Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (2)

Search Parameters:
Keywords = hybrid PV/FC/BS

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
20 pages, 4991 KiB  
Article
Design and Sensitivity Analysis of Hybrid Photovoltaic-Fuel-Cell-Battery System to Supply a Small Community at Saudi NEOM City
by Hegazy Rezk, N. Kanagaraj and Mujahed Al-Dhaifallah
Sustainability 2020, 12(8), 3341; https://doi.org/10.3390/su12083341 - 20 Apr 2020
Cited by 40 | Viewed by 6028
Abstract
This research paper aimed to design and present a sensitivity analysis of a hybrid photovoltaic-fuel-cell-battery (PV/FC/B) system to supply a small community for the recently planned grand city NEOM in Saudi Arabia. The location of the city of NEOM is characterized by a [...] Read more.
This research paper aimed to design and present a sensitivity analysis of a hybrid photovoltaic-fuel-cell-battery (PV/FC/B) system to supply a small community for the recently planned grand city NEOM in Saudi Arabia. The location of the city of NEOM is characterized by a high average level of solar irradiance. The average daily horizontal solar radiation is around 5.85 kWh/m2. A detailed feasibility and techno-economic evaluation of a PV/FC/B hybrid energy system were done to supply a daily load demand of 500 kWh (peak-35 kW). The PV array was the main source to meet the load demand. During the surplus periods, the battery was charged using extra energy and powered the electrolyzer for hydrogen production. The produced hydrogen was stored for later use. During the deficit periods, the FC and/or battery supported the PV array to meet the load demand. Two benchmarks, the cost of energy (COE) and net present cost (NPC), were used to identify the best size of the PV/FC/B system. Variation of the tilt angle of the PV array and the derating factor were considered to determine the effect of the performance of the PV/FC/B system’s COE and NPC. The main findings confirmed that a 200 kW PV array, 40 kW FC, 96 batteries, 50 kW converter, 110 kW electrolyzer, and 50 kg hydrogen tank was the best option to supply the load demand. The values of total NPC and COE were $500,823 and $0.126/kWh. The annual excess energy was very sensitive to the declination angle of the PV array. The minimum annual excess energy was achieved at an angle of 30 degrees. It decreased by 75.7% and by 60.6% compared to a horizontal surface and 50 degrees of declination, respectively. To prove the viability of the proposed system, a comparison with grid extension along with a diesel generation system was carried out. Full article
Show Figures

Figure 1

19 pages, 6504 KiB  
Article
An Optimal Sizing of Stand-Alone Hybrid PV-Fuel Cell-Battery to Desalinate Seawater at Saudi NEOM City
by Hegazy Rezk, Mohammed Alghassab and Hamdy A. Ziedan
Processes 2020, 8(4), 382; https://doi.org/10.3390/pr8040382 - 25 Mar 2020
Cited by 70 | Viewed by 8015
Abstract
NEOM City in Saudi Arabia is planned to be the first environmentally friendly city in the world that is powered by renewable energy sources minimizing CO2 emissions to reduce the effect of global warming according to Saudi Arabia’s Vision 2030. In recent [...] Read more.
NEOM City in Saudi Arabia is planned to be the first environmentally friendly city in the world that is powered by renewable energy sources minimizing CO2 emissions to reduce the effect of global warming according to Saudi Arabia’s Vision 2030. In recent years, Saudi Arabia has had a problem with water scarcity. The main factors affecting water security are unequal water distribution, wrong use of water resources and using bad or less efficient irrigation techniques. This paper is aimed to provide a detailed feasibility and techno-economic evaluation of using several scenarios of a stand-alone hybrid renewable energy system to satisfy the electrical energy needs for an environmentally friendly seawater desalination plant which feeds 150 m−3 day−1 of freshwater to 1000 people in NEOM City, Saudi Arabia. The first scenario is based on hybrid solar photovoltaic PV, fuel cells (FC) with a hydrogen storage system and batteries system (BS), while the second and third scenarios are based on hybrid PV/BS and PV/FC with a hydrogen storage system, respectively. HOMER® software was used to obtain the optimal configuration based on techno-economic analysis of each component of the hybrid renewable energy systems and an economic and environmental point of view based on the values of net present cost (NPC) and cost of energy (COE). Based on the obtained results, the best configuration is PV/FC/BS. The optimal size and related costs for the optimal size are 235 kW PV array, 30 kW FC, 144 batteries, 30 kW converter, 130 kW electrolyzer, and 25 kg hydrogen tank is considered the best option for powering a 150 m3 reverse osmosis (RO) desalination plant. The values of net present cost (NPC) and the cost of energy (COE) are $438,657 and $0.117/kWh, respectively. From the authors’ point view, the proposed system is one among the foremost environmentally friendly systems to provide electric energy to the seawater desalination plant, especially when connecting to the utility grid, because it is ready to reduce a large amount of greenhouse gas emissions due to using oil/nature gas in utility generation stations to reduce the effect of global warming. Full article
(This article belongs to the Special Issue Design, Control and Optimization of Desalination Processes)
Show Figures

Figure 1

Back to TopTop