Next Article in Journal
Basic Research in Human–Computer–Biosphere Interaction
Next Article in Special Issue
Seismic Collapse Assessment of a 20-Story Steel Moment-Resisting Frame Structure
Previous Article in Journal
Scenario Testing of the Energy and Environmental Performance of “The Glasgow House”
Previous Article in Special Issue
Self-Centering Seismic Lateral Force Resisting Systems: High Performance Structures for the City of Tomorrow
Article Menu

Export Article

Open AccessArticle
Buildings 2014, 4(4), 605-634; doi:10.3390/buildings4040605

Performance Evaluation of Different Masonry Infill Walls with Structural Fuse Elements Based on In-Plane Cyclic Load Testing

1
Barnhart Crane and Rigging Company, Monroe, MI 48161, USA
2
Department of Architectural Engineering and Department of Civil and Environmental Engineering, The Pennsylvania State University, University Park, PA 16802, USA
*
Author to whom correspondence should be addressed.
Received: 27 June 2014 / Revised: 4 September 2014 / Accepted: 9 September 2014 / Published: 26 September 2014
(This article belongs to the Special Issue Seismic-Resistant Building Design)

Abstract

This paper discusses the performance of a structural fuse concept developed for use as a seismic isolation system in the design and retrofit of masonry infill walls. An experimental program was developed and executed to study the behavior of the structural fuse system under cyclic loads, and to evaluate the performance of the system with various masonry materials. Cyclic tests were performed by applying displacement controlled loads at the first, second, and third stories of a two-bay, three-story steel test frame with brick infill walls; using a quasi-static loading protocol to create a first mode response in the structural system. A parametric study was also completed by replacing the brick infill panels with infill walls constructed of concrete masonry units and autoclaved aerated concrete blocks, and applying monotonically increasing, displacement controlled loads at the top story of the test frame. View Full-Text
Keywords: masonry infill walls; seismic isolation; cyclic lateral load testing; structural fuse masonry infill walls; seismic isolation; cyclic lateral load testing; structural fuse
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0).

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

SciFeed Share & Cite This Article

MDPI and ACS Style

Kauffman, A.; Memari, A.M. Performance Evaluation of Different Masonry Infill Walls with Structural Fuse Elements Based on In-Plane Cyclic Load Testing. Buildings 2014, 4, 605-634.