Next Article in Journal
Evaluation of Subsequent Heat Treatment Routes for Near-β Forged TA15 Ti-Alloy
Previous Article in Journal
Influence of Amphibian Antimicrobial Peptides and Short Lipopeptides on Bacterial Biofilms Formed on Contact Lenses
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks’ Simulated Body Fluid

1
High School Attached to Shandong Normal University, Jinan 250014, China
2
Key Laboratory of High Efficiency and Clean Mechanical Manufacture of MOE, School of Mechanical Engineering, Shandong University, Jinan 250061, China
3
Department of Mechanical Engineering, Michigan State University, Lansing, MI 48910, USA
*
Author to whom correspondence should be addressed.
Materials 2016, 9(11), 874; https://doi.org/10.3390/ma9110874
Submission received: 22 August 2016 / Revised: 13 October 2016 / Accepted: 23 October 2016 / Published: 26 October 2016
(This article belongs to the Section Biomaterials)

Abstract

:
Titanium and its alloys have been widely used as implant materials due to their excellent mechanical property and biocompatibility. In the present study, the effect of glucose concentration on corrosion behavior of pure titanium TA2 in Hanks’ simulated body fluid is investigated by the electrochemical impedance spectrum (EIS) and potentiodynamic polarization methods. The range of glucose concentrations investigated in this research includes 5 mmol/L (limosis for healthy people), 7 mmol/L (after diet for healthy people), 10 mmol/L (limosis for hyperglycemia patient), and 12 mmol/L (after diet for hyperglycemia patient), as well as, 15 mmol/L and 20 mmol/L, which represent different body fluid environments. The results indicate that the pure titanium TA2 demonstrates the best corrosion resistance when the glucose concentration is less than 10 mmol/L, which shows that the pure titanium TA2 as implant material can play an effective role in the body fluids with normal and slight high glucose concentrations. Comparatively, the corrosion for the pure titanium implant is more probable when the glucose concentration is over 10 mmol/L due to the premature penetration through passive film on the material surface. Corrosion defects of pitting and crevice exist on the corroded surface, and the depth of corrosion is limited to three microns with a low corrosion rate. The oxidation film on the surface of pure titanium TA2 has a protective effect on the corrosion behavior of the implant inner material. The corrosion behavior of pure titanium TA2 will happen easily once the passive film has been penetrated through. The corrosion rate for TA2 implant will accelerate quickly and a pure titanium implant cannot be used.

1. Introduction

Titanium and its alloys have excellent properties such as high specific strength (i.e., strength-to-weight ratio, etc.), high toughness, high corrosion resistance and excellent biocompatibility [1,2,3]. They have been widely used as implant materials in such occasions as dental implant [4], tooth orthopedic line [5], artificial joint [6], bone trauma product [7], interventional cardiovascular stent [8], etc. The titanium alloy Ti6Al4V has once been applied as the main implant material in the biomedical field, due to its enhanced mechanical properties with the addition of such alloy elements as aluminum and vanadium. However, the dissolution of poisonous elements has been noticed for implants made of Ti6Al4V recently, which leads to some negative effects related to human physiological health [9,10]. Comparatively, the application of pure titanium implants is much safer which can reduce the secondary hazards of implant materials on human physiological health [11].
Pure titanium has very high chemical activity, so it is apt to be passivated by oxygen within the atmosphere of air or oxygen-rich solutions. Pure titanium is usually regarded as self-passivating metal. There is a layer of compact oxidation film formed on the material surface of pure titanium after self-passivation and its thickness ranges from several nanometers to tens of nanometers. Consequently, the pure titanium owns excellent corrosion resistance. Previous research has revealed that the oxidation film on pure titanium is in a state of dynamic balance between dissolution and repair (i.e., second passivation) processes within solutions [12]. If the dynamic balance state is destroyed by some specific solution components or other physical and chemical factors, the corrosion degree of pure titanium may be aggravated dramatically.
Surface corrosion is the main problem that the metal implant materials meet in clinical application. The main type of corrosion for biomedical metals is localized corrosion [13]. It means that if one localized area is corroded, the rest area of the surface is nearly undamaged. The existence of microorganism or some specific chemical components may not destroy the implant surface directly, but they can create the necessary conditions for electrochemical corrosion leading to severe damage on implant materials.
Over one thousand tons of titanium and titanium alloys are used as implant materials in the world every year [14]. Although the corrosion resistance of these kinds of materials is much better that the other metals, their corrosion problem especially for receptors with special corporeity, has still attracted much attention gradually in recent years. For example, precious research [15,16] has found severe health problems caused by the bone anchored hearing aid made of titanium alloys. They found that there were titanium particles spreading around the implant hearing aid within the soft tissue of receptors, which leaded to the localized inflammation. The titanium particles were not residual fragments produced during surgery process. They were also not caused by wear because ears are not movable organ. The main reason leading to the formation of titanium particles was the corrosion of implant material surface, which subsequently caused the fragments separation from the implant surface. Rogers et al. [17] carried out research to determine whether in vitro studies would detect differences in the cellular response to wear particles of titanium alloy and pure titanium commonly used in the manufacture of joint replacement prostheses. They researched the particles with the order of 1 micron in diameter representative of those found adjacent to failed prostheses. Exposure of human monocytes to Ti6Al4V at concentrations of 4 × 107 particles/mL produced a mean prostaglandin E2 release of 2627.6 pM, while commercially-pure titanium particles induced a release of only 347.8 pM. In addition, Ti6Al4V stimulated significantly more release of the other cell mediators, interleukin-1, tumor necrosis factor and interleukin-6. Their results showed that the pure titanium is recommended to be used as implant material instead of titanium alloys in order to avoid negative effects on human health.
This paper aims to research the corrosion behavior of pure titanium TA2 used as implant material within the atmosphere of Hanks’ simulated body fluid (SBF). In addition, the body fluids of hyperglycemia patients with special corporeity are selected as the research objective. The difference of corrosion behavior of implant material TA2 used in the simulated body fluids of healthy people and hyperglycemia patients will be compared. The electrochemistry method is adopted to investigate the corrosion behavior of TA2 implants within different Hanks’ SBFs. The polarization curve and corrosion potential variation are researched to assess the corrosion resistance of the implant material. The research will reveal the effect of blood glucose concentration on the corrosion behavior of TA2 implant material, which can help to lay a solid theoretical foundation for improvement of the corrosion resistance of pure titanium implants. The research results can also help to instruct the clinical application of pure titanium implants in surgery.

2. Material and Experimental Procedure

2.1. Experimental Material and Electrode Preparation

Pure titanium TA2 was selected as the research objective which has excellent mechanical properties and good corrosion resistance. The chemical compositions (wt.%) of TA2 include Fe ≤ 0.30, C ≤ 0.10, N ≤ 0.05, H ≤ 0.015, O ≤ 0.25, and the rest is Ti. Pure titanium TA2 used in this research was purchased from Baoji Titanium Industry Company Limited (Baoji, China). The cylindrical specimens with dimensions of Φ6 mm × 2 mm were prepared through the procedures of wire electrical discharge machining and polishing.
The back surfaces of specimens were connected with copper interconnects through welding technique or conductive adhesive. After detection of connecting reliability with multimeter, the specimens were packaged with epoxy resin. E-51 epoxy resin was used as the casting material. Methylhexahydrophthalic anhydride (M-HHPA), N,N-Dimethyl benzyl amine (BDMA) and fumed silica (SiO2) were selected as the curing agent, the curing accelerator and the padding, respectively. The above materials were mixed evenly with the weight ratio (wt.%) of E-51:M-HHPA:SiO2:BDMA = 400:240:150:1. Then the mixed material was degassed in the vacuum drying oven under 40 °C, after that the mixed material was filled into a specifically designed die to make the electrodes. At last, the casting epoxy resin TA2 electrodes were placed into the vacuum drying oven for solidification. The solidification process was carried out under 80 °C for 2 h combined with 120 °C for 4 h. After the procedure of solidification, the epoxy resin TA2 electrodes were air-cooled to room temperature.
The TA2 electrodes were grinded with raw emery paper to make sure that the front surfaces of electrodes were uncovering. Then they were further grinded using abrasive papers with particle size of 400#, 800#, 1200# and 2000#. The grinded electrodes were polished with lint and ultrasonic cleaned with acetone and absolute ethyl alcohol sequentially. The impurities including grease on the specimen surfaces were wiped off and then the specimen surfaces were dried with nitrogen. The ultimate surface roughness Ra of the specimens prepared for the electrochemical test is 0.2 μm.

2.2. Experimental Setup of Electrochemical Corrosion

Table 1 shows the ranges of blood glucose concentration for healthy people and hyperglycemia patient. Because the body fluid environment is complex and changeful, the blood glucose concentration varies at different time or before and after the diet, which will directly affect the corrosion behavior of titanium implants. The variations of corrosion behavior for titanium implants determine their service lives and even do harm to the body health and life safety of patients. Based on the information in Table 1, the range of blood glucose concentration investigated in this research is then determined for healthy people and hyperglycemia patient, The background of diets for the variation of glucose concentrations in Table 1 is daily normal diets [18].
The experiments of electrochemical corrosion for TA2 were carried out on CHI 604A electrochemical workstation produced by Shanghai Chenhua Instrument Co., Ltd. (Shanghai, China). The other experimental instruments used are introduced in Table 2. The electrolytic tank of three electrodes system was adopted in this research, during which the TA2 electrode was the working electrode. The saturated calomel electrode and platinum gauze electrode with the cross-sectional area of 1 cm2 were selected as the reference electrode and auxiliary electrode, respectively.
The etchant solutions included analytical reagents and Hanks’ SBFs. The Hanks’ SBFs were prepared using deionized water. The components of SBFs include NaCl 8 g + KCl 0.4 g + CaCl2 0.14 g + NaHCO3 0.35 g + MgCl2·H2O 0.1 g + MgSO4·H2O 0.06 g + KH2PO4 0.06 g + Na2HPO4·H2O 0.06 g. All these solutes were dissolved in deionized water and diluted to 1000 mL, after that the Hanks’ SBFs were prepared well. There were six groups of Hanks’ SBFs in total prepared for the experiments, and there were five specimens tested in every group of Hanks’ SBFs. The glucose C6H6O6 with weights of 0.9 g, 1.26 g, 1.8 g, 2.16 g, 2.7 g and 3.6 g per 1000 mL was added into the six groups of Hanks’ SBFs. Consequently, the SBFs with different glucose concentrations, 5 mmol/L (limosis for healthy people), 7 mmol/L (after diet for healthy people), 10 mmol/L (limosis for hyperglycemia patient), 12 mmol/L (after diet for hyperglycemia patient), 15 mmol/L and 20 mmol/L, respectively, were obtained. The analytic reagents used in the experiments are presented in Table 3.
The three electrodes, the working electrode, the reference electrode and the auxiliary electrode were immersed into different SBFs with varied glucose concentrations for 3000 s, which could then form the stable electrochemical systems and the open circuit potential (OCP) was measured.
The measurement of electrochemical impedance spectroscopy (EIS) was carried out under the condition of OCP. The frequency range of measurement was set as from 10–2 Hz to 105 Hz and the amplitude of sine altering current was set as 5 mV. The EIS data were analyzed using the software of Zsimp-win.
During measurement of the potentiodynamic polarization curve, the scanning range of the electric potential was set as ±200 mV with respect to the OCP, and the scanning speed was set as 10 mV/s. The Tafel curve was fitted base on the extrapolation method, through which the electrochemical corrosion parameters including the self-corrosion potential and the self-corrosion current were determined.

3. Results and Discussion

3.1. Measurement and Analysis of EIS

The results of EIS for TA2 under different glucose concentrations are shown in Figure 1 and Figure 2. It can be seen from Figure 1a that the Nyquist curves of TA2 under different glucose concentrations can be all regarded as one part of arcs. The Nyquist curves corresponding to low frequency area belong to arcs with large capacitive reactance as shown in Figure 1a, while those corresponding to high frequency area belong to arcs with small capacitive reactance as shown in Figure 1b. Thus, there are two time constants to be determined. When the frequency ranges from 0.01 Hz to 1 Hz, the polarization resistance of TA2 specimen exceeds 105 Ω·cm2 as shown in Figure 2a, and the phase angle approaches −60° as shown in Figure 2b.
The arc in Nyquist figure reflects the impedance magnitude during the electron transfer process on electrode surface. The bigger the arc in Nyquist figure is, the larger resistance for electron transfer will be. The larger resistance for electron transfer means that the capture and loss of electrons are difficult, i.e., the metal is difficult to be dissolved or corroded.
When the glucose concentration ranges from 10 mmol/L to 12 mmol/L, the reverse capacitive reactance arc occurs within the high frequency area in the EIC figure as shown in Figure 1b. The reason is that one layer of steady passivated film is formed on the specimen surface after a period of reaction time between the specimen and the Hanks’ SBF, which improves the corrosion resistance of TA2 specimen. The passivated layer equals to a shielding layer with large resistance and low capacitance. It isolates the further contact between the specimen inner material and the solution that protects the specimen inner material from being corroded. It can be seen that there are significant variations for the phase profiles in Figure 2b especially for the glucose concentratios of 15 mmol/L and 20 mmol/L. The reason is that the aggregation of glucose on the specimen surface increases with the increase of glucose concentration, which enhances the phenomenon of double-layer capacitor and induces the double peak phenomenon. Actually, the tendency for the formation of this phenomenon has been presented under the glucose concentration of 10 mmol/L.
From the Bode phase angle plot (Figure 2b), at least two time constants are required to fit the EIS results. The oxidation film formed on TA2 specimen consists of compact inner oxidation layer and loosened outer oxidation layer. The inner and out oxidation layers have different electrochemical kinetics characteristics. Figure 3 presents the equivalent circuit diagram as Rs(Rp1Ce)(Rp2Cd) for TA2 within the Hanks’ SBF, where Rs denotes the solution resistance of the electrode system. Rp1 and Rp2 denote the values of resistance for the inner oxidation layer and the outer oxidation layer, respectively; and Ce and Cd denote the values of capacitance for the inner oxidation layer and the outer oxidation layer, respectively.
According to the equivalent circuit diagram in Figure 3, the EIS data were fitted using the software of Zsimp-win. Then the dependence of electrochemical corrosion properties of TA2 electrode on the glucose concentration can be determined as shown in Table 4. The constant phase elements (CPEs) instead of pure capacitances are applied to improve the fitting precision due to the distribution of relaxation times resulting from inhomogeneity at the electrode surface at nano/micro scale (e.g., roughness, porosity, etc.). The electrochemical corrosion properties include the resistance and capacitance for the two-layer oxidation film structure on specimen surface. Comparatively, the resistance of compact inner oxidation layer is larger leading to better corrosion resistance, while the resistance of loosened outer oxidation layer is less leading to inferior corrosion resistance. The reason lies in that the absorbability of loosened oxidation layer is more powerful, so the etchant solution absorbs into the loose pores of the oxidation layer causing the aggravation of corrosion.

3.2. Measurement and Analysis of Potentiodynamic Polarization Curve

Figure 4 presents the potentiodynamic polarization curves of the test material TA2 in different SBFs with varied glucose concentrations. The electrochemical corrosion parameters, such as the corrosion potential (Ecorr), the corrosion current (Icorr), the polarization resistance (Rp) as well as the anodic and cathodic Tafel slopes (βa and βc, respectively) determined by Tafel curves are summarized in Table 5.
It can be seen in Figure 4 that the implant material TA2 presents stimulated corrosion state under all investigated varied glucose concentrations. With the corrosion potential increasing, the corrosion current also enhances. With the glucose concentration in Hanks’ SBF increasing, the Tafel curve first shifts to the right (i.e., more passivating status) and then shifts to the left. The results indicate that the corrosion resistance of TA2 is the strongest under the glucose concentration of 10 mmol/L. When the corrosion voltage exceeds 0.5 V, the Tafel curves present the condition of passivating and the corrosion currents tend to be steady. It demonstrates that the deterioration and the formation of passivating film on TA2 specimen surface have reached a balance that is independent on the glucose concentration. According to the fitting results of polarization curves in Table 5, the corrosion potential of the specimen in the environment of glucose concentration with 10 mmol/L is the highest, which means that TA2 is the most difficult to be corroded under this glucose concentration. However, the specimen surface is very easy to be corroded once the oxidation film is damaged because the polarization resistance will be very small in this situation. It is attributed to that anions are prone to be adhesion upon the surface due to the promotion effect of glucose concentration, with which the passive film will be easily penetrated through, then the corrosion will happen.

3.3. Surface Observation

After removal of corrosion products and residual chemicals using ultrasonic cleaning with anhydrous ethanol, the scanning electron microscope (SEM) micrographs for the corrosion surface of TA2 electrode under different glucose concentrations were obtained as shown in Figure 5. Figure 5 shows the macro topography and microscopic morphology for the corrosion surfaces under the glucose concentrations of 5 mmol/L, 10 mmol/L, 12 mmol/L, 15 mmol/L and 20 mmol/L, respectively. It can be seen from Figure 5 that no pitting occurs on the corrosion surface under all investigated glucose concentrations, while a majority of area on the corrosion surface remains passivated state.
It can be seen from the microscopic morphology in Figure 5 that there are slight crevices observed on the corroded surface when the glucose concentrations are less than 20 mmol/L. Because there are chloridions (from NaCl, MgCl2 and KCl) in the Hanks’ SBF, the metal ions are apt to bind with the chloridions which leads to the surface corrosion. It demonstrates that the corrosion belongs to localized corrosion pattern and the corrosion rate is very low.
Figure 6 presents the three dimensional micrographs for the corroded surface of TA2 electrode obtained under the glucose concentration of 12 mmol/L. It can be seen that the corrosion rate of TA2 specimen in the Hanks’ SBF is very low and the corrosion depth on the surface is less than three micrometers. During the corrosion period of TA2 specimen, the effect of tiny corrosion on the implant can be neglected. However, when the metal irons dissolved into the body of receptor accumulate for a long time, they will do harm to the somatic function of the receptor which will cause inflammation or even endanger the life of the receptor [19,20].
The important information for corrosion behavior of TA2 implant material in Hanks’ SBF can be obtained based on the Tafel extrapolation method and the EIS measurement. With the increase of blood glucose concentration, the corrosion resistance of TA2 specimen first increases and then decreases. When the glucose concentration is 10 mmol/L, the corrosion resistance of TA2 specimen is the strongest. The research results have demonstrated that the pure titanium TA2 can be used as the implant material. Based on the lab experimental results, when the blood glucose concentration is normal or a bit higher than the normal value, the implant material of TA2 can maintain excellent corrosion resistance for a long time. The TA2 implant can be used to help receptor with no hyperglycemia to recover somatic function, but the receptor should keep blood glucose concentration in balance during the use of TA2 implant. Because the research results are obtained using lab experiments, the in vivo behavior of TA2 as implant material and its corrosion behavior in real body fluid should be re-examined.
However, for the hyperglycemia patients whose blood glucose concentration is much higher than the normal value, the corrosion rate and corrosion degree of TA2 implant will probably be much larger compared with those of normal receptors. This may cause the damage of pure titanium implant and lead to second damage to receptors.

4. Conclusions

This paper has investigated the corrosion behavior of pure titanium TA2 in Hanks’ SBF, through which the effect of blood glucose concentration on the surface corrosion for pure titanium TA2 has been revealed. The research results can provide theoretical foundation for clinical application of titanium implant. The research found that the pure titanium TA2 presented the best corrosion resistance within the glucose concentration of 10 mmol/L. It demonstrates that TA2 titanium can be used as the implant material at normal blood glucose concentration and a bit higher blood glucose concentration. The corrosion defects of crevice were observed on the TA2 material surface, but the corrosion rate for TA2 in Hanks’ SBF was very low. The oxidation film formed on the TA2 surface can protect the inner material from being corroded during initial corrosion stage. The corrosion behavior of pure titanium TA2 will happen easily once the passive film has been penetrated through. As a result, the implant material should avoid to be rubbed during surgery operation. When the blood glucose concentration is higher than 12 mmol/L for hyperglycemia patients, the corrosion rate for TA2 implant will accelerate quickly and the pure titanium implant cannot be used then. Thus, it should be cautioned for hyperglycemia patients to use such pure titanium implants. Research is also expected to provide technical supports to the surgery clinical application of titanium implants.

Acknowledgments

The authors would like to acknowledge the financial support from the National Natural Science Foundation of China (51375272), China Scholarship Council (CSC-201506220078) and the Talent Plan for Middle School Students. The authors would also like to thank Shuyong Zhang and Xiaohui Dai from School of Chemistry and Chemical Engineering of Shandong University for their instructions on the blood glucose concentration experiments.

Author Contributions

Conceived and designed the experiments: Shuyue Liu Performed the experiments: Shuyue Liu, Peirong Zhang Analyzed the data: Shuyue Liu, Peirong Zhang, Bing Wang. Wrote the paper: Shuyue Liu, Bing Wang.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Ezugwu, E.O.; Wang, Z.M. Titanium alloys and their machinability—A review. J. Mater. Process. Technol. 1997, 68, 262–274. [Google Scholar] [CrossRef]
  2. Harada, R.; Takemoto, S.; Kinoshita, H.; Yoshinari, M.; Kawada, E. Influence of sulfide concentration on the corrosion behavior of titanium in a artificial oral environment. Mater. Sci. Eng. C 2016, 62, 268–273. [Google Scholar] [CrossRef] [PubMed]
  3. Sun, Y.S.; Chang, J.H.; Huang, H.H. Corrosion resistance and biocompatibility of titanium surface coated with amorphous tantalum pentoxide. Thin Solid Films 2013, 528, 130–135. [Google Scholar] [CrossRef]
  4. Heo, D.N.; Ko, W.K.; Lee, H.R.; Lee, S.J.; Lee, D.; Um, S.H.; Lee, J.H.; Woo, Y.H.; Zhang, L.G.; Lee, D.W.; et al. Titanium dental implants surface-immobilized with gold nanoparticles as osteoinductive agents for rapid osseointegration. J. Colloid Interface Sci. 2016, 469, 129–137. [Google Scholar] [CrossRef] [PubMed]
  5. Giordano, C.; Saino, E.; Rimondini, L.; Pedeferri, M.P.; Visai, L.; Cigada, A.; Chiesa, R. Electrochemically induced anatase inhibits bacterial colonization on Titanium Grade 2 and Ti6Al4V alloy for dental and orthopedic devices. Colloids Surf. B Biointerfaces 2011, 88, 648–655. [Google Scholar] [CrossRef] [PubMed]
  6. Luo, Y.; Yang, L.; Tian, M. Application of biomedical-grade titanium alloys in trabecular bone and artificial joints. Biomater. Med. Tribol. 2013, 1, 181–216. [Google Scholar]
  7. Rubshtein, A.P.; Makarova, E.B.; Rinkevich, A.B.; Medvedeva, D.S.; Yakovenkova, L.I.; Vladimirov, A.B. Elastic properties of a porous titanium-bone tissue composite. Mater. Sci. Eng. C 2015, 52, 54–60. [Google Scholar] [CrossRef] [PubMed]
  8. Tian, Y.X.; Yu, Z.T.; Ong, C.Y.A.; Kent, D.; Wang, G. Microstructure, elastic deformation behavior and mechanical properties of biomedical β-type titanium alloy thin-tube used for stents. J. Mech. Behav. Biomed. Mater. 2015, 45, 132–141. [Google Scholar] [CrossRef] [PubMed]
  9. Choubey, A.; Balasubramaniam, R.; Basu, B. Effect of replacement of V by Nb and Fe on the electrochemical and corrosion behavior of Ti-6Al-4V in simulated physiological environment. J. Alloys Comp. 2004, 381, 288–294. [Google Scholar] [CrossRef]
  10. Cvijović-Alagić, I.; Cvijović, Z.; Mitrović, S.; Panić, V.; Rakin, M. Wear and corrosion behaviour of Ti-13Nb-13Zr and Ti-6Al-4V alloys in simulated physiological solution. Corros. Sci. 2011, 53, 796–808. [Google Scholar] [CrossRef]
  11. Shah, F.A.; Trobos, M.; Thomsen, P.; Palmquist, A. Commercially pure titanium (cp-Ti) versus titanium alloy (Ti6Al4V) materials as bone anchored implants—Is one truly better than the other? Mater. Sci. Eng. C 2016, 62, 960–966. [Google Scholar] [CrossRef] [PubMed]
  12. Kuromoto, N.K.; Simão, R.A.; Soares, G.A. Titanium oxide films produced on commercially pure titanium by anodic oxidation with different voltages. Mater. Charact. 2007, 58, 114–121. [Google Scholar] [CrossRef]
  13. Bhola, R.; Bhola, S.M.; Mishra, B.; Olson, D.L. Corrosion in titanium dental implants/prostheses—A review. Trends Biomater. Artif. Organs 2011, 25, 34–46. [Google Scholar]
  14. Kožuh, S.; Vrsalović, L.; Gojić, M.; Gudić, S.; Kosec, B. Comparison of the corrosion behavior and surface morphology of NiTi alloy and stainless steels in sodium chloride solution. J. Min. Metall. B. Metall. 2016, 52, 53–61. [Google Scholar] [CrossRef]
  15. Bovo, R. Simplified technique without skin flap for the bone-anchored hearing aid (BAHA) implant. Acta Otorhinolaryngol. Ital. 2008, 28, 252–255. [Google Scholar] [PubMed]
  16. Hultcrantz, M. Stability testing of a wide bone-anchored device after surgery without skin thinning. BioMed Res. Int. 2015, 2015, 853072. [Google Scholar] [CrossRef] [PubMed]
  17. Rogers, S.D.; Howie, D.W.; Graves, S.E.; Pearcy, M.J.; Haynes, D.R. In vitro human monocyte response to wear particles of titanium alloy containing vanadium or niobium. J. Bone Jt. Surg. Br. 1997, 79, 311–315. [Google Scholar] [CrossRef]
  18. Ruhl, J. Blood Sugar 101: What They Don’t Tell You about Diabetes; Technion Books: Turners Falls, MA, USA, 2008. [Google Scholar]
  19. Zhao, Y.P.; Wei, J.L.; Tian, Q.Y.; Liu, A.T.; Yi, Y.S.; Einhorn, T.A.; Liu, C.J. Progranulin suppresses titanium particle induced inflammatory osteolysis by targeting TNFα signaling. Sci. Rep. 2016, 6, 20909. [Google Scholar] [CrossRef] [PubMed]
  20. Longhofer, L.K.; Chong, A.; Strong, N.M.; Wooley, P.H.; Yang, S.Y. Specific material effects of wear-particle-induced inflammation and osteolysis at the bone–implant interface: A rat model. J. Orthop. Trans. 2017, 8, 5–11. [Google Scholar] [CrossRef]
Figure 1. Nyquist figure and enlarged view of high frequency area for TA2 under different glucose concentrations. (a) Nyquist figure; and (b) enlarged view of high frequency area.
Figure 1. Nyquist figure and enlarged view of high frequency area for TA2 under different glucose concentrations. (a) Nyquist figure; and (b) enlarged view of high frequency area.
Materials 09 00874 g001
Figure 2. Bode figure for TA2 under different glucose concentrations. (a) lg|Z| versus lgf curve; and (b) −θ versus lgf curve.
Figure 2. Bode figure for TA2 under different glucose concentrations. (a) lg|Z| versus lgf curve; and (b) −θ versus lgf curve.
Materials 09 00874 g002
Figure 3. Equivalent circuit diagram for TA2 within.
Figure 3. Equivalent circuit diagram for TA2 within.
Materials 09 00874 g003
Figure 4. Potentiodynamic polarization curves of TA2 in different SBFs with varied glucose concentrations.
Figure 4. Potentiodynamic polarization curves of TA2 in different SBFs with varied glucose concentrations.
Materials 09 00874 g004
Figure 5. SEM micrographs for the corroded surface of TA2 electrode under different glucose concentrations.
Figure 5. SEM micrographs for the corroded surface of TA2 electrode under different glucose concentrations.
Materials 09 00874 g005aMaterials 09 00874 g005b
Figure 6. Three dimensional micrograph for the corroded surface of TA2 electrode under glucose concentration of 12 mmol/L.
Figure 6. Three dimensional micrograph for the corroded surface of TA2 electrode under glucose concentration of 12 mmol/L.
Materials 09 00874 g006
Table 1. The range of blood glucose concentration for healthy people and hyperglycemia patient [18].
Table 1. The range of blood glucose concentration for healthy people and hyperglycemia patient [18].
Research ObjectBody EnvironmentBlood Glucose Concentration/mmol·L−1
Healthy peopleLimosis4.4–5.6
Two hours after diet≤7.8
Hyperglycemia patientLimosis>7.0
Two hours after diet≥11.1
Table 2. Experimental instruments.
Table 2. Experimental instruments.
Instrument NameSpecificationManufacturer
Electrochemical workstationCHI 604AShanghai Chenhua Instrument Co., Ltd. (Shanghai, China).
Vacuum drying ovenZKXF-1Shanghai Shuli Instrument Co., Ltd. (Shanghai, China).
Deionized water equipmentUPT-I-107Chengdu Chaochun Science and Technology Co., Ltd. (Chengdu, China).
Electronic scalesAUY 120Shimadzu Corporation (Shimane, Japan).
Working electrodeTA2Self-manufactured (Jinan, China).
Reference electrodeSaturated calomel electrodeShanghai Yidian Science Instrument Co., Ltd. (Shanghai, China).
Auxiliary electrodePlatinum gauze electrodeSelf-manufactured (Jinan, China).
Table 3. Analytic reagents used in the experiment.
Table 3. Analytic reagents used in the experiment.
Reagent NameChemical FormulaMolecular WeightPurityManufacturer
Sodium chlorideNaCl58.44Analytic reagentSinopharm Chemical Reagent Co., Ltd. (Shanghai, China).
Potassium chlorideKCl74.55Analytic reagentSinopharm Chemical Reagent Co., Ltd. (Shanghai, China).
Anhydrous calcium chlorideCaCl2110.99Analytic reagentShantou Xilong Chemical Factory (Shantou, China).
Sodium bicarbonateNaHCO384.01Analytic reagentShantou Xilong Chemical Factory (Shantou, China).
Magnesium chlorideMgCl2·6H2O203.3Analytic reagentTianjin Fuchen Chemical Reagent Factory (Tianjin, China).
Anhydrous magnesium sulfateMgSO4120.37Analytic reagentTianjin Guangcheng Chemical Reagent Co., Ltd. (Tianjin, China).
Monopotassium phosphateKH2PO4136.09Analytic reagentTianjin Hongyan Chemical Reagent Factory (Tianjin, China).
GlucoseC6H6O6·H2O198.17Analytic reagentSinopharm Chemical Reagent Co., Ltd. (Shanghai, China).
Disodium hydrogen phosphateNa2HPO4·12H2O358.14Analytic reagentSinopharm Chemical Reagent Co., Ltd. (Shanghai, China).
Deionized waterH2O18-Chengdu Chaochun Science and Technology, Ltd. (Chengdu, China).
Table 4. Dependence of electrochemical corrosion properties of TA2 electrode on glucose concentration.
Table 4. Dependence of electrochemical corrosion properties of TA2 electrode on glucose concentration.
Concentration/mmol·L−15710121520
Rs Ω14.210.00010.00025313.299 × 10−670.339.986 × 10−5
CPEe2.795 × 10−53.037 × 10−58.751 × 10−73.272 × 10−50.023735.904 × 10−7
ne0.91990.86910.68030.87480.75340.7168
Rp1742.533.9545.513748.9225.56
CPEd1.004 × 10−42.343 × 10−53.17 × 10−51.778 × 10−63.388 × 10−53.159 × 10−5
nd0.9480.40930.87330.65630.85310.8748
Rp26.057 × 1057.238 × 1057.439 × 1056.312 × 1058.308 × 1056.095 × 105
Table 5. Electrochemical corrosion parameters determined by Tafel curves.
Table 5. Electrochemical corrosion parameters determined by Tafel curves.
Glucose Concentration/mmol·L−1βa/V−1βc/V−1RpEcorr/VIcorr/A
53.5009.304179,383−0.4591.934 × 10−7
73.04513.787123,767−0.4102.087 × 10−7
102.77719.580113,090−0.3721.72 × 10−7
123.00713.824120,237−0.4052.149 × 10−7
153.30710.527147,625−0.4422.129 × 10−7
203.4279.328155,732−0.4452.189 × 10−7

Share and Cite

MDPI and ACS Style

Liu, S.; Wang, B.; Zhang, P. Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks’ Simulated Body Fluid. Materials 2016, 9, 874. https://doi.org/10.3390/ma9110874

AMA Style

Liu S, Wang B, Zhang P. Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks’ Simulated Body Fluid. Materials. 2016; 9(11):874. https://doi.org/10.3390/ma9110874

Chicago/Turabian Style

Liu, Shuyue, Bing Wang, and Peirong Zhang. 2016. "Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks’ Simulated Body Fluid" Materials 9, no. 11: 874. https://doi.org/10.3390/ma9110874

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop