within. For analysis, these bracelets and necklaces were coded as B01-B15 and N16-N20, respectively (Figure 1). The activity of the individual radionuclides 238U, 232Th, and 40K contained within the samples were measured via gamma-ray spectrometry (using an ORTEC GEM Series P-type coaxial HPGe spectrometer, GEM20-76-LB-C-SMPCFG-SV-LB-76). The facility offers 33% relative efficiency and 1.8 keV full-width at half maximum (FWHM) at 1332 keV, providing spectroscopy within the photon energy range 40 keV to several MeV. Each sample was counted for a period of 24 h to ensure highly reliable counting statistics, and the measurement process was replicated twice for each sample. Gamma Vision 8.1 software was used for spectrum acquisition and analysis. Calibrations were made using a 152Eu standard point source, providing photon energies of 121.78, 244.6, 344.3, 411.1, 778.9, 867, 964, 1112, and 1528 keV. The activity of 238U was estimated from the primary sources 214Pb (295, 351) keV, and 214Bi (609, 1764) keV, as these line energies have a high probability emission of gamma [19]. Regarding 226Ra, the line energy 186 keV has not recorded significant difference activity from its daughters (214Pb and 214Bi) due to the secular equilibrium. Concerning the activity of 232Th, comprising 228Ra estimated from both gamma lines of 228Ac (338, 911) keV, 228Th estimated from the resulting gamma lines of 212Pb (238 keV) and 212Bi (727 keV); 208Tl (583, 2614) keV, with 232Th estimated from the average of 228Ra and 228Th.

2.2. Identification of Radioactive Materials Added in the Particular Bracelets and Necklaces

For analysis of elements contained in the purchased products, use was made of a Cartesian geometry energy dispersive X-ray fluorescence (ED-XRF) spectrometer (model; NEX CG–CG1240) [20,21,22]. High atomic number elements (Cs to U) are typically measured using L-line emissions, while lower atomic numbers element composition are generally analyzed using the Kα characteristic lines [23]. The system, with analytical software (RPF-SQX) featuring Rigaku Profile Fitting (RPF) technology, allows semi-quantitative analysis of most sample types without recourse to standards [13,24]. The samples were homogenized in powder form. ED-XRF analysis of seven such bracelets and necklaces was carried out for a duration of 12 min per sample (Table 1).

2.3. Estimation of the Annual Effective Dose from the Use of the Particular Bracelets and Necklaces

Clearly, several factors affect external radiation dose: source activity, shielding, distance, and period of use. To estimate the annual effective dose (AED) from the use of the bracelets and necklaces, simulation was conducted using the Geant4 Monte Carlo (Geant4 MC) radiation transport code version 10.06 patch 3, Physics list: Geant4 electromagnetic (EM) physics (G4EmStandardPhysics_option4), also involving the use of the Medical Internal Radiation Dose Pamphlet 5 (MIRD5) mathematical male and female adult phantoms, the male version being shown as an example in Figure 2 [25,26,27]. Direct gamma radiation from external exposures from 232Th and 238U series nuclides was simulated, also for the single emission of 40K (1460 keV). In consideration of radon dose, as has been noted, bracelets and necklaces are typically considered to be worn only during the day (the time periods over which gamma doses have been evaluated). During such periods of time, the wearer would not be anticipated to remain within a single room of small dimension and low ventilation. In such circumstances, any contributions to radon build from the bracelets would be considered negligible compared to ambient levels.
The bracelets were simulated at the position of the wrist while the necklaces were simulated at the position of the neck, conducted for both male and female phantoms [28].
Dose evaluations were carried out with the bracelets and necklaces located at a 1 mm distance from the covered skin surface. The annual effective dose for external exposure ( E e x t ) can be expressed as [12]:
E e x t   ( m S v / y ) = C n   × D e x t × E t
where E e x t   ( m S v / y ) is the annual effective dose for external exposure, C n     is the activity of nuclide n (Bq), D e x t is the external dose rate conversion factor (mSv/h per Bq) and E t is the annual exposure time (number of hours per year) as indicated in Table 2.
The skin equivalent dose rate H s k i n   ( μ S v / h ) due to use of the bracelets and necklaces was calculated using [2]:
H s k i n ( μ S v / h ) = n D C F s k i n × C n × W T
where   D C F s k i n is the skin dose conversion factor ( μ S v / h   p e r   B q ) , at a distance of 1 mm, C n is the activity of nuclide n (Bq) and W T denotes the tissue weighting factor, with a value 0.01 for skin from ICRP-103; only gamma radiations were simulated, accordingly with a radiation weighting factor of unity (1) (Table 3).
The recorded equivalent dose rates (in mSv/h) and radionuclides identified in the bracelets and necklaces are summarized in Table 4. The annual effective dose (AED) from the bracelets and necklaces was also evaluated based on the use of a calibrated portable detector (Identifinder 2, FLIR), obtained via [6]:
A E D   ( m S v / y ) = E q u i v a l e n t   d o s e   r a t e   ( m S v / h ) × a n n u a l   u s a g e   t i m e   ( h / y )

3. Results and Discussion

In regard to the total activity within each of the bracelets and necklaces, Table 5 shows the results between sample values to be highly variable. For the bracelets (B01–B15), the greatest activity was found to be that in sample B15, at 146 ± 21 and 980 ± 71 Bq for 238U and 232Th, respectively. In contrast, sample B01 recorded very much lower activity, at respective values of 3.16 ± 0.7 and 3.5 ± 0.3 Bq. The range for 40K was between 10.5 ± 2 to 297 ± 55 Bq. In regard to the necklace samples (N16–N20), N16 (a rubber-based necklace) showed the greatest activity at 246 ± 35, 1682 ± 118, and 221 ± 40 Bq, for 238U, 232Th, and 40K, respectively. The gemstone necklace sample N17 recorded the next highest activity at 172 ± 24 and 1075 ± 89 Bq, for 238U and 232Th, respectively.
Figure 3 shows a boxplot analysis of the activity concentration (Bq/g) of 238U, 232Th, and 40K in such bracelet and necklace samples, representing an overall distribution, incorporating data from Joseph et al. [12], Jang et al. [29], and Lee et al. [27], in addition to values from the current study. For the bracelet category, the lower-, median-, and upper-whisker are 0.09, 0.68, and 4.8 Bq/g for 238U, 0.04, 8, and 38 Bq/g for 232Th, and 0.42, 6.4, and 14.1 Bq/g for 40K, respectively. In respect of the necklace category, the results are 0.01, 1.3, and 4.8 Bq/g for 238U, 0.01, 9.83, and 69 Bq/g for 232Th, and 0.35, 5.7, and 14.1 for 40K, respectively. In some cases, the outliers are substantial, being greatest in respect of 232Th for both categories of jewelry; in the current study, the substantial outliers are due to the samples B15 and N16. For 238U, referring to the IAEA No. GSR Part 3 activity concentration of 10 Bq/g for exemption, current study results remain within that range [30].
Activity concentration of primordial radionuclides in bracelets and necklaces from literature data and present study findings are displayed in Table 6.
Table 1 lists the elemental content values of the bracelets and necklaces, varying significantly between products as expected. The concentrations for U and Th range from 21 ± 2 ppm through to 0.073 ± 0.0002% and from 60 ± 1 ppm through to 1.51 ± 0.0015%, respectively, while the % concentration of Zr was 1.33 ± 0.001. Via conversion (1 ppm is equal to 4.06 Bq/kg for Th and 12.35 Bq/kg for U) [31], the respective activity of U and Th for sample N16 was 218.5 ± 1.2 Bq, and 1487 ± 1.5 Bq, followed by the B15 wristband bracelet, the activity of U and Th being 109 ± 1 Bq and 743 ± 1 Bq, respectively. As displayed in Table 7, the total activity for U and Th, between the HPGe results of Table 5 and ED-XRF results from Table 1, are comparable.
The results reveal the bracelets and necklaces to contain elevated amounts of monazite and zircon, indicated by the content of the rare earths Ce, La, Nd, Sm, and Zr, these pointing to the source of radioactivity.
As apparent, sample N16 recorded a considerably greater level of radioactivity compared to other samples. The literature data for such bracelets and pendants Mubarak et al. [32] record a range of activity of 1-3189 and 1-884 Bq, for Th and U, respectively. Moreover, Furuta [2] in Japan recorded radioactivity in bath rock samples that contain monazite from China, at 1300 and 190 Bq/g for Th and U, respectively [2]. IAEA technical report 419 indicated evidence that zircon from China may contain significant elevations in the concentration of radioactivity, additionally with radionuclides concentration in monazite of up to 450 and 60 Bq/g for Th and U, respectively [15]. In the present study, the results reveal the high activity levels due to monazite and zircon contained in the samples. In regard to such products claiming to contain germanium, Table 1 shows no evidence of this element in the present range of bracelets and necklaces.
Table 2 presents the annual effective dose of ionic bracelets and necklaces for three different exposure durations (2 h, 8 h 7 min, and 16 h/day). The exposures for a period of exercise of 2 h/day, show sample N16 giving the highest annual effective dose at 1.53 × 10−1 mSv/year. The lowest annual effective dose was found to be that for metallic bracelet B01, at 1.36 μSv/year, giving rise to exposures less than the annual dose limit of 1 mSv/year for members of the public [7,30]. For a standard exposure time scenario, suggested to be 8 h 7 min/day [27], necklace N16 gives rise to the greatest annual effective dose of 6.21 × 10−1 mSv/year for adult male and female phantoms, remaining within the exemption limit. For a chronic exposure time scenario of say 16 h/day, pointing to the wearing of the products for the whole day but not including sleeping time, bracelet B15 and necklace N16 give rise to annual doses of 1.20 and 1.22 mSv/year, respectively. Accordingly, exceeding the public dose limit. From literature for necklaces, Joseph et al. [12] recorded 1.11 mSv/year for adults, while Jang et al. [29] estimated annual doses for bracelets and necklaces of 0.87 and 0.687 mSv/year respectively for an adult. Present MC simulation results have been compared with the work of Lee et al. [27], using the ICRP reference phantom and MCNPX.
Table 3 shows the dose rate and annual skin equivalent dose from wearing the present bracelets and necklaces, obtained using skin dose conversion coefficient. The highest skin equivalent dose rate H s k i n   ( μ S v / h ) has been observed for necklace N16, at 4.18 × 10−1 μSv/h, at a distance of 1 mm between the source and the covered surface skin. At a wearing time of 16 h per day, the highest annual skin equivalent dose was found to be for N16, at 2.44 mSv/year, while sample B15 recorded the next greatest value at 2.42 mSv/year. Overall the annual skin equivalent dose is less than the public limit of 50 mSv/year for skin [18] due to the small area of exposed skin.
Table 4 displays the dose rates and annual effective dose from bracelet and necklace products obtained using a calibrated IdentiFinder 2 portable detector (FLIR Survey Meter), recording equivalent dose rates in µSv/h and identifying the radionuclides contained within the bracelets and necklaces. For samples B15 and N16, these are found to give rise to an annual dose in excess of the dose limit of 1 mSv/year. The highest equivalent dose rate was 0.235 µSv/h for sample N16. The annual dose in use for 16 h/day achieves a value of 1.37 mSv/year for necklace N16, consistent with the Geant4 MC results.
In summary, the annual dose from the use of the bracelets and necklaces studied herein has been evaluated using the Geant4 MC codes, skin equivalent conversion coefficient, and identiFinder 2 survey meter, comparison being made for results for external dose. In regard to exemption from regulatory control, the IAEA safety standard series No. GSR Part 3 addresses the effective dose incurred by any individual in respect of an exempt practice or exempt source, at 10 μSv/year or less per product [7]. The European Commission 147 guidelines similarly proposes an effective dose for users of consumer products arising from normal use, again not exceeding 10 μSv/year per product [7,33]. Also noted is that the use of radioactive materials in consumer products has been regulated by the European Union [34], not allowing radioactive materials to be added to personal jewelery. Based on the European Commission guidelines, with the exception of sample B01, all of the bracelets and necklaces herein exceed the 10 μSv/year exemption limit. In respect of the ICRP guidance limit of 1 mSv/year annual dose for members of the public, several samples herein exceed that limit in their use of 16 h/day and more. As reported in ICRP-103, unjustified exposures can be applied to a range of consumer products NORM-added. If the benefits of using a consumer product NORM-added cannot be shown to exceed the risk, then a ban would seem to be required [2,34], as would certainly seem to be the case for the presently investigated products. A strong recommendation is made to prohibit radioactive consumer products that exceed the exemption limit.

4. Conclusions

This paper reports on the radioactivity in so-called ionic bracelets and necklaces, measured using an HPGe detector. The activity values were then used to simulate doses in male and female phantoms, computing the dose conversion coefficient, and then performing external radiation dose assessment. Various use scenarios were adopted in evaluating the annual dose. Samples B15 and N16 recorded the greatest level of radioactivity, 238U, 232Th, and 40K being is to be greatest in sample N16. Effective dose evaluation and skin equivalent conversion coefficient results were obtained for external exposure using the MIRD5 phantom. It has been concluded that close contact and chronic use of these consumer products can infer annual effective doses of up to 1.22 mSv/year, exceeding the dose constraint of 1 mSv/year for members of the public. While an absence of any justification for using these bracelets and necklaces is apparent, the online purchase of these products is still available in some countries, including Malaysia. Due to the elevated levels of radioactivity found in these products and insufficient available data on any health benefit, recommendation is made to ban such products from import and sale.

Author Contributions

Conceptualization, methodology, investigation, formal analysis, writing—original draft., H.J.H.; supervision, funding, conceptualization, investigation, writing—original draft, formal analysis., S.H.; conceptualization, investigation N.Z.H.A.H.; investigation., M.S.M.S.; conceptualization M.F.R.A.H.; writing—review and editing, D.A.B., S.K.G. and F.H.B.S.; funding conceptualization R.M.T. All authors have read and agreed to the published version of the manuscript.

Funding

This work was supported by the Ministry of Science, Technology and Innovation (MOSTI) of Malaysia through Kumpulan Wang Amanah (KWA) Majlis Sains dan Penyelidikan Kebangsaan (MSPK) (R.J130000.7317.4B658 and R.J130000.7317.4B659). The authors gratefully acknowledge the Ministry of Higher Education Malaysia and Universiti Teknologi Malaysia through Industry-International Incentive Grant (No. 03M18). We acknowledge the cooperation with the project partners, i.e., International Atomic Energy Agency and Atomic Energy Licensing Board, Malaysia, for expert mission and procurement support through the IAEA TC programme (MAL9018: Strengthening the Regulatory Infrastructure for Radiation and Nuclear Safety).

Institutional Review Board Statement

Not applicable.

Informed Consent Statement

Not applicable.

Conflicts of Interest

There are no conflict of interest to declare.

References

  1. Ahmad, N.; Jaafar, M.S.; Bakhash, M.; Rahim, M. An overview on measurements of natural radioactivity in Malaysia. J. Radiat. Res. Appl. Sci. 2015, 8, 136–141. [Google Scholar] [CrossRef] [Green Version]
  2. Furuta, E. NORM as consumer products: Issue of their being. Radiat. Prot. Dosim. 2011, 146, 178–182. [Google Scholar] [CrossRef]
  3. Furuta, E.; Minowa, H.; Nakahara, H.; Iwaoka, K.; Yonehara, H. Classification of ores used for the radiation source in NORM as consumer products by PGAA. Proc. Radiochem. 2011, 1, 219–225. [Google Scholar] [CrossRef]
  4. ICRP. Dose coefficients for external exposures to environmental sources. ICRP Publ. 144. Ann. ICRP 2020, 49, 11–145. [Google Scholar]
  5. Hassan, H.J.; Hashim, S.; Hanifah, N.Z.A.; Hadi, M.F.; Sanusi, M.S.; Bradley, D.A.; Tenorio, R.G.; Tahar, R.M. The Enhanced Naturally Occurring Radioactivity of Negative Ion Clothing and Attendant Risk. Appl. Sci. 2021, 11, 5412. [Google Scholar] [CrossRef]
  6. Yoo, D.H.; Park, H.-J.; Min, C.H. Evaluation of the annual effective dose due to the external irradiation induced by using NORM added consumer products. Appl. Radiat. Isot. 2019, 154, 108860. [Google Scholar] [CrossRef]
  7. IAEA. Radiation Safety for Consumer Products; International Atomic Energy Agency: Vienna, Austria, 2016. [Google Scholar]
  8. Abu Hanifah, N.Z.H.; Hashim, S.; Hassan, H.J.; Yusof, N.N.; Bradley, D.A. Radioactive material in cosmetic and healthcare products: Regulatory controls. Radiat. Phys. Chem. 2021, 188, 109673. [Google Scholar] [CrossRef]
  9. AELB. Assessment and licensing of consumer product containing radioactive material. In LEM/TEK/69 Sem.1, A; Atomic Energy Licensing Board: Dengkil, Malaysia, 2016. Available online: http://www.aelb.gov.my/malay/dokumen/panduan/lem-tek/LEM%20TEK%2069%20Sem.1.pdf (accessed on 28 July 2021).
  10. Yoo, D.H.; Shin, W.-G.; Lee, H.C.; Choi, H.J.; Testa, M.; Lee, J.K.; Yeom, Y.S.; Kim, C.H.; Min, C.H. An effective dose assessment technique with NORM added consumer products using skin-point source on computational human phantom. Appl. Radiat. Isot. 2016, 118, 56–61. [Google Scholar]
  11. Furuta, E.; Nakahara, H. Dose estimation of radiation exposure from hormesis cosmetics. Jpn. J. Health Phys. 2008, 43, 341–348. [Google Scholar] [CrossRef]
  12. Joseph, S.R.; Kim, J. Radiological Dose Assessment to Members of the Public Using Consumer Products Containing Naturally Occurring Radioactive Materials in Korea. Int. J. Environ. Res. Public Health 2021, 18, 7337. [Google Scholar] [CrossRef]
  13. Pabroa, P.C.B.; Racho, J.M.D.; Bautista, A.T.; Sucgang, R.J.; Castaneda, S.S. X-ray Fluorescence in Member States: Philippines Secrets of Scalar Energy Infused Products as Revealed by XRF Spectrometry; International Atomic Energy Agency (IAEA): Vienna, Austria, 2011; pp. 30–31. [Google Scholar]
  14. Lin, C.-C.; Yang, W.-C.; Chen, M.-C.; Liu, W.-S.; Yang, C.-Y.; Lee, P.-C. Effect of Far Infrared Therapy on Arteriovenous Fistula Maturation: An Open-Label Randomized Controlled Trial. Am. J. Kidney Dis. 2013, 62, 304–311. [Google Scholar]
  15. IAEA. Extent of Environmental Contamination by Naturally Occurring Radioactive Material (NORM) and Technological Options for Mitigation; International Atomic Energy Agency: Vienna, Austria, 2003. [Google Scholar]
  16. Ojovan, M.I.; Lee, W.E.; Kalmykov, S.N. An Introduction to Nuclear Waste Immobilisation; Elsevier: Amsterdam, The Netherlands, 2019. [Google Scholar]
  17. IAEA. Exposure of the Public from Large Deposits of Mineral Residues; International Atomic Energy Agency: Vienna, Austria, 2011. [Google Scholar]
  18. ICRP. The 2007 Recommendations of the International Commission on Radiological Protection; ICRP Publication 103. Annals of the ICRP; International Commission on Radiological Protection: Ottawa, ON, Canada, 2007; Volume 37, pp. 1–332. [Google Scholar]
  19. Clouvas, A.; Xanthos, S.; Antonopoulos-Domis, M.; Silva, J. Monte Carlo calculation of dose rate conversion factors for external exposure to photon emitters in soil. Health Phys. 2000, 78, 295–302. [Google Scholar] [CrossRef]
  20. Jurado-López, A.; de Castro, L.; Pérez-Morales, R. Application of energy-dispersive X-ray fluorescence to jewellery samples determining gold and silver. Gold Bull. 2006, 39, 16–21. [Google Scholar] [CrossRef] [Green Version]
  21. Perring, L.; Nicolas, M.; Andrey, D.; Rime, C.F.; Richoz-Payot, J.; Dubascoux, S.; Poitevin, E. Development and validation of an ED-XRF method for the fast quantification of mineral elements in dry pet food samples. Food Anal. Methods 2017, 10, 1469–1478. [Google Scholar]
  22. Ngo, T.T.; Thomas, S.; Stokes, D.; Benvenuto, M.A.; Roberts-Kirchhoff, E.S. Analysis of Cosmetic Mineral Eyeshadows and Foundations with a Handheld X-ray Fluorescence Analyzer. In Environmental Chemistry: Undergraduate and Graduate Classroom, Laboratory, and Local Community Learning Experiences; ACS Publications: Washington, DC, USA, 2018; pp. 89–103. [Google Scholar]
  23. Potts, P.J.; Webb, P.C. X-ray fluorescence spectrometry. J. Geochem. Explor. 1992, 44, 251–296. [Google Scholar]
  24. Lindon, J.C.; Tranter, G.E.; Koppenaal, D. Encyclopedia of Spectroscopy and Spectrometry; Academic Press: Cambridge, MA, USA, 2016; p. 2467. [Google Scholar]
  25. Snyder, W.; Ford, M.; Warner, G.; Watson, S. A Tabulation of Dose Equivalent per Microcurie-Day for Source and Target Organs of an Adult for Various Radionuclides: Part I; Oakridge National Laboratory Report ORNL-5000: Oak Ridge, TN, USA, 1974. [Google Scholar]
  26. Olsher, R.H.; Van Riper, K.A. Application of a sitting MIRD phantom for effective dose calculations. Radiat. Prot. Dosim. 2005, 116, 392–395. [Google Scholar] [CrossRef]
  27. Lee, H.C.; Yoo, D.H.; Testa, M.; Shin, W.-G.; Choi, H.J.; Ha, W.-H.; Yoo, J.; Yoon, S.; Min, C.H. Effective dose evaluation of NORM-added consumer products using Monte Carlo simulations and the ICRP computational human phantoms. Appl. Radiat. Isot. 2016, 110, 230–235. [Google Scholar] [CrossRef] [PubMed]
  28. Hassan, H.J.; Hashim, S.; Sanusi, M.S.M.; Jamal, M.H.; Hassan, S.A.; Bradley, D.A.; García-Tenorio, R.; Tahar, R.M. The naturally occurring radioactivity of ‘scalar energy’ pendants and concomitant radiation risk. PLoS ONE 2021, 16, e0250528. [Google Scholar] [CrossRef] [PubMed]
  29. Jang, M.; Chung, K.H.; Lim, J.M.; Ji, Y.Y.; Kim, C.J.; Kang, M.J. Analysis and evaluation for consumer goods containing NORM in Korea. Appl. Radiat. Isot. 2017, 126, 293–295. [Google Scholar]
  30. IAEA. Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards; GSR-Part 3; International Atomic Energy Agency: Vienna, Austria, 2014. [Google Scholar]
  31. IAEA. Guidelines for Radioelement Mapping Using Gamma Ray Spectrometry Data; International Atomic Energy Agency: Vienna, Austria, 2003. [Google Scholar]
  32. Mubarak, F.; Soliman, H.; Khadra, S.A. Radiological Risk Due to Quantum Pendants. Middle-East J. Sci. Res. 2016, 24, 2649–2656. [Google Scholar]
  33. Shaw, J.; Dunderdale, J.; Paynter, R. Guidelines for the Regulatory Control of Consumer Product Containing Radioactive Materials in the European Union; Brussels, Belgium. Eur. Comm. Radiat. Prot. 2007, 1, 14–18. [Google Scholar]
  34. Euratom, B. Council Directive 2013/59 EURATOM of 5 December 2013 Laying Down the Basic Safety Standards for the Protection of the Health of Workers and the General Public against the Dangers Arising from Ionizing Radiation, and Repealing Directives 89/618/Euratom, 90/641/Euratom, 96/29/Euratom, 97/43/Euratom and 2003/122/Euratom; Euratom. Off. J. Eur. Communities 2013. [Google Scholar]
Figure 1. Bracelet and necklace samples.
Figure 1. Bracelet and necklace samples.
Ijerph 18 11170 g001
Figure 2. MIRD male human phantoms for AED bracelet and necklace estimates via Geant4 MC Simulation.
Figure 2. MIRD male human phantoms for AED bracelet and necklace estimates via Geant4 MC Simulation.
Ijerph 18 11170 g002
Figure 3. Overall distribution of activity concentration for 238U, 232Th, and 40K in bracelet and necklace samples.
Figure 3. Overall distribution of activity concentration for 238U, 232Th, and 40K in bracelet and necklace samples.
Ijerph 18 11170 g003
Table 1. Elemental concentrations of the bracelets and necklaces. (Quoted in ppm for the purpose of consistency).
Table 1. Elemental concentrations of the bracelets and necklaces. (Quoted in ppm for the purpose of consistency).
SampleElemental Concentration ± Standard Deviation (ppm)
ZrCeLaNdSmUThKGe
B031940 ± 8435 ± 31NDNDND149 ± 22200 ± 549,400 ± 51ND
B06440 ± 5331 ± 16NDNDND21 ± 260 ± 161,700 ± 38ND
B0913,300 ± 10NDNDNDNDND1110 ± 21580 ± 23ND
B132440 ± 8306 ± 15167 ± 1635 ± 11192 ± 1694 ± 13650 ± 7291 ± 15ND
B154500 ± 3125 ± 740 ± 5ND229 ± 20350 ± 17250 ± 10357 ± 23ND
N166900 ± 13445 ± 32419 ± 24ND480 ± 23729 ± 215,100 ± 15737 ± 28ND
N177850 ± 2554 ± 3ND1310 ± 57981 ± 39272 ± 14320 ± 46560 ± 19ND
ND: Not Detected.
Table 2. Annual effective dose from present bracelets and necklaces for three different exposure times.
Table 2. Annual effective dose from present bracelets and necklaces for three different exposure times.
SampleAnnual Effective Dose (mSv/Year)
Exercise (2 h/Day)Standard (8 h 7 min/Day)Chronic (16 h/Day)
B011.36 × 10−35.51 × 10−31.09 × 10−2
B028.30 × 10−33.36 × 10−26.64 × 10−2
B038.90 × 10−23.61 × 10−17.12 × 10−1
B041.11 × 10−24.5 × 10−28.88 × 10−2
B051.22 × 10−24.95 × 10−29.76 × 10−2
B061.97 × 10−27.99 × 10−21.57 × 10−1
B071.1 × 10−24.46 × 10−28.8 × 10−2
B082.26 × 10−29.17 × 10−21.81 × 10−1
B092.55 × 10−21.03 × 10−12.04 × 10−1
B101.30 × 10−25.27 × 10−21.04 × 10−1
B111.50 × 10−26.08 × 10−21.20 × 10−1
B121.80 × 10−27.31 × 10−21.44 × 10−1
B135.12 × 10−22.08 × 10−14.1 × 10−1
B145.80 × 10−22.35 × 10−14.64 × 10−1
B151.50 × 10−16.09 × 10−11.2
N161.53 × 10−16.21 × 10−11.22
N179.64 × 10−23.91 × 10−17.72 × 10−1
N181.49 × 10−26.05 × 10−21.19 × 10−1
N192.83 × 10−21.15 × 10−12.26 × 10−1
N208.85 × 10−33.59 × 10−27.08 × 10−2
Table 3. Dose rate and annual skin equivalent dose of bracelets and necklaces obtained using the skin dose conversion coefficient.
Table 3. Dose rate and annual skin equivalent dose of bracelets and necklaces obtained using the skin dose conversion coefficient.
SampleDose Rate
( μ S v / h )
Annual Skin Equivalent Dose (mSv/Year)
2 h/day8 h 7 min/Day16 h/Day
B032.21 × 10−11.61 × 10−16.53 × 10−11.29
B064.15 × 10−23.03 × 10−21.23 × 10−12.42 × 10−1
B096.23 × 10−24.55 × 10−21.85 × 10−13.64 × 10−1
B131.30 × 10−19.50 × 10−23.86 × 10−17.60 × 10−1
B154.15 × 10−13.03 × 10−11.232.42
N164.18 × 10−13.05 × 10−11.242.44
N178.48 × 10−26.19 × 10−22.51 × 10−14.95 × 10−1
Table 4. Dose rates and annual effective dose from bracelet and necklace products, obtained using the IdentiFinder 2 portable detector.
Table 4. Dose rates and annual effective dose from bracelet and necklace products, obtained using the IdentiFinder 2 portable detector.
SampleDose Rate (µSv/h)Annual Dose (mSv/Year)
2 h/day8 h 7 min/Day16 h/DayRadionuclides
B150.2130.1550.6311.24Th/U
N160.2350.1720.6961.37Th/U
Table 5. Total activities (in Bq) for 238U, 232Th, and 40K for each of the bracelets and necklaces.
Table 5. Total activities (in Bq) for 238U, 232Th, and 40K for each of the bracelets and necklaces.
SampleDescriptionWeight ± SD (g)Activity ± SD* (Bq)
238U232Th40K
B01Metallic bracelet25.3 ± 0.253.16 ± 0.73.5 ± 0.310.5 ± 2
B02Metallic quantum bracelet35.3 ± 0.33.2 ± 0.623.4 ± 272 ± 13
B03Gemstone bracelet (brown)41.7 ± 0.4106 ± 14428 ± 35297 ± 55
B04Gemstone bracelet (black)20 ± 0.194.9 ± 0.632 ± 4.393 ± 15
B05Gemstone bracelet (pink)18.92 ± 0.185.4 ± 0.441 ± 5.592 ± 13
B06Gemstone bracelet (green)51.6 ± 0.415.8 ± 2.618.3 ± 1.7253 ± 45
B07Multi gemstone bracelet19 ± 0.183.9 ± 0.829 ± 4.383.6 ± 15
B08Rob bracelet (blue)11.49 ± 0.114 ± 2.398 ± 18100 ± 18
B09Rubber bracelet (white)12.96 ± 0.1316 ± 3115 ± 9105 ± 18
B10Rob bracelet (pink)5.59 ± 0.054 ± 146 ± 493 ± 16
B11Rubber bracelet (red)16.83 ± 0.1711 ± 156 ± 394 ± 16
B12Rubber bracelet (white)11.7 ± 0.112 ± 173 ± 3106 ± 16
B13Rubber bracelet (blue)16.27 ± 0.1624 ± 2.3290 ± 21109 ± 19
B14Rubber bracelet (black)11.16 ± 0.153 ± 7319 ± 24113 ± 20
B15Wristband bracelet smart power (dark red)25.21 ± 0.2146 ± 21980 ± 7183 ± 15
N16Rubber necklace (black)24.26 ± 0.2246 ± 351682 ± 118221 ± 40
N17Multi gemstone necklace42.94 ± 0.3172 ± 241075 ± 8995 ± 17
N18Rubber necklace (grey)10.57 ± 0.110 ± 1.6110 ± 7.397 ± 17
N19Quantum necklace (brown)53.62 ± 0.543 ± 3.2281 ± 1484 ± 6.5
N20Gemstone necklace (green)7.05 ± 0.079 ± 0.543 ± 773 ± 13
SD*: Standard deviation.
Table 6. Activity of radionuclides 238U, 232Th, and 40K in bracelets and necklaces. Literature data and data from this study.
Table 6. Activity of radionuclides 238U, 232Th, and 40K in bracelets and necklaces. Literature data and data from this study.
NoSampleActivity Concentration ± SD (Bq/g)References
238U232Th40K
1Bracelet4202[12]
2BraceletNA15.114.1[27]
3Bracelet0.1–2.810.04–11.9NA[29]
4Bracelet0.01 ± 0.01–5.8 ± 0.80.14 ± 0.01–38 ± 30.4 ± 0.1–16.9 ± 3Present study
5Necklace424NA[12]
6NecklaceNA1514[27]
7Necklace0.01–1.60.01 -100.4–2[29]
8Necklace0.8 ± 0.05–10 ± 1.55.4 ± 0.3–69 ± 52 ± 0.4–10.4 ± 1.8Present study
NA: Not Available.
Table 7. Total activity ± SD (in Bq) for U and Th. A comparison between the results of Table 5 (HPGe) and Table 1 (ED-XRF).
Table 7. Total activity ± SD (in Bq) for U and Th. A comparison between the results of Table 5 (HPGe) and Table 1 (ED-XRF).
SampleHPGeED-XRF
UThUTh
B03106 ± 14428 ± 3576.73 ± 1372.5 ± 0.8
B0615.8 ± 2.618.3 ± 1.713.4 ± 1.3 12.5 ± 0.2
B0916 ± 3115 ± 9ND58 ± 0.4
B1324 ± 2.3290 ± 2118.9 ± 0.4241 ± 0.5
B15146 ± 21980 ± 71109 ± 1743 ± 1
N16246 ± 351682 ± 118218.5 ± 1.21487 ± 1.5
N17172 ± 241075 ± 89144 ± 1 754 ± 0.7
Publisher’s Note: MDPI stays neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Share and Cite

MDPI and ACS Style

Hassan, H.J.; Hashim, S.; Abu Hanifah, N.Z.H.; Ghoshal, S.K.; Sanusi, M.S.M.; Binti Suhailin, F.H.; Abdul Hadi, M.F.R.; Tahar, R.M.; Bradley, D.A. Naturally Occurring Radioactive Materials in Bracelets and Necklaces: Radiological Risk Evaluation. Int. J. Environ. Res. Public Health 2021, 18, 11170. https://doi.org/10.3390/ijerph182111170

AMA Style

Hassan HJ, Hashim S, Abu Hanifah NZH, Ghoshal SK, Sanusi MSM, Binti Suhailin FH, Abdul Hadi MFR, Tahar RM, Bradley DA. Naturally Occurring Radioactive Materials in Bracelets and Necklaces: Radiological Risk Evaluation. International Journal of Environmental Research and Public Health. 2021; 18(21):11170. https://doi.org/10.3390/ijerph182111170

Chicago/Turabian Style

Hassan, Halmat Jalal, Suhairul Hashim, Noor Zati Hani Abu Hanifah, Sib Krishna Ghoshal, Mohamad Syazwan Mohd Sanusi, Fariza Hanim Binti Suhailin, Muhammad Fahmi Rizal Abdul Hadi, Rozman Mohd Tahar, and David Andrew Bradley. 2021. "Naturally Occurring Radioactive Materials in Bracelets and Necklaces: Radiological Risk Evaluation" International Journal of Environmental Research and Public Health 18, no. 21: 11170. https://doi.org/10.3390/ijerph182111170

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop