Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

remove_circle_outline

Article Types

Countries / Regions

remove_circle_outline

Search Results (1)

Search Parameters:
Keywords = luteolin-7-O-β-d-glucuronopyranosyl (1→2)-O-β-d-glucuronopyranoside

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
10 pages, 1450 KB  
Article
Simultaneous Determination of Four Marker Compounds in Lobelia chinensis Lour. Extract by HPLC-PDA
by Beom-Geun Jo, Young-Hun Park, Ki Hyun Kim, Su-Nam Kim and Min Hye Yang
Appl. Sci. 2021, 11(24), 12080; https://doi.org/10.3390/app112412080 - 18 Dec 2021
Cited by 3 | Viewed by 3587
Abstract
Lobelia chinensis Lour. (L. chinensis) has traditionally been used as a treatment for snake bites, high fever, jaundice, edema, and diarrhea, and modern studies have reported its anti-inflammatory, antioxidant, and antiviral activities. L. chinensis contains various compounds, such as flavonoids and [...] Read more.
Lobelia chinensis Lour. (L. chinensis) has traditionally been used as a treatment for snake bites, high fever, jaundice, edema, and diarrhea, and modern studies have reported its anti-inflammatory, antioxidant, and antiviral activities. L. chinensis contains various compounds, such as flavonoids and coumarins, and its flavonoid components have been identified in many studies. In this study, a high-performance liquid chromatograph equipped with a photodiode array (PDA) detector and an Aegispak C18-L reverse-phase column (4.6 mm × 250 mm i.d., 5 μm) was used to simultaneously analyze four marker components in L. chinensis for standardization purposes. HPLC-PDA (detection at 340 nm), performed using a 0.1% formic acid-water/0.1% formic acid-acetonitrile gradient, separated the four marker compounds: luteolin-7-O-β-d-glucuronopyranosyl (1→2)-O-β-d-glucuronopyranoside, clerodendrin, chrysoeriol-7-O-diglucuronide, and diosmin. The developed analytical method showed excellent linearity values (r2 > 0.9991), limits of detection (LODs: 0.376–2.152 μg/mL), limits of quantification (LOQs: 1.147–6.521 μg/mL), intra- and inter-day precisions (RSD < 1.96%), and analyte recoveries (96.83–127.07%; RSD < 1.73%); thus, it was found to be suitable for the simultaneous analysis of these four marker compounds in L. chinensis. Full article
(This article belongs to the Topic Frontiers in Phytochemicals)
Show Figures

Figure 1

Back to TopTop