Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = transcartilage neuromonitoring

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 1232 KiB  
Article
Laryngeal Neural Monitoring during Pediatric Thyroid Cancer Surgery—Is Transcartilage Recording a Preferable Method?
by Tzu-Yen Huang, Hoon-Yub Kim, Gianlorenzo Dionigi, I-Cheng Lu, Pi-Ying Chang, Feng-Yu Chiang, Yi-Chu Lin, Hsin-Yi Tseng, Cheng-Hsin Liu and Che-Wei Wu
Cancers 2021, 13(16), 4051; https://doi.org/10.3390/cancers13164051 - 11 Aug 2021
Cited by 12 | Viewed by 2693
Abstract
The use of transcartilage (TC) intraoperative neuromonitoring (IONM) in a pediatric population has not been reported. This study evaluated the feasibility and the benefit of using TC-IONM for thyroid cancer surgery in a pediatric population. This retrospective single-center study enrolled 33 pediatric patients [...] Read more.
The use of transcartilage (TC) intraoperative neuromonitoring (IONM) in a pediatric population has not been reported. This study evaluated the feasibility and the benefit of using TC-IONM for thyroid cancer surgery in a pediatric population. This retrospective single-center study enrolled 33 pediatric patients who had received an IONM-assisted thyroidectomy. Demographic characteristics, standardized IONM laryngeal examinations and stimulation information (L1-V1-R1-R2-V2-L2) were compared between endotracheal tube (ET) and TC methods. In the 15 cancer patients (30 nerves), TC-IONM provided significant higher electromyography (EMG) amplitude (p < 0.001), signal stability (lower V1/V2 signal correlation, r = 0.955 vs. r = 0.484, p = 0.004), signal quality (higher ratio of V1 or V2 amplitude <500 µV, 0.0% vs. 43.8%, p = 0.005) and lower R1-R2p change (7.1% vs. 37.5%, p = 0.049) compared to ET-IONM. In the 18 benign patients (28 nerves), TC-IONM provided significantly higher EMG amplitude (p < 0.001), signal stability (r = 0.945 vs. r = 0.746, p = 0.0324) and non-significant higher signal quality and R1-R2p change. This report is the first to discuss the use of TC-IONM in pediatric thyroid surgery. In contrast with ET-IONM, TC-IONM had superior amplitude, stability and quality of EMG signals, which greatly facilitates the meticulous recurrent laryngeal nerve dissection in pediatric thyroidectomies. The TC-IONM method can be considered a feasible, effective and preferable method of monitored thyroidectomy in pediatric thyroid cancer. Full article
(This article belongs to the Special Issue Innovations in the Integrated Management of Pediatric Thyroid Cancer)
Show Figures

Figure 1

Back to TopTop