Next Article in Journal
Estimation of Fine Particulate Matter in Taipei Using Landuse Regression and Bayesian Maximum Entropy Methods
Next Article in Special Issue
Assessing Environmental Risks for Established Invasive Weeds: Dalmatian (Linaria dalmatica) and Yellow (L. vulgaris) Toadflax in North America
Previous Article in Journal
Effect of Discontinuation of Fluoride Intake from Water and Toothpaste on Urinary Excretion in Young Children
Previous Article in Special Issue
Spatial Multicriteria Decision Analysis of Flood Risks in Aging-Dam Management in China: A Framework and Case Study
Int. J. Environ. Res. Public Health 2011, 8(6), 2142-2152; doi:10.3390/ijerph8062142

Bystander Exposure to Ultra-Low-Volume Insecticide Applications Used for Adult Mosquito Management

*  and
Department of Land Resources and Environmental Sciences, Montana State University, 334 Leon Johnson Hall, Bozeman, Montana 59717, USA
* Author to whom correspondence should be addressed.
Received: 26 April 2011 / Revised: 4 June 2011 / Accepted: 9 June 2011 / Published: 14 June 2011
(This article belongs to the Special Issue Environmental Health Risk Assessment)
View Full-Text   |   Download PDF [296 KB, uploaded 19 June 2014]   |   Browse Figures


A popular and effective management option for adult mosquitoes is the use of insecticides applied by ultra-low-volume (ULV) equipment. However, there is a paucity of data on human dermal exposure to insecticides applied by this method. The objective of the current study was to estimate dermal exposures to the insecticide active ingredient permethrin using water- (Aqua-Reslin®) and oil-based (Permanone® 30-30) formulations with passive dosimetry. No significant differences in deposition of permethrin were observed between years, distance from the spray source, front or back of the body, or the placement of the patches on the body. However, exposure to Aqua-Reslin was significantly greater than Permanone 30-30 and average concentrations deposited on the body were 4.2 and 2.1 ng/cm2, respectively. The greater deposition of Aqua-Reslin is most likely due to the higher density of the water-based formulation which causes it to settle out faster than the lighter oil-based formulation of Permanone 30-30. The estimated average absorbed dermal exposure for permethrin from Aqua-Reslin and Permanone 30-30 was 0.00009 and 0.00005 mg/kg body weight, respectively. We also found that ground deposition of ULV insecticides can be used as a surrogate for estimating dermal exposure. The estimated exposures support the findings of previous risk assessments that exposure to ULV applications used for mosquito management are below regulatory levels of concern.
Keywords: dermal exposure; pyrethroid; risk analysis; exposure assessment; passive dosimetry dermal exposure; pyrethroid; risk analysis; exposure assessment; passive dosimetry
This is an open access article distributed under the Creative Commons Attribution License (CC BY) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Share & Cite This Article

Further Mendeley | CiteULike
Export to BibTeX |
MDPI and ACS Style

Preftakes, C.J.; Schleier III, J.J.; Peterson, R.K. Bystander Exposure to Ultra-Low-Volume Insecticide Applications Used for Adult Mosquito Management. Int. J. Environ. Res. Public Health 2011, 8, 2142-2152.

View more citation formats

Related Articles

Article Metrics

For more information on the journal, click here


Cited By

[Return to top]
Int. J. Environ. Res. Public Health EISSN 1660-4601 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert