Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = star-type grid concrete wall

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
15 pages, 4458 KiB  
Article
Seismic Response of Star-Type Grid Concrete Wall Structure by Numerical Modeling
by Baizan Tang, Yuying Dong, Wen Bai, Hua-Peng Chen, Haiyang Zhuang and Wenchao Deng
Materials 2022, 15(23), 8519; https://doi.org/10.3390/ma15238519 - 29 Nov 2022
Viewed by 1944
Abstract
Cement polystyrene shell mold (CPSM) grid concrete walls have been widely applied in the construction of low and mid-rise buildings with higher load-bearing and insulation properties. A star-type grid concrete wall was constructed based on the infill wall simplified to an equivalent diagonal [...] Read more.
Cement polystyrene shell mold (CPSM) grid concrete walls have been widely applied in the construction of low and mid-rise buildings with higher load-bearing and insulation properties. A star-type grid concrete wall was constructed based on the infill wall simplified to an equivalent diagonal bracing model. To investigate the seismic responses and behavior of a star-type grid concrete wall structure, an overall time-history numerical simulation was carried out in this paper. Typical results, including acceleration, deformation, hysteresis curve and failure pattern of this novel construction system, were interpreted. Results indicate that the star-type grid concrete wall structure has satisfactory seismic performance, including energy dissipation capacity. The structure has higher lateral stiffness and can work in an elastic state under major earthquakes. Accordingly, it is more sensitive to near-fault ground motion with higher frequency components. Meanwhile, the structural inter-story drift angle is less than the limit value of lighter damage when subjected to a super-major earthquake, and the structure presents shear deformation. The openings significantly affect the failure mode, the star-type grid concrete wall with a window (a small aspect ratio less than 1.11) conforms to shear failure, and the wall with a door (aspect ratio of 2.5) conforms to bending-shear failure. The diagonal bracing can distribute the stress in the wall, especially the concrete lattice beam, and effectively resist the lateral forces via the concrete lattice column, improving the ductility and integrity of the structural system. Full article
(This article belongs to the Special Issue Seismic Design and Structures Analysis of Construction Materials)