1. Introduction
Nowadays, many small communities located in rural or isolated areas of Spain lack adequate domestic wastewater treatment facilities. In these areas, wastewater collection and its treatment via public sewage systems are problematic due to the widely dispersed population. Wastewater treatment by traditional on-site systems, like septic tank/soil absorption design, is common in southeastern Spain because the land in this area is well-suited for percolation. However, these practices pose risks because percolated wastewater can contaminate groundwater with pollutants such as nitrates and phosphates, resulting in serious environmental damage. Consequently, these communities or individual households have to use alternative wastewater treatment technologies. One example of these areas is the countryside of Elche, Alicante (Spain). It is located on the aquifer, “080.190 Bajo Vinolopó,” certified as permeable. The aquifer has average nitrate content of 61.5 mg·L
−1 [
1] that exceeds the Spanish legal limit by 23% [
2]. According to Spanish law [
3], it is not a sensitive area, but it is listed as vulnerable to pollution by nitrates from agricultural sources [
4].
With respect to proper wastewater treatment, the European Union (EU) Directive [
5] and the EU Water Framework Directive [
6], establish a series of requirements for effluents of wastewater treatment plants, as well as for the abatement efficiency (
Table 1) that must be applied to populations greater than 2000 population equivalent (PE) (“1 PE means the organic biodegradable load has a five-day biochemical oxygen demand (BOD
5) of 60 g of oxygen per day”) and an “adequate treatment” requirement for populations lower than 2000 PE. The wastewater can be discharged into sensitive areas (areas that are eutrophic or close to it) or into non-sensitive areas (in no danger of eutrophication). BOD
5, chemical oxygen demand (COD), and total suspended solids (TSS) should be monitored in non-sensitive areas, whereas for sensitive areas, in addition to the parameters cited for non-sensitive areas, total nitrogen (TN) and total phosphorous (TP) should also be monitored. Proper treatment for wastewater from populations lower than 2000 PE is unspecified, so contaminants and limits are usually evaluated according to the legislation designed for populations greater than 2000 PE. In addition, the EU Directive [
5] established a plan which seeks to boost the incorporation and use of, among other things, low-cost solutions to provide wastewater treatment to small communities, and comparative studies of nutrient abatement for populations with fewer than 2000 PE.
As an alternative to conventional wastewater treatment plants, constructed wetlands (CWs) prove to be much more cost-efficient, especially for low population areas. CWs are relatively simple systems in comparison to conventional wastewater treatments plants, formed by various beds of different particle sizes, such as sand or gravel, planted with macrophites whose roots support the microbial bioburden essential for contaminant abatement in surface water, groundwater or waste streams [
7]. They are designed to make use of similar processes that are carried out in natural wetlands, but do so within a closely monitored environment [
8,
9]. CWs have been used for more than 50 years in various parts of the world, and it is likely that more than 100,000 CWs worldwide currently treat over one billion liters of water a day [
10]. The estimated cost for wastewater treatment using CWs ranges between 186 and 357 US$ m
−3 compared with conventional treatment processes ranging between 571 and 715 US$ m
−3 [
11]. Besides the aforementioned cost-efficiency, CWs have many other benefits. They are simple to operate, robust, use natural treatment processes, and provide aesthetic value. They also produce beneficial biomass through the different kinds of plants grown on them in addition to helping support wildlife habitats [
11].
As for their efficacy, horizontal subsurface flow constructed wetlands (HF-CWs) have been successfully employed to abate key contaminants from wastewater, such as the organic load, nutrients (mainly N and P), and pathogens [
12,
13], as well as to restore ecosystems [
14]. A large number of physicochemical and biological processes are involved in these systems [
15] such as sedimentation, filtration, precipitation, sorption, plant uptake, and microbial decomposition [
16]. The rate of these processes may vary according to the geographical area and the season of the year, and they depend on many factors such as the organic loading, the depth of the water and the availability of electron acceptors [
17]. In addition, abatement efficiencies can be affected in complex ways by the annual cycles of numerous parameters, such as the quality and quantity of water, soil, air temperature, solar radiation, humidity, precipitation, influent pollutant concentrations, or vegetation. For this reason, it is very important to consider the climate in which the CWs are constructed.
Our research aimed to investigate the efficacy of a HF-CW under the climatic conditions of southeastern Spain. To the best of our knowledge, there are few studies on the performance of CWs in Mediterranean Spain, although HF-CWs are one of the most commonly used types in Europe. HF-CWs are a relatively new technology in Spain and, until recently, only a small number of HF-CWs had been reported, distributed mainly in the Mediterranean area [
18,
19]. As the CW surface is related to contaminant abatement efficiency, it is necessary to find the optimal design in order to maximize abatement efficiency, while keeping the area to a minimum. In this respect, hydraulic retention time (
HRT), reference evapotranspiration (
ET0) and temperature (
T) are the parameters that most determine the efficiency [
11,
20].
This paper presents the results obtained during the first two operation years of an HF-CW that had been previously built by a private company according their own design protocol. The main aim was to monitor the efficiency of this HF-CW under the climatic conditions of southeastern Spain, and to service an individual household for the abatement of the key physical and chemical contaminants established by EC [
5] and adopted by Spain. As consequence of the results obtained, a theoretical redesign of the HF-CW is proposed in order to achieve the minimum area for optimal contaminant abatement efficiency.
3. Results and Discussion
3.1. Water Influent and Effluent Characterization
The measured average daily Qin was 0.27 m3. Considering this Qin, the water depth (d) (0.6 m), assuming an average porosity (n) of 0.38, corresponding to the cross section not occupied by vegetation and the wetland area (As) (27 m2), the HRT (HRT = As·d·n/Q) and hydraulic loading rate (HLR = 100·Q/As) values of 22.6 d and 1 cm·d−1, respectively, were calculated.
Average values for the wastewater quality parameters (influent and effluent), the efficiency of treatment for the two years studied and the legal limits for discharge are given in
Table 1.
Pollutant values found at the influent wastewaters are higher compared to other geographical zones [
29]. These data agree with those reported by Puigagut, Villaseñor, Salas, Bécares and García [
18] and may relate to the water-saving practices followed by citizens in southeastern Spain, an area with a dry Mediterranean climate and prolonged droughts; as a result, the concentration of contaminants in domestic wastewaters are higher. An experiment run in a semi-arid zone of Tunisia showed even higher values [
30].
3.2. Abatement of Organic Matter
Effluent BOD
5 concentration showed small variations through the first year (
Figure 2a), with an average value of 13.2 ± 5.3 mg·L
−1 and an abatement of 96.4% ± 1.8% (
Table 1). The drop observed in June 2013 could be explained by the high vegetative growth of common reed that implies a proper working of the CW, and because T increase favours a lower oxygen demand [
31].
In July and August of 2013, BOD
5 sampling could not be performed due to the insufficient level of water at the outlet manhole (
Qout = 0 m
3). Generally,
Qout can be deduced from Equations (2) and (3) in function of the HF-CW area. If the
Qout obtained is negative, as occurred in the 27 m
2 HF-CW of this study (
Table 2), a partial drying of the HF-CW bed may occur.
These observations are in accordance with data obtained in zones of similar climatic characteristics in Morocco [
32]. As a result of this drying episode, the following months showed an abnormal behavior for the BOD
5 value, a circumstance that can be related to the possible formation of preferential flow paths in the HF-CW bed that would have decreased the HRT. Other authors reported that an excessive root growth may cause the unbundling of the bed, encourage the creation of preferred paths and short circuits and open new pore spaces in the substrate [
30,
33]. From December 2013, a tendency to return to the proper working order of the CW was observed. This nonlinear behavior of BOD
5 data may also be related to an oversized HF-CW and, therefore, we consider it necessary to resize the system, as will be discussed in
Section 4. Despite the aforementioned, the mean BOD
5 value in this period was 25.4 ± 12.4 mg·L
−1, slightly higher than the maximum level permitted, but with a reduction (92.0% ± 4.4%) well over the values recommended by EC [
5].
Table 3 shows the abatement efficiencies found in experiments run in some Mediterranean countries using HF-CWs systems, compared to the surface PE
−1. Although PE definition has been already introduced in
Section 1, in this ratio, a consumption of 250 L of water per person per day is assumed to obtain adequate comparison units [
34]. Our results agree with those of higher BOD
5 abatement; oversizing of the system could explain these values. On the other hand, the climate of the Mediterranean basin, which implies warmer T of the water and, during growing season, the larger and constant growth of the common reed, may justify the high abatement found for this region compared with other European experiences [
35].
The abatement process of BOD
5 is mainly carried out by bacterial activity (aerobic and anaerobic) with greenhouse gases production and emission to the atmosphere [
41,
42], and by the sedimentation and filtration of particulate organic matter [
43]. In this respect the assisted aeration during the first year of the study combined within common reed activity was effective [
44].
Similarly to BOD
5, effluent COD concentrations showed a stable value for the first years, with a COD mean value of 102.1 ± 13.5 mg·L
−1 and 84.6% ± 4.0% abatement. As result of the partial drying of the HF-CW in July and August 2013, the possible appearance of preferential water paths can be responsible for abnormal and high COD values (
Figure 2b). When the water regime returned to normal (final study period), COD tended to recover values of the same order as for the initial period. Although the percentage of abatement in this last period (77.7% ± 9.4%) was slightly higher than the directive’s limit [
5], it was similar to those obtained in other experiments in similar Mediterranean climate zones (
Table 3).
The abatement mechanisms of COD are similar to those for BOD
5 and depend on the combination between physical and microbial mechanisms. The physical filtration mechanism is related to the small pore size of the filler material; so the organic solids could be trapped in the bed of HF-CWs for a long time allowing biodegradation of organic solids [
11].
The ratio BOD
5/COD is related to the biodegradability of the organic matter present in the water, or the ability of some organic chemicals that can be used as substrates by microorganisms to produce energy (cellular respiration) and create other substances such as amino acids, tissues and organisms [
29]. In our experiment, the ratio BOD
5/COD for influent wastewaters had an average of 0.53 ± 0.08, a characteristic value for water of high biodegradability; while HF-CW effluents had an average of 0.15 ± 0.06, indicative of low biodegradability.
Taking into account that BOD
5/COD in untreated municipal wastewaters is between 0.3 and 0.8, and that this relationship changes to 0.4–0.6 after the primary sedimentation, and decreases to 0.1–0.3 after secondary treatments [
45], we could conclude that the HF-CW studied behaves as a secondary water treatment system. This affirmation is consistent with the data from other wastewater treatment experiences [
46].
3.3. Abatement of Total Suspended Solids (TSS)
The temporal evolution of TSS in both influent and effluent wastewaters of HF-CW is given in
Figure 3. The drying episode mentioned was also reflected in the TSS parameter. Therefore, during the first year, effluent TSS mean value was only 8.8 ± 4.0 mg·L
−1 with an abatement of 94.8% ± 2.4%, and a slight increase in June 2013 previous to the drying. The first months of the second year showed anomalous data, followed by a tendency to recover the levels of the first year, including an increase in June 2014, once the CW was recovered to a normal water regime.
TSS abatement mainly occurs through filtration and sedimentation, a process favored by macrophyte roots that reduce the water speed [
7]. Water pretreatment is also very important to prevent the rapid clogging of the CW bed. Rousseau et al. [
32] reported that clogging is a tangible risk in subsurface flow constructed wetlands and is principally influenced by loading rates of BOD
5 and/or TSS, the HLR, the particle size and distribution of the matrix material as well as the wastewater particles. This phenomenon can be counteracted by lowering HLR or by letting the bed rest. During this resting period, organic material that blocks the pores can be composted and the hydraulic conductivity thus restored. In our experience, the HF-CW took a full year to recover operating conditions after the drying episode. Our data are in accordance with the literature and demonstrate the effectiveness of HF-CW in TSS abatement in Mediterranean climate zones (
Table 3) and attainment of suitable effluents for discharge according to Spanish law.
3.4. Abatement of Nitrogenous Compounds
The TN content in the wastewater is the sum of the N present in both organic and inorganic forms. Among the first ones are amino acids, urea, uric acids and nitrogenous bases; inorganic forms are NH
4+-N, NO
2−-N, NO
3−-N and gaseous nitrogen that includes NH
3, N
2, NO
2 and N
2O. Therefore the evolution of the TN parameter is linked to the transformation between these different forms, their selective absorption by plants and the volatilization of the gaseous forms [
12].
In CWs, organic N undergoes a series of transformations that are related to their mechanisms of abatement. The first stage would be ammonification which transforms organic N into NH
4+-N following the pathway: amino acids−imino acids−keto acids−ammonium. In a second stage, NH
4+-N is converted by bacteria into NO
2−-N and NO
3−-N in the presence of oxygen. The interconversions between different forms of TN are associated with abatement mechanisms such as assimilation by plants, volatilization of gaseous forms and adsorption by cation exchange. A detailed review on the dynamics of N in HF-CWs is given by Saeed and Sun [
47].
The average percentage of nitrogen forms in the influent wastewater, with respect to TN, was: organic N (20.8% ± 5.9%), NH4+-N (77.6% ± 5.8%), NO3−-N (1.4% ± 0.7%) and NO2−-N (0.2% ± 0.0%).
3.4.1. Abatement of Total Nitrogen
The evolution of the TN content in the influents and effluents of the HF-CW studied is shown in
Figure 4a. During the first year, the influent wastewaters showed an average content of 142.7 ± 11.8 mg·L
−1, while in the effluents, it was 29.3 ± 8.3 mg·L
−1, with a minimum of 6.0 mg·L
−1 in June 2013. The time evolution showed a decrease of TN content at the beginning of the experience, coinciding with the start of vegetative growth, followed by stabilization, around 30 mg·L
−1, until the CW desiccation occurred.
Once the normal water regime was restored, a non-linear response was observed. This abnormal behavior could be due to different causes. On the one hand, accumulation of TN and a change of microbiological population of the bed may occur. On the other hand, the rainfall effects or the non-homogeneous influent TN concentration may also have an influence. A detailed study would be needed but, in any case, preventing desiccation of the HF-CW bed is convenient as will be discussed in
Section 4. This behavior was also observed for NH
4+-N and NO
3−-N (
Figure 4b,c). At the end of the experience, TN abatement efficiency returned to the values found during the first year, in which there was a normal water regime. The mean percentage abatement for TN during the first year was 79.5% ± 5.6%, reaching 95.7% (June 2013), meeting the legal limit values for wastewater discharge into sensitive areas [
5].
Because the ammonification and nitrification steps involve lower acidity while denitrification increases the pH, the small change detected (
Table 1), mainly at the stage of correct system operation, can be interpreted as a balance between these processes in the CW. Moreover, the pH value during all the experiment was not a limiting factor on the proliferation of microbiological population involved in the above processes.
Our data for TN abatement show a higher efficiency than others found in Mediterranean countries (
Table 3), probably due to oversizing the system and the application of assisted aeration during the first year. HF-CWs are considered an anoxic system; therefore, the assisted aeration during the first steps of the development of CW bed can play an important role, because the incipient plant growth cannot provide enough oxygen. Once the plants are well developed they are able to mobilize and inject oxygen through the roots, from 0.005 to 12 g·O
2·m
−2·d
−1, depending on the density of planting [
47,
48]. Thus,
Phragmites australis roots provide support and oxygen source for microorganisms involved in nitrification and denitrification processes occurring in the anoxic zones [
49]. Taking into account these considerations, the depth of subsurface constructed wetland should be linked to the maximum development of the macrophyte roots, 60 cm in the case of
Phragmites australis [
50].
3.4.2. Abatement of Ammonium Nitrogen
Figure 4b shows the evolution of NH
4+-N throughout the experiment. NH
4+-N represents most of the N in domestic wastewater [
29], and a similar composition was observed for the influent wastewater (77.6% ± 5.8%). During the first year, mean values for the influents and the effluents were 109.2 ± 9.9 mg·L
−1 and 1.4 ± 1.1 mg·L
−1, respectively. This represents over 98.8% ± 0.9% abatement, confirming that CWs transforms almost all of the NH
4+-N. After drying, erratic data were found with some very high values: 29.2 ± 3.2 mg·L
−1 in October 2013 or 25.2 ± 2.9 mg·L
−1 in January 2014; however, abatement rates remain high with an average around 86%. At the end of the experience a recovery of the operating conditions of the HF-CW (possible disappearance of preferential pathways) was observed, and the values decreased progressively towards the average value of the first year.
HF-CW experiment run in Mediterranean areas showed an NH
4+-N abatement of between 9% and 76% (
Table 3). The range is extensive, and can be related to the specific conditions of each CW. In our case, the high values found may be due to the large area of the HF-CW and assisted aeration during the first year.
3.4.3. Abatement of Nitrate Nitrogen
NO
3−-N evolution in the influents and the effluents of HF-CW is shown in
Figure 4c. In the influent wastewaters, NO
3−-N content was almost constant throughout the experiment, with an average value of 2.2 ± 1.2 mg·L
−1. However, data of the effluents revealed the capacity of the HF-CW for transformation between different N forms. Therefore, during the first year, the data showed an intense nitrification process, mainly from NH
4+-N (nitrogenous form in greater proportion in the influent wastewater), with an average value of 22.6 ± 10.5 mg·L
−1; while the minimum and maximum was 2.9 ± 0.4 mg·L
−1 and 46.4 ± 3.1 mg·L
−1, respectively. The drop in June for both years can be attributed to a high intake by the reeds, which were well developed at this time. When all the influent water was consumed by
Phragmites australis, an erratic behavior for NO
3−-N content was observed and preferential flow paths for the water may have appeared.
The high level of nitrification in the initial stage of the CW may be related to the artificial aeration of influent wastewater during the first year of operation. The nitrification process continued despite the fact that forced aeration was stopped, a circumstance that can be attributed to the large amounts of oxygen injected by the roots of Phragmites australis into the bed of the CW. However, it should be noted that the oxygenation produced by common reed depends on the depth reached by the roots and the HRT.
3.4.4. Abatement of Nitrite Nitrogen
During the first year, NO
2−-N concentrations in the effluents were very low (
Figure 4d), near to the detection limits of the analytical method used (0.3 mg·L
−1); small differences were observed between the influent/effluent water. In the CWs, NO
2−-N may appear as an intermediate in the reactions of nitrification, denitrification, and NO
3−-N reduction [
47]. Thus, the low NO
2−-N content can be explained by the preferential oxidation process from NO
2−-N to NO
3−-N favored by the oxygen supply; in fact, this oxidation is only inhibited when the dissolved oxygen is lower than 2.5 mg·L
−1 [
51]. Besides, there is an alkalinity requirement for nitrification and, if the HF-CW bed is not alkaline enough, an increase in NO
2−-N concentration may occur. Below 25 °C, the growth rate of NH
4+-N-oxidizing bacteria (NH
4+-N to NO
2−-N conversion) is lower than nitrite-oxidizing bacteria (NO
2−-N to NO
3−-N conversion). Throughout the experiment, wastewater T inside the HF-CW was below 25 °C, with the lowest ones between 13.6 and 16.7 °C in winter; this would be in accordance with the small NO
2−-N concentrations found [
52].
After CW drying, an increase of NO2−-N in water effluent was observed, which can be interpreted as an increase of NO3−-N reduction in the anaerobic bed zones not affected by preferential path flow. Once the water flow was stabilized again, the NO2−-N content tended to recover the standard values of the first year.
3.5. Abatement of Total Phosphorus
Figure 5 shows the evolution of the TP in the CW. Influent wastewaters had a TP mean value of 19.2 ± 4.2 mg·L
−1; maximum value was reached in October 2012 (30.0 ± 1.7 mg·L
−1) and minimum in November 2013 (14.2 ± 0.9 mg·L
−1). The variability was related to the home consumption of water by a reduced number of residents.
No great differences were found in TP concentration in the wastewater effluents when considering the total sampling period, or the two periods separated by the drying episode. For the whole of the experiment, the mean value was 3.0 ± 0.6 mg·L−1, with maximum and minimum of 3.8 ± 0.2 mg·L−1 and 1.3 ± 0.1 mg·L−1, respectively; whereas the mean values were 3.2 ± 0.4 mg·L−1 and 2.9 ± 0.7 mg·L−1 for the first and second year, respectively, when data are considered separately.
The CW showed a slight increase in disposal capacity of TP from the beginning of its operation until the dryness episode. Nevertheless, the percentage abatement regarding influent wastewaters exceeded 80% in all cases: 83.7% ± 2.8% and 82.8% ± 4.9% (
Table 1) for the first and second year, respectively. In investigations run in similar Mediterranean countries, the TP reduction ranged between 15% and 63% (
Table 3); higher values found in our experiment may be due to oversizing of the HF-CW, which provokes a larger surface substrate-water contact.
The ability of CWs to retain P depends on the phosphorus HLR, the type of substrate bed, vegetation and the HRT [
53]. The abatement of TP is linked to different mechanisms. On the one hand, the mineral components of the bed, sand and gravel lead to adsorption and precipitation reactions of P with Ca, Al and Fe ions [
54]. Few investigations have been made regarding the saturation of the mineral filler, but it decreases significantly after a period of 5–6 years [
55,
56]. Mineralized peat can also adsorb P by means of an unclear process when its concentration is higher than 1.5 mg·L
−1 [
57]. However, the only sustainable mechanism for TP removal is plant uptake and subsequent harvesting. It has been accepted traditionally that the amount of P that can be abated by harvesting constitutes only an insignificant fraction of the amount of the P load in the system [
58], but recently it has been demonstrated that a well-developed
Phragmites australis can assimilate up to 75.1% of total dissolved P influent [
14].
The regulatory requirements in the area where the HF-CW was located did not include TP as a parameter to be monitored in the water because it is a non-sensitive area; nevertheless, if TP control were required, as occurs in sensitive areas, the effluents also comply with the Spanish law (80% abatement was achieved).
5. Conclusions
The horizontal subsurface flow constructed wetland (HF-CW) for the treatment of domestic wastewater evaluated under the climatic conditions of southeastern Spain meets the legal requirements for conducting discharges. Nevertheless, and taking into account the influent water volume and the climatic conditions of an area with a high evapotranspiration in the summer season, the surface of the wetland studied was excessive and caused the drying of the bed, which induced an anomalous behavior with the possible apparition of preferential flow paths during the ensuing months.
To redesign the HF-CW surface in order to optimize the abatement performance considering the actual conditions of the area, biochemical oxygen demand over five days (BOD5) is the parameter that must be considered due to its impact and the fact that the Elche countryside is not a sensitive area. Reed’s equations were useful for re-sizing, and the results showed that the studied system was 5.2 times oversized.
If P abatement is required, as in some sensitive areas, the required sizing would lead to an excessive surface that would lead to drying episodes, considering the high evapotranspiration in the area. In these cases, complementary treatments, like the use of slags or “irregularly shaped” HF-CWs, will be required.