Next Article in Journal
Previous Article in Journal
Sensors 2011, 11(6), 6257-6269; doi:10.3390/s110606257
Article

Implementation of the CMOS MEMS Condenser Microphone with Corrugated Metal Diaphragm and Silicon Back-Plate

1,2
, 3
, 3
, 3
, 3
, 3
, 2
, 2
, 1
 and 1,*
Received: 21 April 2011; in revised form: 30 May 2011 / Accepted: 31 May 2011 / Published: 10 June 2011
(This article belongs to the Section Physical Sensors)
View Full-Text   |   Download PDF [1265 KB, updated 21 June 2014; original version uploaded 21 June 2014]
Abstract: This study reports a CMOS-MEMS condenser microphone implemented using the standard thin film stacking of 0.35 μm UMC CMOS 3.3/5.0 V logic process, and followed by post-CMOS micromachining steps without introducing any special materials. The corrugated diaphragm for the microphone is designed and implemented using the metal layer to reduce the influence of thin film residual stresses. Moreover, a silicon substrate is employed to increase the stiffness of the back-plate. Measurements show the sensitivity of microphone is −42 ± 3 dBV/Pa at 1 kHz (the reference sound-level is 94 dB) under 6 V pumping voltage, the frequency response is 100 Hz–10 kHz, and the S/N ratio >55 dB. It also has low power consumption of less than 200 μA, and low distortion of less than 1% (referred to 100 dB).
Keywords: CMOS-MEMS; condenser microphone; corrugated; sensitivity; diaphragm CMOS-MEMS; condenser microphone; corrugated; sensitivity; diaphragm
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Export to BibTeX |
EndNote


MDPI and ACS Style

Huang, C.-H.; Lee, C.-H.; Hsieh, T.-M.; Tsao, L.-C.; Wu, S.; Liou, J.-C.; Wang, M.-Y.; Chen, L.-C.; Yip, M.-C.; Fang, W. Implementation of the CMOS MEMS Condenser Microphone with Corrugated Metal Diaphragm and Silicon Back-Plate. Sensors 2011, 11, 6257-6269.

AMA Style

Huang C-H, Lee C-H, Hsieh T-M, Tsao L-C, Wu S, Liou J-C, Wang M-Y, Chen L-C, Yip M-C, Fang W. Implementation of the CMOS MEMS Condenser Microphone with Corrugated Metal Diaphragm and Silicon Back-Plate. Sensors. 2011; 11(6):6257-6269.

Chicago/Turabian Style

Huang, Chien-Hsin; Lee, Chien-Hsing; Hsieh, Tsung-Min; Tsao, Li-Chi; Wu, Shaoyi; Liou, Jhyy-Cheng; Wang, Ming-Yi; Chen, Li-Che; Yip, Ming-Chuen; Fang, Weileun. 2011. "Implementation of the CMOS MEMS Condenser Microphone with Corrugated Metal Diaphragm and Silicon Back-Plate." Sensors 11, no. 6: 6257-6269.


Sensors EISSN 1424-8220 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert