Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (1)

Search Parameters:
Keywords = fatigue strenght

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
14 pages, 2282 KiB  
Article
The Role of Biomaterials in Upper Digestive Tract Transoral Reconstruction
by Raluca Grigore, Bogdan Popescu, Şerban Vifor Gabriel Berteşteanu, Cornelia Nichita, Irina Doinita Oașă, Gloria Simona Munteanu, Alexandru Nicolaescu, Paula Luiza Bejenaru, Catrinel Beatrice Simion-Antonie, Dragoș Ene and Răzvan Ene
Materials 2021, 14(6), 1436; https://doi.org/10.3390/ma14061436 - 16 Mar 2021
Cited by 2 | Viewed by 2591
Abstract
This study aims to establish whether the use of biomaterials, particularly polydimethylsiloxane (PDMS), for surgical reconstruction of the esophagus with templates, Montgomery salivary tube, after radical oncology surgery for malignant neoplasia is an optimal choice for patients’ safety and for optimal function preservation [...] Read more.
This study aims to establish whether the use of biomaterials, particularly polydimethylsiloxane (PDMS), for surgical reconstruction of the esophagus with templates, Montgomery salivary tube, after radical oncology surgery for malignant neoplasia is an optimal choice for patients’ safety and for optimal function preservation and organ rehabilitation. Structural analysis by Raman spectrometry and biomechanical properties with dynamic mechanical analysis are performed for fatigue strength and toughness, essential factors in durability of a prosthesis in the reconstruction practice of the esophagus. Nanocomposites with silicone elastomers and nanoparticles used in implantable devices and in reconstruction surgery present risks of infection and fatigue strength when required to perform a mechanical effort for long periods of time. This report takes into account the effect of silver (Ag) nanoparticles on the fatigue strength using polydimethylsiloxane (PDMS) matrix, representative for silicon elastomers used in implantable devices. PDMS with 5% (wt) Ag nanoparticles of 100–150 nm during mechanical fatigue testing at shear strength loses elasticity properties after 400 loading-unloading cycles and up to 15% shear strain. The fatigue strength, toughness, maximum shear strength, as well as clinical properties are key issues in designing Montgomery salivary tube and derivates with appropriate biomechanical behavior for each patient. Prosthesis design needs to indulge both clinical outcomes as well as design methods and research in the field of biomaterials. Full article
(This article belongs to the Special Issue Advanced Materials for Oral Application)
Show Figures

Figure 1

Back to TopTop