Sign in to use this feature.

Years

Between: -

Subjects

remove_circle_outline
remove_circle_outline
remove_circle_outline

Journals

Article Types

Countries / Regions

Search Results (4)

Search Parameters:
Keywords = POGO scale

Order results
Result details
Results per page
Select all
Export citation of selected articles as:
12 pages, 1051 KB  
Article
A Comparison of the Effectiveness of the McCoy Laryngoscope and the C-MAC D-Blade Video Laryngoscope in Obese Patients
by Jung-Min Lee, Soo-Kyung Lee, Minsoo Jang, Minho Oh and Eun-Young Park
Medicina 2024, 60(8), 1285; https://doi.org/10.3390/medicina60081285 - 9 Aug 2024
Cited by 1 | Viewed by 2937
Abstract
Background and Objective: Obesity is associated with difficult or failed intubation attempts, making general anesthesia challenging for anesthesiologists to perform. The purpose of this study was to evaluate and compare the efficacy of a McCoy laryngoscope and a C-MAC D-blade video laryngoscope for [...] Read more.
Background and Objective: Obesity is associated with difficult or failed intubation attempts, making general anesthesia challenging for anesthesiologists to perform. The purpose of this study was to evaluate and compare the efficacy of a McCoy laryngoscope and a C-MAC D-blade video laryngoscope for intubation in obese patients with a body mass index (BMI) ≥ 35 kg/m2. Methods: In total, 104 patients were randomly assigned to be intubated with a McCoy (McCoy group) or C-MAC D-blade video laryngoscope (C-MAC group). The primary outcome was intubation time. The secondary outcomes were vocal cord exposure time, vocal cord passage time, proportion of successful intubation, mask ventilation scale, intubation difficulty scale (IDS), percentage of glottis opening (POGO) score, and hemodynamic variables. Results: Although the intubation time did not significantly differ, the C-MAC group showed shorter vocal cord exposure times and a higher rate of successful vocal cord exposure within 5 s. The IDS value was significantly lower in the C-MAC group than in the McCoy group. The proportion of patients who required an increase in lifting force during laryngoscopy was higher in the McCoy group than in the C-MAC group, which may explain the difference in MAP between the groups. Conclusions: Both the McCoy laryngoscope and the C-MAC D-blade video laryngoscope were useful during the intubation of obese patients. The C-MAC D-blade video laryngoscope might be more useful for obese patients in terms of hemodynamic stability. Full article
Show Figures

Figure 1

11 pages, 1413 KB  
Article
A Comparison of Miller Straight Blade and Macintosh Blade Laryngoscopes for Intubation in Morbidly Obese Patients
by Pawel Ratajczyk, Przemysław Kluj, Bartosz Szmyd, Julia Resch, Piotr Hogendorf, Adam Durczynski and Tomasz Gaszynski
J. Clin. Med. 2024, 13(3), 681; https://doi.org/10.3390/jcm13030681 - 24 Jan 2024
Cited by 1 | Viewed by 5794
Abstract
The primary objective of this study was to demonstrate whether the Miller blade laryngoscope could provide better visualization of the vocal cords in morbidly obese patients than the Macintosh blade laryngoscope. The secondary objective was to identify the patient-measured factors associated with better [...] Read more.
The primary objective of this study was to demonstrate whether the Miller blade laryngoscope could provide better visualization of the vocal cords in morbidly obese patients than the Macintosh blade laryngoscope. The secondary objective was to identify the patient-measured factors associated with better visualization of the vocal cords when using the Miller vs. Macintosh blade, as well as whether the application of external pressure might improve the visibility of the glottis during intubation. A prospective, observational study encompassing 110 patients with a BMI > 40 undergoing elective bariatric surgery and intubation procedure was performed. The evaluation of the vocal cords was performed according to the Cormack–Lehane scale and POGO scale in the same patient during intubation, performed with a Miller and a Macintosh blade laryngoscope, in a random matter. The following parameters were assessed: body weight, height, BMI, neck circumference, thyromental distance, sternomental distance, mouth opening, and Mallampati scale and their impact on visualization of the vocal cords using the Miller blade without the application of external pressure. The Miller blade provides an improved view of the glottis compared to the Macintosh blade measured with both the Cormac–Lehane scale (45 (40.91%) without external pressure application on the larynx, and 18 (16.36%) with external pressure application on the larynx) and the POGO scale (45 (40.91%) without external pressure application on the larynx, and 19 (17.27%) with external pressure application on the larynx). The application of laryngeal pressure improved the view of the glottis. Among the measured features, a significant improvement in the visibility of the glottis could be found in patients with a BMI over 44.244 kg/m2 and a neck circumference over 46 cm. To conclude, the usage of the Miller blade improves the visibility of the glottis compared to the Macintosh blade in morbidly obese patients. The recommendation to use the Miller blade in this group of patients requires further investigation, taking into account the effectiveness of the intubation. Trial Registration: NCT05494463. Full article
(This article belongs to the Section Anesthesiology)
Show Figures

Figure 1

10 pages, 7441 KB  
Article
Anti-Toothbreaker: A Novel Low-Budget Device Enabling Contactless Dental Protection and a Forbidden Technique during Direct Laryngoscopy for Endotracheal Intubation
by Sam Razaeian and Helena Kristin Liebich
Diagnostics 2023, 13(4), 594; https://doi.org/10.3390/diagnostics13040594 - 6 Feb 2023
Cited by 2 | Viewed by 2857
Abstract
Background: Iatrogenic dental injury is the most common complication of conventional laryngoscopy during orotracheal intubation. The main cause is unintended pressure and leverage forces from the hard metal blade of the laryngoscope. The aim of this pilot study was to introduce and test [...] Read more.
Background: Iatrogenic dental injury is the most common complication of conventional laryngoscopy during orotracheal intubation. The main cause is unintended pressure and leverage forces from the hard metal blade of the laryngoscope. The aim of this pilot study was to introduce and test a novel, reusable low-budget device not only providing contactless dental protection during direct laryngoscopy for endotracheal intubation, but also enabling, in contrast to established tooth protectors, active levering with conventional laryngoscopes for easier visualization of the glottis. Methods: A constructed prototype for intrahospital usage was evaluated by seven participants on a simulation manikin for airway management. Endotracheal intubation was performed with and without the device using a conventional Macintosh laryngoscope (blade size 4) and a 7.5 mm endotracheal tube (Teleflex Medical GmbH, Fellbach, Germany). Necessary time and success of first pass were determined. Degree of visualization of the glottis with and without the device was stated by the participants according to the Cormack and Lehane (CL) classification system and the Percentage of Glottic Opening (POGO) scoring system. In addition, subjective physical effort, feeling of safety regarding successful intubation, and risk for dental injury were queried on a numeric scale between 1 and 10. Results: All participants except one stated that the intubation procedure was easier with usage of the device than without it. On average, this was subjectively perceived as being approximately 42% (range, 15–65%) easier. In addition, time to first pass success, as well as degree of glottis visualization, subjective physical effort, and feeling of safety regarding risk for dental injury, were clearly better with usage of the device. Concerning feeling of safety regarding successful intubation, there was only a minor advantage. No difference in first pass success rate and number of total attempts could be observed. Conclusion: The Anti-Toothbreaker is a novel, reusable low-budget device which might not only provide contactless dental protection during direct laryngoscopy for endotracheal intubation, but also enables, in contrast to established tooth protectors, active levering with conventional laryngoscopes for easier visualization of the glottis. Future human cadaveric studies are needed to investigate whether these advantages also prove themselves there. Full article
(This article belongs to the Special Issue Diagnosis and Management in Trauma Surgery)
Show Figures

Figure 1

10 pages, 1289 KB  
Article
A Comparison of the bébé VieScope™ and Direct Laryngoscope for Use While Wearing PPE-AGP: A Randomized Crossover Simulation Trial
by Pawel Wieczorek, Lukasz Szarpak, Agata Dabrowska, Michal Pruc, Alla Navolokina, Andrzej Raczynski and Jacek Smereka
Children 2022, 9(11), 1774; https://doi.org/10.3390/children9111774 - 18 Nov 2022
Cited by 5 | Viewed by 2353
Abstract
This study aimed to compare the intubation effectiveness of the bébé Vie Scope™ (VieScope) and direct laryngoscopy for emergency intubation in a pediatric manikin model performed by paramedics with and without personal protective equipment for aerosol generating procedures (PPE-AGP). Participants performed endotracheal intubation [...] Read more.
This study aimed to compare the intubation effectiveness of the bébé Vie Scope™ (VieScope) and direct laryngoscopy for emergency intubation in a pediatric manikin model performed by paramedics with and without personal protective equipment for aerosol generating procedures (PPE-AGP). Participants performed endotracheal intubation using VieScope and standard Macintosh laryngoscope (MAC) in two research scenarios: (1) without PPE-AGP, and (2) with PPE-AGP. Fifty-one paramedics without any previous experience with the VieScope participated in this study. In the PPE-AGP scenario, in the VieScope group, the percentage of successful tracheal intubation on the first attempt was higher compared to the MAC group (94.1 vs. 78.4%, p = 0.031), intubation time was shorter (29.8 vs. 33.9 s, p < 0.001), and percentage of glottic opening (POGO) score was higher 91.0 vs 77.8 (p < 0.001). On the Cormack–Lehane scale, intubation with VieScope intubation was associated with higher scores rated at 1 (64.7 vs. 29.4%) than in the MAC group (p = 0.001). For intubation in the non-PPE scenario, there were no statistically significant differences between VieScope and MAC in relation to above parameters. Summarize, the bébé VieScope™ under PPE-AGP wearing conditions has proven to be a useful device for airway management in children providing better visualization of the larynx, better intubation conditions, and a higher success rate of tracheal intubation on the first attempt and reduced intubation time compared to the standard Macintosh laryngoscope. Full article
Show Figures

Figure 1

Back to TopTop