Sign in to use this feature.

Years

Between: -

Subjects

Journals

remove_circle_outline

Article Types

remove_circle_outline

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = human thermophisiology

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
6 pages, 2042 KiB  
Proceeding Paper
Design, Environment, Energy, and Comfort in Buildings Equipped with a PMV-Controlled HVAC System
by Eusébio Conceição, Margarida Conceição, Maria Inês Conceição, Maria Manuela Lúcio and Hazim Awbi
Eng. Proc. 2023, 53(1), 24; https://doi.org/10.3390/IOCBD2023-15209 - 24 Oct 2023
Cited by 2 | Viewed by 923
Abstract
This work presents a study about the design, environment, energy, and comfort in buildings equipped with a Predicted Mean Vote (PMV)-controlled HVAC system. The control system, based on the three categories of the international standard ISO 7730 uses the level of thermal comfort [...] Read more.
This work presents a study about the design, environment, energy, and comfort in buildings equipped with a Predicted Mean Vote (PMV)-controlled HVAC system. The control system, based on the three categories of the international standard ISO 7730 uses the level of thermal comfort instead of the traditional control of the air temperature. In this type of control, using the PMV index, the air temperature (Tair), air relative humidity (RHair), Mean Radiant Temperature (MRT), air velocity (Vair), level of clothing (CL), and level of physical activity (AL) are considered. The initial four parameters are associated with environmental ones, and the last two are associated with personal ones. The simulation is carried out using a simulator of the dynamic thermal response of buildings and the thermophysiology of the occupants. The simulator considers energy and mass balance integral equations, based on the building’s design. This equation system is generated by the simulator. In this study, three cases are performed: Categories A, B, and C. According to the results obtained, it is possible to verify that it takes some time to achieve acceptable comfort conditions when the HVAC system is connected. However, after the conditions are achieved, the system guarantees acceptable conditions during the occupancy time. Category A provides higher levels of energy consumption than Categories B and C. Full article
(This article belongs to the Proceedings of The 1st International Online Conference on Buildings)
Show Figures

Figure 1

Back to TopTop