Resonance Modes of Water Drops Pinned to a Vibrating Rectangular Post

Department of Physics and Astronomy, University of Padua, Via Marzolo 8, 35131 Padua, Italy
*
Author to whom correspondence should be addressed.
Micromachines 2024, 15(5), 634; https://doi.org/10.3390/mi15050634
Submission received: 7 April 2024 / Revised: 30 April 2024 / Accepted: 7 May 2024 / Published: 9 May 2024
(This article belongs to the Section A:Physics)

Abstract

:
We studied the effects of vertical vibrations on a water drop that was pinned to the sharp edges of a rectangular post. By varying the frequency and amplitude of the vertical displacement, distinct resonance peaks were observed using a simple optical technique. The vibrational spectra of the first two modes exhibited two closely spaced peaks, which corresponded to standing waves that exist along the major and minor contour lengths of the drops. The values of the resonance frequencies can be explained rather well by a simple model, which was originally proposed for axially symmetric drops.

1. Introduction

The wetting of a surface by a liquid is an everyday phenomenon that depends on both surface chemistry and surface morphology [1]. The presence of surface microstructures can enhance or inhibit the inhomogeneous distribution of a liquid in certain directions [2,3,4,5], giving rise to anisotropic droplet shapes [6] and interfacial instabilities [7]. In this case, anisotropy is due to the pinning of the contact line to the sharp edges of the asperities. Anisotropic wetting behavior is exhibited by many natural and synthetic surfaces. For example, the surfaces of many plants and animals are patterned by linear microstructures that can guide the motion of water droplets in well-defined directions [8]. Inspired by this rich phenomenology, many studies of anisotropic wetting have been conducted using biomimetic surfaces [9,10,11,12,13,14]. Particular attention has been devoted to the evolution of the shape of a liquid drop confined to the upper face of a rectangular post as its volume Ω increases. It is found that for small Ω, the liquid assumes a shape with a uniform cross section, while for large Ω, the liquid shows a central bulge [15]. Increasing the volume of the water drop leads to a morphological transition between the two shapes, which is observed for different geometries of the post [16,17,18,19].
The morphology transition from a flat channel into a localized bulge can also be induced by vertical vibrations of suitable amplitude [20]. Vibrations have been successfully used to actuate drops on surfaces regardless of the liquid properties [21,22,23], even against the action of gravity [24,25]. Vibrations can also induce the excitation of normal modes of the droplet, which can be used as a tool to measure the surface tension and viscosity of small droplets [26,27] or to micro-nebulize a liquid sample for biochemical analysis [28].
In general, the determination of the normal modes of a drop subject to vertical vibrations is studied in the two opposite limits of a fixed contact line and of a freely moving contact line: the former modes occur at a low amplitude of vibrations, whereas the latter modes appear above a threshold amplitude [29]. In the case of vibrated drops deposited on a homogeneous surface, axisymmetric surface waves of discrete frequencies are observed [30]. The different modes are stationary surface waves that exhibit a complicated three-dimensional wave pattern. Extensive numerical simulations are required to address the problem with gravity [31], and no analytical expressions are available to determine the resonance spectrum. To simplify the problem, Noblin et al. [30] considered the waves as one dimensional. In general, the drop contour can present m nodes ( m = 2 ,   3 ,   4 ), that is, characteristic points that do not move during periodic vibrations. The mean distance between two consecutive nodes along the drop contour is the corresponding pseudo wavelength λ m . If the drop contact line is fixed, one obtains the geometric relation m 1 λ m / 2 = l , where l represents the length of the drop contour at equilibrium [30]. In other words, these authors suggested that the resonant vibrational states of drops with pinned contact lines could be described by assuming that an integer number n = m 1 of half vibrational wavelengths fits along the contour length of the drops, where n = 1 ,   2 ,   3 can be identified as the mode number [32]. Examples of the drop shapes expected for the lowest frequency modes are shown in Figure 1a–d. The n = 1 mode implies a volume change, and is then not allowed for an incompressible liquid. The mode n = 2 is the lowest vibration mode that conserves volume for sessile drops when the contact line remains pinned and can be excited by a lateral vibration due to the substrate (“rocking” motion) [33]. The remaining panels represent the first two frequency modes (n = 3 and n = 4) that can be excited by vertical vibrations.
The pseudo wave vector values q n Ω , which correspond to the mode of order n and to a drop of a given volume Ω , can be calculated from
q n Ω = 2 π λ n = π n l
The general dispersion relation between the frequency f and the wave vector q of 1D capillary-gravity waves on a liquid bath of depth h assumed to be less than the capillary length of the liquid ( l c a p = γ / ϱ g ~ 2.7 mm for water) is given by [34]:
f 2 = 1 4 π 2 g q + γ ϱ q 3 tanh q h
where γ is the surface tension and ϱ is the mass density of the liquid, respectively, and g is the acceleration due to gravity. In their analysis, Noblin et al. [30] assumed for the wave vector the approximate Equation (1) and for h, the mean height of the drop profile h ¯ defined by
h ¯ = Ω Σ
where Σ is the wet area, that is, the area of the surface that is in contact with the drop. In other words, the resonance frequencies of the various normal modes can be determined by the following equation:
f n 2 = 1 4 π 2 g q n + γ ϱ q n 3 tanh q n h ¯
Despite its simplicity, this analysis was found to describe the experimental data rather well in the case of axially symmetric sessile drops of different volumes [30]. It was also successful in describing the dependence of the resonance frequency on the viscosity and contact angle of the drop [35,36]. If the drops are instead elongated along one direction, the vibrational spectra exhibit pairs of two nearby peaks. An extension of the model summarized by Equation (3) explains this observation as the result of the splitting of the fundamental vibration mode caused by the anisotropic wetting of the drop: the two closely spaced vibrational frequencies correspond to standing wave states that exist along the profile lengths related to the major and minor drop axes of the ellipsoidal drop [32].
In this work, we extend these studies to liquid drops, whose contact line is rectangular rather than circular or elliptical. The contact line was pinned to the sharp edges of a rectangular post that underwent vertical oscillations. Distinct resonance peaks were observed, which corresponded to the excitation of normal modes along the drop contour. Their values were accounted for rather well by a simple model, which was originally proposed for spherically symmetric drops [30]. The rest of this paper is organized as follows. Section 2 briefly describes the materials and experimental setups; we then present the measured resonance spectra and discuss the results in terms of the model of Noblin et al. [30].

2. Materials and Methods

2.1. Optofluidic Setup

The patterned sample was attached to the shaft of an electromagnetic shaker that could vibrate vertically, as shown in the schematic diagram in Figure 1e. The accessible frequency range was from 10 Hz to 10 kHz with a maximum vibrating amplitude A = 2.5 mm. An infrared photodetector (PD) was used to measure A in real-time with an estimated resolution close to 2 μm. This was calibrated by optically measuring the net displacement of the shaft. The shaker amplitude A decreases with the vibrating frequency f. Using a custom-made feedback circuit, it is also possible to sweep f while maintaining A constant over a frequency interval of approximately 500 Hz.
A liquid drop can be produced on the upper face of the rectangular post by connecting the central hole to a thin tube attached to a syringe pump (Harvard Apparatus, Holliston, MA, USA). A flow meter (Fluigent, Le Kremlin-bicêtre, France) was used to measure the drop volume Ω . The time evolution of the drop contour was recorded with a custom-made apparatus. Two LED sources (Phlox) could back-illuminate the drop from the two sides of the rectangular post. The drop contour was simultaneously viewed from the two orthogonal sides of the post with two high-resolution CCD cameras (Manta G-146B, Allied Vision Technologies, Stadtroda, Germany) equipped with 2× telecentric objectives (VS-TC2-110, VS Technology, Tokyo, Japan), as shown in Figure 1f. To neglect evaporation, the sample was enclosed in a transparent box with a controlled degree of humidity. Considering that a full acquisition run takes less than 5 min, we can confidently state that Ω remained constant during the measurement of the vibrational spectra. Further details on the setup have been reported elsewhere [20].

2.2. Fabrication of the Rectangular Posts

Special care was taken to fabricate rectangular posts with sharp edges and corners. Individual posts in polydimethilsiloxane (PDMS) with a rectangular cross section were manufactured by a double replica molding technique, following a similar procedure used in a previous study [15]. To ensure the planarity of the posts, micro-milling (Minitech Machinery Co., Norcross, GA, USA) was used for mold microfabrication, starting from a polished brass plate (see Figure 2a). The characteristic dimensions of the posts were: height h = 100 μm, length L = 2500 μm and width W = 500 μm; the corresponding aspect ratio is then l = L / W = 5 . The upper face of the PDMS post presented a through hole with a diameter ~150 μm in the center that allowed for the infusion of water on its surface (see Figure 2b–d).
Once produced, the PDMS posts are hydrophobic, with a contact angle θ0 = 110° for water. To exclusively modify the wettability of their upper faces, these were coated with a thin gold layer with a thickness of ~200 nm deposited by magneto-sputtering. Before the sputtering process, the vertical walls were covered with a UV curable optical adhesive, NOA 61, preserving them from gold deposition, as shown in Figure 2b. Right before each measurement, the gold surface was exposed to oxygen plasma (Diener electronic, Ebhausen, Germany), and then the NOA 61 coating was peeled off (see Figure 2c,d). As a result, the contact angle on the upper face was reduced to θ0~15° and remained stable for a couple of hours, while the vertical walls were hydrophobic. In this way, water was confined only at the top of the post. The volume of the water drop pinned to the edge of the post was controlled with a syringe pump. Figure 2e shows the individual post ready to be mounted on the shaker and connected to the syringe pump through a polyethylene tube.

3. Results and Discussion

The graph in Figure 3a displays the maximum height H of the drop, measured from the upper face of the post, as a function of Ω . The inset displays the two orthogonal views of the drop corresponding to the red circle indicated on the graph. As expected, H continuously increased with Ω because the aspect ratio of the post was much smaller than the critical value l c r i t = 16, above which a discontinuous transition from a filament to the bulge state is predicted [15]. Furthermore, the use of a short post, that is, l < l c r i t , guarantees that no morphology transition from the filament to the bulge state can be induced by applying vertical vibrations to the substrate [20]. Consequently, vibrating the post can only excite the normal modes of the drop pinned to its rectangular perimeter.
To study the normal modes of the water drop, we applied vertical sinusoidal vibrations to the sample, sweeping the frequency range at a constant amplitude. At each frequency f , we measured the vertical displacement of the vibrating drop contour along the symmetry axis by analyzing the shaded areas of the video frames, obtained by setting an acquisition time period for the video camera at least 10 times longer than the vibration period, so that each frame shows the superposition of many instantaneous profiles integrated over an extended time interval. The quantity Δ represents the height of the shaded area with respect to the equilibrium (black) contour, as indicated in Figure 3b, and was extracted from the individual frames using the free software ImageJ 1.54f. To ensure that the value of Δ was detectable at frequencies far from the resonance peaks, for each mode n, the frequency scan was performed with a different constant amplitude A f n . The schematic diagram of Figure 3c highlights the corresponding static and instantaneous profiles, together with the indication of the nodes and the pseudo wavelength λ n . Before each measurement, the drop was prepared by infusing water onto the rectangular post until a maximum height H = 1 mm was reached.
The graph in Figure 4a reports the resonance curves with the lowest frequencies. They refer to the same water volume Ω = 1.17 μL, which corresponds to a maximum height of the static drop H = 1 mm.
The y-axis reports the vertical displacement normalized to the vertical acceleration according to: Δ n o r m = Δ a r e f f n / a f n , where a f n = 2 π f n 2 A f n is the acceleration corresponding to the resonance mode n and a r e f f n = 2 π f n 2 A r e f is the reference acceleration corresponding to the amplitude A r e f , used to scan the lowest frequency mode. Each curve was identified with a label that reported the mode number n followed by the letter L (T), which stands for longitudinal (transversal). As expected, the vibrational spectra of the first two modes exhibited two closely spaced peaks, which corresponded to standing waves that exist along the major and minor contour lengths of the drops [32]. This interpretation was confirmed by the analysis of the two corresponding orthogonal views, which are shown in the (b) panels (see also Supplementary Video S1 taken at about 20 fps and with an exposure time of about 20 ms). In the different snapshots, the nodes are highlighted with empty circles. The modes were then labelled T (L) if the nodes appeared in the transversal (longitudinal) views. Only odd modes were observed because the drops underwent vertical vibrations. Instead, even modes (“rocking” modes) could only be excited by lateral vibrations.
The experimental resonance values are listed in Table 1 and can be compared with the predictions of the simple model expressed by Equation (4). The lengths of the transversal and longitudinal contours of the drops were l T = 3.16 ± 0.05 mm and l L = 3.60 ± 0.05 mm, respectively, as deduced by image processing of the two static contours. Similarly, the average height h ¯ was calculated by numerical integration of the two static images. More precisely, the average heights h ¯ T and h ¯ L of the transversal and longitudinal cross-section of the drop, respectively, calculated from the images as
h ¯ T , L = 1 Σ T , L 0 H z ρ T , L z d z
where Σ T , L is the area of the cross-section and ρ T , L z is the width of the cross-section at the height z. The values obtained were h ¯ T = 0.48 ± 0.02 mm and h ¯ L = 0.37 ± 0.02 mm. In previous studies, the average height was calculated analytically assuming a semicircular contour [36,37,38].
The resonance frequencies for the different modes can then be derived from Equation (4), and the calculated values are listed in Table 1. The good agreement with the corresponding experimental values confirms that the simple model of Noblin et al. [30] also provides an accurate description in the extreme case of elongated drops that present a rectangular contact line. For a more precise estimate, the common procedure is to introduce a geometric factor α. This empirical factor is usually determined by studying the evolution of the resonance frequency with the drop volume [37,38]. The resonance frequency of a vibrating mode decreases with the volume of the drop volume according to f = α / Ω , as it can be easily derived from Equations (1) and (4) under the assumption that the length of the drop contour scales as l ~ Ω 3 (see e.g., Ref. [38]). By measuring the variation of f vs. Ω , the geometric factor can be empirically determined. However, this requires that the overall shape of the drop including contact angles do not vary with volume. This is straightforward on a flat, homogeneous surface where the contact line is a circle, and the contact angle does not vary with Ω and Ω 3 < l c a p (see e.g., Ref. [38]) or for a surface patterned with narrow linear stripes where the contact line is an ellipse and the contact angles along the two main axes do not vary with Ω (see e.g., Ref. [32]). In our case, maintaining a rectangular contact line requires the fabrication of a series of rectangular posts with hydrophobic vertical faces and hydrophilic upper faces, all of which have the same aspect ratio but different sizes. This can be undertaken, but it requires much more effort. The analysis we present suggests that this calibration is not necessary, and that it is possible to evaluate the resonance modes once the drop geometry is known.

4. Conclusions

We reported on the detection of the first resonance modes of confined water drops that undergo vertical vibrations. The drop contact line was pinned to the contour of a rectangular post fabricated by double replica molding of a master obtained by micro-milling. The vibrational spectra of the first two modes exhibited two closely spaced peaks, which a direct visual analysis carried out with video cameras associated with the excitation of standing waves along the major and minor contour lengths of the drops. The values of the resonance frequencies could be explained rather well by a simple model, which was originally proposed for axially symmetric drops. Our results thus also extend the applicability of this model to highly anisotropic drops.

Supplementary Materials

The following are available online at https://www.mdpi.com/article/10.3390/mi15050634/s1, Video S1: Normal modes of vibrating drops.

Author Contributions

Conceptualization, P.S. and G.M.; Methodology, P.S., D.F., M.P. and G.M.; Data curation, P.S.; Writing—original draft preparation, P.S. and G.M.; Funding acquisition, D.F., M.P. and G.M. All authors have read and agreed to the published version of the manuscript.

Funding

This research was funded by the University of Padova through the BIRD grant 2021 (BiodivSeq). We acknowledge financial support under the National Recovery and Resilience Plan (NRRP), Mission 4, Component 2, Investment 1.1, Call No. 104 (2 February 2022) and No. 1409 (14 September 2022) by the Italian Ministry of University and Research (MUR), funded by the European Union—NextGenerationEU—for the Projects OCEAN (CUP C53D23000790006; No. 2022YYLSJ2) and EXTREME (CUP G53D23007030001; No. P2022J2ZC2), adopted by the Italian Ministry of University and Research (MUR).

Data Availability Statement

Data are contained within the article or Supplementary Materials.

Acknowledgments

The authors are particularly grateful to Giorgio Delfitto for his valuable technical assistance, Boris Kalinic for assistance in the sputtering process, and Tommaso Furieri for support in the data acquisition. The authors thank Marco Bazzan and Andrea Moscatello for using the metallurgical microscope.

Conflicts of Interest

The authors declare that they have no conflict of interest.

References

  1. De Gennes, P.G.; Brochard-Wyart, F.; Quéré, D. Capillarity and Wetting Phenomena: Drops, Bubbles, Pearls, Waves; Springer: New York, NY, USA, 2004. [Google Scholar]
  2. Chu, K.H.; Xiao, R.; Wang, E.N. Uni-directional liquid spreading on asymmetric nanostructured surfaces. Nat. Mater. 2010, 9, 413–417. [Google Scholar] [CrossRef]
  3. Xia, D.Y.; Johnson, L.M.; López, G.P. Anisotropic wetting surfaces with one-dimesional and directional structures: Fabrication approaches, wetting properties and potential applications. Adv. Mater. 2012, 24, 1287–1302. [Google Scholar] [CrossRef]
  4. Semprebon, C.; Varagnolo, S.; Filippi, D.; Perlini, L.; Pierno, M.; Brinkmann, M.; Mistura, G. Deviation of sliding drops at a chemical step. Soft Matter 2016, 12, 8268–8273. [Google Scholar] [CrossRef]
  5. Cai, Z.X.; Chen, F.Z.; Tian, Y.L.; Zhang, D.W.; Lian, Z.X.; Cao, M.Y. Programmable droplet transport on multi-bioinspired slippery surface with tridirectionally anisotropic wettability. Chem. Eng. J. 2022, 449, 137831. [Google Scholar] [CrossRef]
  6. Hancock, M.J.; Sekeroglu, K.; Demirel, M.C. Bioinspired directional surfaces for adhesion, wetting, and transport. Adv. Funct. Mater. 2012, 22, 2223–2234. [Google Scholar] [CrossRef]
  7. Gau, H.; Herminghaus, S.; Lenz, P.; Lipowsky, R. Liquid morphologies on structured surfaces: From microchannels to microchips. Science 1999, 283, 46–49. [Google Scholar] [CrossRef]
  8. Liu, K.S.; Yao, X.; Jiang, L. Recent developments in bio-inspired special wettability. Chem. Soc. Rev. 2010, 39, 3240–3255. [Google Scholar] [CrossRef]
  9. Chen, Y.; He, B.; Lee, J.H.; Patankar, N.A. Anisotropy in the wetting of rough surfaces. J. Colloid Interface Sci. 2005, 281, 458–464. [Google Scholar] [CrossRef]
  10. Kusumaatmaja, H.; Leopoldes, J.; Dupuis, A.; Yeomans, J.M. Drop dynamics on chemically patterned surfaces. Europhys. Lett. 2006, 73, 740–746. [Google Scholar] [CrossRef]
  11. Chung, J.Y.; Youngblood, J.P.; Stafford, C.M. Anisotropic wetting on tunable micro-wrinkled surfaces. Soft Matter 2007, 3, 1163–1169. [Google Scholar] [CrossRef]
  12. Xia, D.Y.; Brueck, S.R.J. Strongly anisotropic wetting on one-dimensional nanopatterned surfaces. Nano Lett. 2008, 8, 2819–2824. [Google Scholar] [CrossRef] [PubMed]
  13. Semprebon, C.; Mistura, G.; Orlandini, E.; Bissacco, G.; Segato, A.; Yeomans, J.M. Anisotropy of water droplets on single rectangular posts. Langmuir 2009, 25, 5619–5625. [Google Scholar] [CrossRef]
  14. Semprebon, C.; Herrmann, C.; Liu, B.Y.; Seemann, R.; Brinkmann, M. Shape evolution of droplets growing on linear microgrooves. Langmuir 2018, 34, 10498–10511. [Google Scholar] [CrossRef]
  15. Ferraro, D.; Semprebon, C.; Toth, T.; Locatelli, E.; Pierno, M.; Mistura, G.; Brinkmann, M. Morphological transitions of droplets wetting rectangular domains. Langmuir 2012, 28, 13919–13923. [Google Scholar] [CrossRef] [PubMed]
  16. Schaefle, C.; Brinkmann, M.; Bechinger, C.; Leiderer, P.; Lipowsky, R. Morphological wetting transitions at ring-shaped surface domains. Langmuir 2010, 26, 11878–11885. [Google Scholar] [CrossRef]
  17. Dokowicz, M.; Nowicki, W. Morphological transitions of droplets wetting a series of triangular grooves. Langmuir 2016, 32, 7259–7264. [Google Scholar] [CrossRef]
  18. Sauret, A.; Bick, A.D.; Duprat, C.; Stone, H.A. Wetting of crossed fibers: Multiple steady states and symmetry breaking. Europhys. Lett. 2014, 105, 56006. [Google Scholar] [CrossRef]
  19. Ma, B.J.; Shan, L.; Dogruoz, B.; Agonafer, D. Evolution of microdroplet morphology confined on asymmetric micropillar structures. Langmuir 2019, 35, 12264–12275. [Google Scholar] [CrossRef]
  20. Sartori, P.; Bonato, L.; Delfitto, G.; Pierno, M.; Mistura, G.; Semprebon, C.; Brinkmann, M. Morphological transitions of water channels induced by vertical vibrations. Langmuir 2018, 34, 12882–12888. [Google Scholar] [CrossRef]
  21. Dong, L.; Chaudhury, A.; Chaudhury, M.K. Lateral vibration of a water drop and its motion on a vibrating surface. Eur. Phys. J. E 2006, 21, 231–242. [Google Scholar] [CrossRef]
  22. Daniel, S.; Chaudhury, M.K. Rectified motion of liquid drops on gradient surfaces induced by vibration. Langmuir 2002, 18, 3404–3407. [Google Scholar] [CrossRef]
  23. Noblin, X.; Kofman, R.; Celestini, F. Ratchetlike motion of a shaken drop. Phys. Rev. Lett. 2009, 102, 194504. [Google Scholar] [CrossRef] [PubMed]
  24. Brunet, P.; Eggers, J.; Deegan, R.D. Vibration-induced climbing of drops. Phys. Rev. Lett. 2007, 99, 144501. [Google Scholar] [CrossRef]
  25. Sartori, P.; Guglielmin, E.; Ferraro, D.; Filippi, D.; Zaltron, A.; Pierno, M.; Mistura, G. Motion of Newtonian drops deposited on liquid-impregnated surfaces induced by vertical vibrations. J. Fluid Mech. 2019, 876, R4. [Google Scholar] [CrossRef]
  26. Nguyen, T.V.; Nguyen, M.D.; Takahashi, H.; Matsumoto, K.; Shimoyama, I. Viscosity measurement based on the tapping-induced free vibration of sessile droplets using MEMS-based piezoresistive cantilevers. Lab Chip 2015, 15, 3670–3676. [Google Scholar] [CrossRef]
  27. Harrold, V.C.; Sharp, J.S. Optovibrometry: Tracking changes in the surface tension and viscosity of multicomponent droplets in real-time. Soft Matter 2016, 12, 8790–8797. [Google Scholar] [CrossRef]
  28. Pan, C.T.; Shiea, J.; Shen, S.C. Fabrication of an integrated piezo-electric micro-nebulizer for biochemical sample analysis. J. Micromech. Microeng. 2007, 17, 659–669. [Google Scholar] [CrossRef]
  29. Noblin, X.; Buguin, A.; Brochard-Wyart, F. Vibrations of sessile drops. Eur. Phys. J. Special Topics 2009, 166, 7–10. [Google Scholar] [CrossRef]
  30. Noblin, X.; Buguin, A.; Brochard-Wyart, F. Vibrated sessile drops: Transition between pinned and mobile contact line oscillations. Eur. Phys. J. E 2004, 14, 395–404. [Google Scholar] [CrossRef] [PubMed]
  31. Wilkes, E.D.; Basaran, O.A. Forced oscillations of pendant (sessile) drops. Phys. Fluids 1997, 9, 1512–1528. [Google Scholar] [CrossRef]
  32. Temperton, R.H.; Sharp, J.S. Vibrational modes of elongated sessile liquid droplets. Langmuir 2013, 29, 4737–4742. [Google Scholar] [CrossRef] [PubMed]
  33. Daniel, S.; Chaudhury, M.K.; de Gennes, P.G. Vibration-actuated drop motion on surfaces for batch microfluidic processes. Langmuir 2005, 21, 4240–4248. [Google Scholar] [CrossRef] [PubMed]
  34. Landau, L.D.; Lifshitz, E.M. Fluid Mechanics, 2nd ed.; Pergamon Press: Oxford, UK, 1987. [Google Scholar]
  35. Mettu, S.; Chaudhury, M.K. Vibration spectroscopy of a sessile drop and its contact line. Langmuir 2012, 28, 14100–14106. [Google Scholar] [CrossRef]
  36. Sharp, J.S. Resonant properties of sessile droplets; contact angle dependence of the resonant frequency and width in glycerol/water mixtures. Soft Matter 2012, 8, 399–407. [Google Scholar] [CrossRef]
  37. Sharp, J.S.; Farmer, D.J.; Kelly, J. Contact angle dependence of the resonant frequency of sessile water droplets. Langmuir 2011, 27, 9367–9371. [Google Scholar] [CrossRef]
  38. Costalonga, M.; Brunet, P. Directional motion of vibrated sessile drops: A quantitative study. Phys. Rev. Fluids 2020, 5, 023601. [Google Scholar] [CrossRef]
Figure 1. Schematic representation of the drop profiles for the modes n = 1 (a), n = 2 (b), n = 3 (c), and n = 5 (d). The dashed lines indicate the static contour. The nodes are highlighted with red circles. (e) Sketch of the rectangular post attached to the shaft of the shaker. The vertical displacement of the shaft was measured with the infrared photodetector (IR PD). (f) Geometry of the rectangular post. Water was infused into the drop through the central hole. The post top face in contact with water was covered with a hydrophilic gold layer, whereas the vertical walls were hydrophobic.
Figure 1. Schematic representation of the drop profiles for the modes n = 1 (a), n = 2 (b), n = 3 (c), and n = 5 (d). The dashed lines indicate the static contour. The nodes are highlighted with red circles. (e) Sketch of the rectangular post attached to the shaft of the shaker. The vertical displacement of the shaft was measured with the infrared photodetector (IR PD). (f) Geometry of the rectangular post. Water was infused into the drop through the central hole. The post top face in contact with water was covered with a hydrophilic gold layer, whereas the vertical walls were hydrophobic.
Micromachines 15 00634 g001
Figure 2. (a) Brass master copy of the individual post produced by micro-milling, to be used as a mold. (b) Gold layer on the PDMS post with vertical walls protected by NOA 61 adhesive. (c,d) Post with NOA 61 peeled off; the thin tube for water infusion can be observed through transparent PDMS in (d). All scale bars, indicated in blue, correspond to 1 mm. (e) Overview of the PDMS post glued to a microscope glass slide.
Figure 2. (a) Brass master copy of the individual post produced by micro-milling, to be used as a mold. (b) Gold layer on the PDMS post with vertical walls protected by NOA 61 adhesive. (c,d) Post with NOA 61 peeled off; the thin tube for water infusion can be observed through transparent PDMS in (d). All scale bars, indicated in blue, correspond to 1 mm. (e) Overview of the PDMS post glued to a microscope glass slide.
Micromachines 15 00634 g002
Figure 3. (a) Growth of the maximum height of drop H as a function of the drop volume Ω . Indicative error bars are only reported for the first point. The inset shows the equilibrium longitudinal and transversal images of the water drop corresponding to the red circle indicated in the graph. The drop contour lengths are highlighted in the two cases. (b) Longitudinal view of the vibrating water drop. The vertical peak-to-peak amplitude Δ of the drop contour is also indicated. (c) Schematic representation of the corresponding longitudinal mode: the nodes are indicated by blue circles. Dashed lines denote the static and instantaneous drop contours. The contour length between two consecutive nodes is the pseudo wavelength λ n .
Figure 3. (a) Growth of the maximum height of drop H as a function of the drop volume Ω . Indicative error bars are only reported for the first point. The inset shows the equilibrium longitudinal and transversal images of the water drop corresponding to the red circle indicated in the graph. The drop contour lengths are highlighted in the two cases. (b) Longitudinal view of the vibrating water drop. The vertical peak-to-peak amplitude Δ of the drop contour is also indicated. (c) Schematic representation of the corresponding longitudinal mode: the nodes are indicated by blue circles. Dashed lines denote the static and instantaneous drop contours. The contour length between two consecutive nodes is the pseudo wavelength λ n .
Micromachines 15 00634 g003
Figure 4. (a) Resonance peaks of water drops of volume Ω = 1.17 μL deposited on the upper face of a post that undergoes vertical oscillations of constant amplitude. The vertical axis refers to the normalized vertical displacement Δ n o r m . The label beside each peak identifies the resonance mode. (b) Transversal (T) and longitudinal (L) normal modes observed from front and side views. Oscillation nodes are highlighted by colored circles. The colors correspond to the data in panel (a).
Figure 4. (a) Resonance peaks of water drops of volume Ω = 1.17 μL deposited on the upper face of a post that undergoes vertical oscillations of constant amplitude. The vertical axis refers to the normalized vertical displacement Δ n o r m . The label beside each peak identifies the resonance mode. (b) Transversal (T) and longitudinal (L) normal modes observed from front and side views. Oscillation nodes are highlighted by colored circles. The colors correspond to the data in panel (a).
Micromachines 15 00634 g004
Table 1. Resonance frequencies for transversal and longitudinal normal modes.
Table 1. Resonance frequencies for transversal and longitudinal normal modes.
Mode Number
N
Experimental
T Mode Frequency
fT (Hz)
Theoretical
T Mode Frequency
fT (Hz)
Experimental
L Mode Frequency
fL (Hz)
Theoretical
L Mode Frequency
fL (Hz)
3200 ± 5208 ± 6135 ± 5156 ± 4
5465 ± 5469 ± 13350 ± 5374 ± 9
7830 ± 20783 ± 22
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Sartori, P.; Ferraro, D.; Pierno, M.; Mistura, G. Resonance Modes of Water Drops Pinned to a Vibrating Rectangular Post. Micromachines 2024, 15, 634. https://doi.org/10.3390/mi15050634

AMA Style

Sartori P, Ferraro D, Pierno M, Mistura G. Resonance Modes of Water Drops Pinned to a Vibrating Rectangular Post. Micromachines. 2024; 15(5):634. https://doi.org/10.3390/mi15050634

Chicago/Turabian Style

Sartori, Paolo, Davide Ferraro, Matteo Pierno, and Giampaolo Mistura. 2024. "Resonance Modes of Water Drops Pinned to a Vibrating Rectangular Post" Micromachines 15, no. 5: 634. https://doi.org/10.3390/mi15050634

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.