Next Article in Journal
A Review of Thiosulfate Leaching of Gold: Focus on Thiosulfate Consumption and Gold Recovery from Pregnant Solution
Previous Article in Journal
Effect of the Temperature in the Mechanical Properties of Austenite, Ferrite and Sigma Phases of Duplex Stainless Steels Using Hardness, Microhardness and Nanoindentation Techniques
Previous Article in Special Issue
Preparation and Characterization of Aminated Hydroxyethyl Cellulose-Induced Biomimetic Hydroxyapatite Coatings on the AZ31 Magnesium Alloy
Article Menu
Issue 6 (June) cover image

Export Article

Open AccessArticle
Metals 2017, 7(6), 220; doi:10.3390/met7060220

TiO2 Nanotubes on Ti Dental Implant. Part 2: EIS Characterization in Hank’s Solution

Department of Chemical Engineering, Materials and Industrial Production, University of Napoli, Piazzale Tecchio 80, 80125 Napoli, Italy
*
Author to whom correspondence should be addressed.
Received: 18 May 2017 / Revised: 6 June 2017 / Accepted: 12 June 2017 / Published: 14 June 2017
View Full-Text   |   Download PDF [3551 KB, uploaded 15 June 2017]   |  

Abstract

Titania nanotubes are widely studied for their potential applications in several fields. In this paper, the electrochemical characterization of a dental implant, made of commercially pure titanium grade 2, covered by titania nanotubes, when immersed in Hank’s solution, is proposed. Few papers were found in the scientific literature regarding this topic, so a brief review is reported, concerning the use of some equivalent circuits to model experimental data. The analysis of results, obtained by using Electrochemical Impedance Spectroscopy, showed that: (i) a good correlation exists between the variation of Ecorr and the estimated values of the charge transfer resistance for both the bare- and the nanotube-covered samples, (ii) the nanostructured surface seems to possess a more active behaviour, while the effect could be over-estimated due to the real extent of the surface covered by nanotubes, (iii) the analysis of the “n” parameter, used to fit the experimental data, confirms the complex nature of nanostructured layer as well as that the nanotubes are partially filled by compounds containing Ca, P and Mg, when immersed in Hank’s solution. The results obtained in this work give a better understanding of the electrochemical behaviour of the nanotubes layer when immersed in Hank’s solution and could help to design a surface able to improve the implant osseointegration. View Full-Text
Keywords: dental implant; titanium nanotubes; EIS; Hank’s solution dental implant; titanium nanotubes; EIS; Hank’s solution
Figures

Figure 1

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0).

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

SciFeed Share & Cite This Article

MDPI and ACS Style

Monetta, T.; Acquesta, A.; Carangelo, A.; Bellucci, F. TiO2 Nanotubes on Ti Dental Implant. Part 2: EIS Characterization in Hank’s Solution. Metals 2017, 7, 220.

Show more citation formats Show less citations formats