Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

remove_circle_outline

Search Results (1)

Search Parameters:
Keywords = Tecnobody Smart Gravity Walker

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
17 pages, 1760 KB  
Article
Sensor-Derived Trunk Stability and Gait Recovery: Evidence of Neuromechanical Associations Following Intensive Robotic Rehabilitation
by Hülya Şirzai, Yiğit Can Gökhan, Güneş Yavuzer and Hande Argunsah
Sensors 2026, 26(2), 573; https://doi.org/10.3390/s26020573 (registering DOI) - 15 Jan 2026
Abstract
This quantitative observational study with pre–post design aimed to examine joint-specific kinematic adaptations and the relationship between trunk stability and spatiotemporal gait parameters following intensive robotic rehabilitation. A total of 12 neurological patients completed 16 sessions of gait training using the Tecnobody Smart [...] Read more.
This quantitative observational study with pre–post design aimed to examine joint-specific kinematic adaptations and the relationship between trunk stability and spatiotemporal gait parameters following intensive robotic rehabilitation. A total of 12 neurological patients completed 16 sessions of gait training using the Tecnobody Smart Gravity Walker. Pre- and post-training kinematic data were collected for bilateral hip and knee flexion–extension, trunk flexion–extension, trunk lateral flexion, and center-of-gravity displacement. Waveforms were normalized to 100% stride. Paired t-tests assessed pre–post differences, and correlations examined associations between trunk stability and gait performance. Significant increases were found in right hip flexion–extension (t = 3.44, p < 0.001), trunk flexion–extension (t = 9.49, p < 0.001), and center-of-gravity displacement (t = 15.15, p < 0.001), with reduced trunk lateral flexion (t = –8.64, p < 0.001). Trunk flexion–extension correlated with gait speed (r = 0.74), step length (r = 0.68), and stride length (r = 0.71); trunk lateral flexion correlated with cadence (r = 0.66) and stride length (r = 0.70). Intensive robotic rehabilitation improved trunk and hip kinematics, supporting trunk stability as an important biomechanical correlate of gait recovery. Sensor-derived metrics revealed strong neuromechanical coupling between postural control and locomotion in neurological patients. Full article
(This article belongs to the Special Issue Sensors and Wearable Device for Gait Analysis)
Show Figures

Figure 1

Back to TopTop