Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = immunochromatographic (ICG) assay

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
18 pages, 2283 KiB  
Article
Serological Evidence of Human Orthohantavirus Infections in Barbados, 2008 to 2016
by Kirk Osmond Douglas, Thelma Alafia Samuels, Rommel Iheozor-Ejiofor, Olli Vapalahti, Tarja Sironen and Marquita Gittens-St. Hilaire
Pathogens 2021, 10(5), 571; https://doi.org/10.3390/pathogens10050571 - 8 May 2021
Cited by 6 | Viewed by 3552
Abstract
Background: Hantavirus pulmonary syndrome (HPS) is well-known in South and North America; however, not enough data exist for the Caribbean. The first report of clinical orthohantavirus infection was obtained in Barbados, but no other evidence of clinical orthohantavirus infections among adults in the [...] Read more.
Background: Hantavirus pulmonary syndrome (HPS) is well-known in South and North America; however, not enough data exist for the Caribbean. The first report of clinical orthohantavirus infection was obtained in Barbados, but no other evidence of clinical orthohantavirus infections among adults in the Caribbean has been documented. Methods: Using enzyme linked immunosorbent assay (ELISA) tests followed by confirmatory testing with immunofluorescent assays (IFA), immunochromatographic (ICG) tests, and pseudotype focus reduction neutralization tests (pFRNT), we retrospectively and prospectively detected orthohantavirus-specific antibodies among patients with febrile illness in Barbados. Results: The orthohantavirus prevalence rate varied from 5.8 to 102.6 cases per 100,000 persons among febrile patients who sought medical attention annually between 2008 and 2016. Two major orthohantavirus epidemics occurred in Barbados during 2010 and 2016. Peak orthohantavis infections were observed observed during the rainy season (August) and prevalence rates were significantly higher in females than males and in patients from urban parishes than rural parishes. Conclusions: Orthohantavirus infections are still occurring in Barbados and in some patients along with multiple pathogen infections (CHIKV, ZIKV, DENV and Leptospira). Orthohantavirus infections are more prevalent during periods of high rainfall (rainy season) with peak transmission in August; females are more likely to be infected than males and infections are more likely among patients from urban rather than rural parishes in Barbados. Full article
(This article belongs to the Special Issue Epidemiology, Surveillance and Control of Infectious Diseases)
Show Figures

Figure 1

14 pages, 2785 KiB  
Article
Development of a Calibration Strip for Immunochromatographic Assay Detection Systems
by Yue-Ming Gao, Jian-Chong Wei, Peng-Un Mak, Mang-I. Vai, Min Du and Sio-Hang Pun
Sensors 2016, 16(7), 1007; https://doi.org/10.3390/s16071007 - 29 Jun 2016
Cited by 8 | Viewed by 6609
Abstract
With many benefits and applications, immunochromatographic (ICG) assay detection systems have been reported on a great deal. However, the existing research mainly focuses on increasing the dynamic detection range or application fields. Calibration of the detection system, which has a great influence on [...] Read more.
With many benefits and applications, immunochromatographic (ICG) assay detection systems have been reported on a great deal. However, the existing research mainly focuses on increasing the dynamic detection range or application fields. Calibration of the detection system, which has a great influence on the detection accuracy, has not been addressed properly. In this context, this work develops a calibration strip for ICG assay photoelectric detection systems. An image of the test strip is captured by an image acquisition device, followed by performing a fuzzy c-means (FCM) clustering algorithm and maximin-distance algorithm for image segmentation. Additionally, experiments are conducted to find the best characteristic quantity. By analyzing the linear coefficient, an average value of hue (H) at 14 min is chosen as the characteristic quantity and the empirical formula between H and optical density (OD) value is established. Therefore, H, saturation (S), and value (V) are calculated by a number of selected OD values. Then, H, S, and V values are transferred to the RGB color space and a high-resolution printer is used to print the strip images on cellulose nitrate membranes. Finally, verification of the printed calibration strips is conducted by analyzing the linear correlation between OD and the spectral reflectance, which shows a good linear correlation (R2 = 98.78%). Full article
(This article belongs to the Special Issue Point-of-Care Biosensors)
Show Figures

Figure 1

Back to TopTop