Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = polyaluminum titanium silicate chloride

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
33 pages, 9024 KiB  
Article
Performance of PATC-PDMDAAC Composite Coagulants in Low-Temperature and Low-Turbidity Water Treatment
by Peng Zhang, Lina Liao and Guocheng Zhu
Materials 2019, 12(17), 2824; https://doi.org/10.3390/ma12172824 - 2 Sep 2019
Cited by 29 | Viewed by 4846
Abstract
A novel composite was synthesized by using flocculant polyaluminum titanium silicate chloride (PATC) and poly(diallyldimethylammonium chloride) (PDMDAAC) monomers to treat low-temperature and low-turbidity water. The structure and physicochemical properties of PATC-PDMDAAC were analyzed by Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis/differential scanning calorimetry [...] Read more.
A novel composite was synthesized by using flocculant polyaluminum titanium silicate chloride (PATC) and poly(diallyldimethylammonium chloride) (PDMDAAC) monomers to treat low-temperature and low-turbidity water. The structure and physicochemical properties of PATC-PDMDAAC were analyzed by Fourier transform infrared spectroscopy (FTIR), thermogravimetric analysis/differential scanning calorimetry (TG/DSC), X-ray diffraction spectroscopy (XRD), and scanning electron microscopy–energy dispersion spectrum (SEM-EDS). The compound flocculant produced new functional groups exhibiting great thermal stability, and the complex chemical reaction between the two monomers generated new substances with reticular structures. Coagulation performance results showed that the PATC-PDMDAAC had an organic and inorganic ratio of 0.15 and exhibited excellent removal efficiency at pH 9.0, dosage of 1.80 mg/L, sedimentation time of 40 min, and a stirring speed of 110 r/min. The optimal treatment efficiency reduced the turbidity to 0.56 NTU (Nephelometric Turbidity Unit). The removal rates of TOC (Total Organic Carbon) and UV254 (Ultraviolet 254) were 62.18% (from 7.23 mg/L to 2.734 mg/L) and 99.99% (from 10 mg/L to 0.001 mg/L). The 3D fluorescence, zeta potential and kinetic analysis in the flocculation process indicated that coagulant electroneutralization and adsorption bridge in a slightly alkaline environment played a dominant role, and a sufficient and effective collision occurred between the coagulant and particulate matter under the optimal dosage. Lastly, PATC-PDMDAAC has more advantage than conventional flocculants in the treatment of low-temperature and low-turbidity water in the Xiangjiang River. Full article
Show Figures

Graphical abstract

19 pages, 6584 KiB  
Article
Preparation and Characterization of Polyaluminum Titanium Silicate and its Performance in the Treatment of Low-Turbidity Water
by Lina Liao and Peng Zhang
Processes 2018, 6(8), 125; https://doi.org/10.3390/pr6080125 - 11 Aug 2018
Cited by 23 | Viewed by 6059
Abstract
Using conventional coagulant, low turbidity water is difficult to achieve standard. This research uses aluminum chloride, titanium tetrachloride, and sodium silicate as raw materials for the preparation of polyaluminum titanium silicate chloride (PATC). PATC is used to treat low turbidity. The synthetic PATC [...] Read more.
Using conventional coagulant, low turbidity water is difficult to achieve standard. This research uses aluminum chloride, titanium tetrachloride, and sodium silicate as raw materials for the preparation of polyaluminum titanium silicate chloride (PATC). PATC is used to treat low turbidity. The synthetic PATC showed the best coagulating effect in treated water under the following experimental conditions: Reaction temperature of 50 °C, and n(Ti)/n(Al), n(-OH)/n(Ti+Al), and n(Si)/n(Ti+Al) were 0.3, 0.2, and 1.0, respectively. The species distribution and the transformation of PATC showed that the interaction between titanium tetrachloride, sodium silicate, and the hydrolysate of Al influenced the morphology distribution of Al. Temperature and -OH greatly affected the distribution of Alb in PATC. The analysis of infrared spectra and X-ray diffraction indicated that both titanium tetrachloride and sodium silicate had complex chemical reactions with aluminum chloride. Si-O-Ti and Si-O-Al produced by the reaction affected the PATC treatment of low-turbidity water. Scanning electron microscopy showed, that compared with polyaluminum chloride(PAC), the PATC cluster was more compact, showed greater pore structure, and presented better flocculation precipitation. The optimal reaction conditions were an initial turbidity of 10 nephelometric turbidity unit(NTU), PATC dosage of 9 mg/L, pH of 8 for the simulated water sample, stirring speed of 50 r/min, and settling time of 50 min, which were determined by Orthogonal experiment. The zeta potential of the reaction process was analyzed. In the treatment of low-turbidity water, PATC mainly functioned by adsorbing, bridging, and sweeping flocculation. Electrical neutralization played an auxiliary role. Full article
(This article belongs to the Special Issue Wastewater Treatment Processes)
Show Figures

Figure 1

Back to TopTop