Next Article in Journal
Adverse-Mode FFF: Multi-Force Ideal Retention Theory
Next Article in Special Issue
Determination of Sesquiterpenes in Wines by HS-SPME Coupled with GC-MS
Previous Article in Journal / Special Issue
Recent Developments and Applications of Solid Phase Microextraction (SPME) in Food and Environmental Analysis—A Review
Article Menu

Export Article

From the first issue of 2016, Chromatography has changed its name to Separations.

Open AccessArticle
Chromatography 2015, 2(3), 382-391; doi:10.3390/chromatography2030382

Automated Analysis of Oxytocin by On-Line in-Tube Solid-Phase Microextraction Coupled with Liquid Chromatography-Tandem Mass Spectrometry

School of Pharmacy, Shujitsu University, 1-6-1, Nishigawara, Okayama 703-8516, Japan
*
Author to whom correspondence should be addressed.
Academic Editor: Mary Boyce
Received: 12 May 2015 / Revised: 21 June 2015 / Accepted: 26 June 2015 / Published: 30 June 2015
(This article belongs to the Special Issue Solid Phase Micro-Extraction)
View Full-Text   |   Download PDF [1727 KB, uploaded 30 June 2015]   |  

Abstract

A simple and sensitive method for the analysis of oxytocin was developed using automated on-line in-tube solid-phase microextraction (SPME) coupled with liquid chromatography-tandem mass spectrometry (LC–MS/MS). Oxytocin was separated within 3 min on a Zorbax Eclipse XDB-C8 column, with water/methanol (10/90, v/v) as the mobile phase at a flow rate of 0.2 mL min−1. Electrospray ionization conditions in the positive ion mode were optimized for MS/MS detection by multiple reaction monitoring. The optimum in-tube SPME conditions were 20 draw/eject cycles of 40 µL sample at a flow rate of 250 µL min−1 using a Supel-Q PLOT capillary column as an extraction device. The extracted oxytocin was easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. The calibration curves for oxytocin were linear (r = 0.9981) in the range of 0−5.0 ng mL−1, and the relative standard deviations at each point were below 14.7% (n = 3). The limit of detection of this method was 4.0 pg mL−1, and its sensitivity was 58-fold higher than that of the direct injection method. This method was applied successfully to the analysis of oxytocin in saliva samples without any other interference peaks. View Full-Text
Keywords: in-tube solid-phase microextraction; oxytocin; saliva; liquid chromatography-tandem mass spectrometry in-tube solid-phase microextraction; oxytocin; saliva; liquid chromatography-tandem mass spectrometry
Figures

Figure 1

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0).

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

SciFeed Share & Cite This Article

MDPI and ACS Style

Moriyama, E.; Kataoka, H. Automated Analysis of Oxytocin by On-Line in-Tube Solid-Phase Microextraction Coupled with Liquid Chromatography-Tandem Mass Spectrometry. Chromatography 2015, 2, 382-391.

Show more citation formats Show less citations formats

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Chromatography EISSN 2227-9075 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert
Back to Top