Cardiac Arrhythmias: The Latest Strategies for Clinical Diagnosis and Treatment

A special issue of Journal of Clinical Medicine (ISSN 2077-0383). This special issue belongs to the section "Cardiology".

Deadline for manuscript submissions: 13 June 2024 | Viewed by 139

Special Issue Editors


E-Mail Website
Guest Editor
1. Cardiovascular Research Institute (CVRI) Dublin, Mater Private Hospital, D07 WKW8 Dublin, Ireland
2. Cardiology Department, Tipperary University Hospital, E91 VY40 Clonmel, Ireland
Interests: cardiac arrhythmias; catheter ablation; defibrillators; pacemakers; atrial fibrillation; acute coronary syndrome

E-Mail Website
Guest Editor
Division of Cardiology, Queen’s University, 76 Stuart St, Kingston, ON K7L 2V7, Canada
Interests: cardiovascular; cardiac arrhythmias; catheter ablation; defibrillators; pacemakers; atrial fibrillation

Special Issue Information

Dear Colleagues,

Over the last decade, we have witnessed a true revolutionary era of new technologies in regard to ablations strategies. For most of these technologies, the focus is on generating a high-standard safety profile for patients and effective (ablation) strategies.

In regard to energy delivery, conventional radiofrequency ablations have been developed from primitive parameters as impedance drop or EGMs changes with ablations to the use of a forced time integral as a marker for effective lesions, and then moving them to the superior one of the ablation index parameters. Recently, there have been new developments in terms of short-duration, high-power RF ablation. There is no doubt that each technology provides a new horizon in order to improve efficacy, ensure safety, and improve procedures time, radiation exposure, etc.

Within the era of cryoablation, where electrical block lines are created through freezing the tissue to a certain degree to create ablated cells and damage cascade to create bidirectional electrical blocks, this technology showed itself to be superior in terms of saving time during the procedure at a slight cost of certain complications that are marginally higher than those experienced with radiofrequency ablation. However, many trials are needed to confirm the equal efficacy and safety of this method.

A novel pulse field ablation via the electroporation of cells is considered to be the future for ablations, where the beam of the electric shock wave will initiate a cascade for programmed cell death, hence the line of the block. The advantages include a very short duration procedure time and homogenous and intact ablation lesions and lines, with an overall improvement in the procedures time and impact on patient recovery. The potential side effects are almost similar to former technologies. The technical aspects for the best approach to use this new technology are evolving and are currently a source for future research.

Dr. Usama Boles
Dr. Andres Enriquez
Guest Editors

Manuscript Submission Information

Manuscripts should be submitted online at www.mdpi.com by registering and logging in to this website. Once you are registered, click here to go to the submission form. Manuscripts can be submitted until the deadline. All submissions that pass pre-check are peer-reviewed. Accepted papers will be published continuously in the journal (as soon as accepted) and will be listed together on the special issue website. Research articles, review articles as well as short communications are invited. For planned papers, a title and short abstract (about 100 words) can be sent to the Editorial Office for announcement on this website.

Submitted manuscripts should not have been published previously, nor be under consideration for publication elsewhere (except conference proceedings papers). All manuscripts are thoroughly refereed through a single-blind peer-review process. A guide for authors and other relevant information for submission of manuscripts is available on the Instructions for Authors page. Journal of Clinical Medicine is an international peer-reviewed open access semimonthly journal published by MDPI.

Please visit the Instructions for Authors page before submitting a manuscript. The Article Processing Charge (APC) for publication in this open access journal is 2600 CHF (Swiss Francs). Submitted papers should be well formatted and use good English. Authors may use MDPI's English editing service prior to publication or during author revisions.

Keywords

  • cardiac arrhythmias
  • catheter ablation
  • defibrillators
  • pacemakers
  • atrial fibrillation
  • acute coronary syndrome

Published Papers

This special issue is now open for submission.
Back to TopTop