Export citation of selected articles as:
16 pages, 9639 KB  
Article
Hierarchical Hypervapotron Structure Integrated with Microchannels for Advancement of Thermohydraulic Performance
by Xin Meng, Kai Cheng, Qi Zhao and Xuemei Chen
Symmetry 2024, 16(8), 1089; https://doi.org/10.3390/sym16081089 - 22 Aug 2024
Cited by 2 | Viewed by 2524
Abstract
The hypervapotron structure was considered to be a feasible configuration to meet the high heat-dissipating requirement of divertors in nuclear fusion devices. In this work, symmetric CuCrZr-based transverse microchannels (TMHC) and longitudinal microchannels (LMHC) with an integrated hypervapotron channel were proposed and manufactured, [...] Read more.
The hypervapotron structure was considered to be a feasible configuration to meet the high heat-dissipating requirement of divertors in nuclear fusion devices. In this work, symmetric CuCrZr-based transverse microchannels (TMHC) and longitudinal microchannels (LMHC) with an integrated hypervapotron channel were proposed and manufactured, and subcooled flow boiling experiments were conducted using deionized water at an inlet temperature of 20 °C with a traditional flat-type hypervapotron channel (FHC) for comparison. The LMHC and TMHC obtained lower wall temperatures than the FHC for all conditions, and the TMHC yielded the lowest temperatures. The heat transfer coefficients of the LMHC and TMHC outperformed the FHC due to the enlarged heat transfer area, and the TMHC had the greatest heat transfer coefficient (maximumly increased by 132% compared to the FHC) because the transverse-arranged microchannels were conductive, promoting the convection and liquid replenishment ability by introducing branch flow between fins; however, the microchannels of the LMHC were insensible to flow velocities due to the block effect of longitudinal microchannels. The LMHC obtained the largest pressure drop, and the pressure drop for the FHC and TMHC were comparable since the transverse-placed microchannels had little effect on frictional pressure loss. The TMHC attained the greatest comprehensive thermohydraulic performance which might bring significant insight to the structural design of hypervapotron devices. Full article
(This article belongs to the Special Issue Feature Papers in Section "Engineering and Materials" 2024)
Show Figures

Figure 1

17 pages, 5171 KB  
Article
Pressure Drop Characteristics of Subcooled Water in a Hypervapotron under High and Non-Uniform Heat Fluxes
by Ge Zhu, Ge Mei, Jianguo Yan and Shujian Tian
Energies 2023, 16(24), 8121; https://doi.org/10.3390/en16248121 - 18 Dec 2023
Cited by 1 | Viewed by 1937
Abstract
To study the pressure drop characteristics of hypervapotron, which was designed as a water-cooling structure in the divertor dome of the fusion reactor, the pressure drop tests of subcooled water were carried out in a vertically upward hypervapotron. To simulate the one-side radiant [...] Read more.
To study the pressure drop characteristics of hypervapotron, which was designed as a water-cooling structure in the divertor dome of the fusion reactor, the pressure drop tests of subcooled water were carried out in a vertically upward hypervapotron. To simulate the one-side radiant heating condition in the engineering application, the non-uniform heat fluxes were obtained by using the off-center electrically heating method. The system parameters were as follows: mass flux G = 2000–5000 kg·m−2·s−1, inlet pressure p = 2–4 MPa, and equivalent one-side radiating heat flux qe = 0–5 MW·m−2. The effects of the parameters on the pressure drop were discussed in detail. It was observed that in the single-phase (SP) region, the pressure drop was little influenced by the inlet fluid temperature (Tb,in). However, in the subcooled boiling region, the pressure drop increased rapidly with the increasing Tb,in. A higher G leads to a high pressure drop. In the SP region, the influence of p on the pressure drop is not obvious, and the pressure drop decreased with the increasing qe. The test data are used to evaluate the typical pressure drop correlation, and the results show that none of these correlations can predict the pressure drop well under the test conditions. Therefore, a new pressure drop correlation is proposed for subcooled water in a hypervapotron under high and non-uniform heat fluxes. The new correlation has a high prediction accuracy for the test data, and the mean relative error (MRE) and root mean square error (RMSE) are 0.72% and 4.33%, respectively. The test results have a reference value for the design of the water-cooling structure of the diverter. Full article