- freely available
- re-usable
Int. J. Environ. Res. Public Health 2013, 10(1), 347-360; doi:10.3390/ijerph10010347
Article
Evaluation of Full-Facepiece Respirator Fit on Fire Fighters in the Municipality of Jeddah, Saudi Arabia
Department of Environmental Sciences, Faculty of Meteorology, Environment and Arid Land Agriculture, King Abdulaziz University, P.O. Box 80208, Jeddah 21589, Saudi Arabia
Received: 11 November 2012; in revised form: 12 December 2012 / Accepted: 5 January 2013 / Published: 14 January 2013
Abstract: The purpose of this study was to assess the effect of personal variables on the fit of the respirators used by firefighters and workers in highly polluted environments. However, resistance from many plants managers was met to conduct the study on their workers. Therefore, we were forced to limit the study on firefighters who were found very cooperative. Forty volunteer firefighters from different departments participated in the study. They were subjected to a daily leak rate measurement using a Control Negative Pressure (CNP) fit tester for five consecutive days. Two types of respirators were used for each volunteer: the Drager type and the MSA. At the end of the study, the association between face shape and presence of beard with the respirator leak rates was investigated. A significant difference in the leak rate was detected between the two types of respirators used, with the Drager respirator having higher leak rates. The presence of a beard increased dramatically the leak rate whatever the face shape was. The oval shape was the best fitting to the respirators, followed by the rounded and finally the rectangular face. The study recommends that personal variables like face shape must be taken into consideration and fit testing must be carried out periodically, to specify the respirator that best fits each firefighter. Having beard must be absolutely prohibited, since it can be life threatening in environmental dangerous conditions such those encountered during extinguishing fires and overhaul situations.
Keywords: respirator; firefighters; Control Negative Pressure; leak rate; face shape; full-face piece
Article Statistics
Click here to load and display the download statistics.Cite This Article
MDPI and ACS Style
Balkhyour, M.A. Evaluation of Full-Facepiece Respirator Fit on Fire Fighters in the Municipality of Jeddah, Saudi Arabia. Int. J. Environ. Res. Public Health 2013, 10, 347-360.
AMA StyleBalkhyour MA. Evaluation of Full-Facepiece Respirator Fit on Fire Fighters in the Municipality of Jeddah, Saudi Arabia. International Journal of Environmental Research and Public Health. 2013; 10(1):347-360.
Chicago/Turabian StyleBalkhyour, Mansour A. 2013. "Evaluation of Full-Facepiece Respirator Fit on Fire Fighters in the Municipality of Jeddah, Saudi Arabia." Int. J. Environ. Res. Public Health 10, no. 1: 347-360.
Int. J. Environ. Res. Public Health
EISSN 1660-4601
Published by MDPI AG, Basel, Switzerland
RSS
E-Mail Table of Contents Alert
