Article
Using an Electronic Goniometer to Assess the Influence of Single-Application Kinesiology Taping on Unstable Shoulder Proprioception and Function
by Ewa Bręborowicz, Izabela Olczak, Przemysław Lubiatowski, Piotr Ogrodowicz, Marta Ślęzak, Maciej Bręborowicz and Leszek Romanowski
Sensors 2025, 25(7), 2326; https://doi.org/10.3390/s25072326 - 6 Apr 2025
Viewed by 956
Abstract
Background: Glenohumeral joint instability is associated with a proprioception deficit. Joint position sense can be improved through targeted exercises and kinesiology taping (KT). While previous studies have examined the effects of KT on proprioception, most have focused on the knee joint, with limited [...] Read more.
Background: Glenohumeral joint instability is associated with a proprioception deficit. Joint position sense can be improved through targeted exercises and kinesiology taping (KT). While previous studies have examined the effects of KT on proprioception, most have focused on the knee joint, with limited research on unstable shoulder joints. Most studies have used commonly available equipment (e.g., the Biodex system). An electronic goniometer, the “Propriometer”, is a useful tool for assessing proprioception in shoulder joint instability; however, its application in evaluating the effects of KT on shoulder proprioception remains unexplored. This study aimed to (1) assess the usability of the Propriometer for evaluating the effects of KT on unstable shoulders and (2) determine the impact of a single KT application on joint position sense and limb function in individuals with anterior, post-traumatic shoulder joint instability. Methods and Materials: The study included 30 individuals with anterior, unilateral, post-traumatic shoulder joint instability (8 women, 22 men, mean age 26 years). A control group consisted of 35 healthy volunteers (9 women, 26 men, mean age 24 years). Proprioception assessment (active joint position reproduction evaluation) was performed in both groups using the Propriometer, which measures joint position in real time with an accuracy of 0.1° across all axes. The study methodology was validated and used to examine shoulder proprioception. The current study focused on assessing the effects of KT, which had not been previously tested with this device Assessments were conducted before KT application and three days’ post-application. Additionally, patients completed the Western Ontario Shoulder Instability Index (WOSI) self-assessment questionnaire before and three days after the therapy. Results: Results of the mean joint position reproduction error indicate a proprioceptive deficit in patients with shoulder joint instability. However, the analyzed KT application did not show a significant change in the magnitude of the active joint position reproduction error. Conversely, KT therapy significantly improved patients’ subjective assessment of shoulder function and stability as measured by the WOSI. Conclusions: The Propriometer goniometer and testing methodology are effective tools for assessing the impact of KT on proprioception in shoulder instability. While KT application did not significantly influence shoulder proprioception, it did improve patients’ perceived joint stability and function. Full article
Show Figures

Figure 1

15 pages, 1945 KB  
Article
Shoulder Range of Motion Measurement Using Inertial Measurement Unit–Concurrent Validity and Reliability
by Jakub Kaszyński, Cezary Baka, Martyna Białecka and Przemysław Lubiatowski
Sensors 2023, 23(17), 7499; https://doi.org/10.3390/s23177499 - 29 Aug 2023
Cited by 10 | Viewed by 3614
Abstract
This study aimed to evaluate the reliability of the RSQ Motion sensor and its validity against the Propriometer and electronic goniometer in measuring the active range of motion (ROM) of the shoulder. The study included 15 volunteers (mean age 24.73 ± 3.31) without [...] Read more.
This study aimed to evaluate the reliability of the RSQ Motion sensor and its validity against the Propriometer and electronic goniometer in measuring the active range of motion (ROM) of the shoulder. The study included 15 volunteers (mean age 24.73 ± 3.31) without any clinical symptoms with no history of trauma, disease, or surgery to the upper limb. Four movements were tested: flexion, abduction, external and internal rotation. Validation was assessed in the full range of active shoulder motion. Reliability was revised in full active ROM, a fixed angle of 90 degrees for flexion and abduction, and 45 degrees for internal and external rotation. Each participant was assessed three times: on the first day by both testers and on the second day only by one of the testers. Goniometer and RSQ Motion sensors showed moderate to excellent correlation for all tested movements (ICC 0.61–0.97, LOA < 23 degrees). Analysis of inter-rater reliability showed good to excellent agreement between both testers (ICC 0.74–0.97, LOA 13–35 degrees). Analysis of intra-rater reliability showed moderate to a good agreement (ICC 0.7–0.88, LOA 22–37 degrees). The shoulder internal and external rotation measurement with RSQ Motion sensors is valid and reliable. There is a high level of inter-rater and intra-rater reliability for the RSQ Motion sensors and Propriometer. Full article
(This article belongs to the Special Issue IMU Sensors for Human Activity Monitoring)
Show Figures

Figure 1