Sensors 2018, 18(2), 539; doi:10.3390/s18020539

A COTS-Based Portable System to Conduct Accurate Substance Concentration Measurements

1
Department of Information and Communication Technologies (TIC), Technical University of Cartagena, ETSIT, Campus Muralla del Mar, E-30202 Cartagena, Spain
2
Center for Electrochemistry and Intelligent Materials (CEMI), Technical University of Cartagena, ETSII, Campus Alfonso XIII, E-30203 Cartagena, Spain
*
Author to whom correspondence should be addressed.
Received: 22 December 2017 / Revised: 1 February 2018 / Accepted: 7 February 2018 / Published: 10 February 2018
(This article belongs to the Special Issue State-of-the-Art Sensors Technology in Spain 2017)
View Full-Text   |   Download PDF [3274 KB, uploaded 10 February 2018]   |  

Abstract

Traditionally, electrochemical procedures aimed at determining substance concentrations have required a costly and cumbersome laboratory environment. Specialized equipment and personnel obtain precise results under complex and time-consuming settings. Innovative electrochemical-based sensors are emerging to alleviate this difficulty. However, they are generally scarce, proprietary hardware and/or software, and focused only on measuring a restricted range of substances. In this paper, we propose a portable, flexible, low-cost system, built from commercial off-the-shelf components and easily controlled, using open-source software. The system is completed with a wireless module, which enables the transmission of measurements to a remote database for their later processing. A well-known PGSTAT100 Autolab device is employed to validate the effectiveness of our proposal. To this end, we select ascorbic acid as the substance under consideration, evaluating the reliability figure and obtaining the calibration curves for both platforms. The final outcomes are shown to be feasible, accurate, and repeatable. View Full-Text
Keywords: screen-printed electrode; potentiostat; cyclic voltammetry screen-printed electrode; potentiostat; cyclic voltammetry
Figures

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0).

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

SciFeed Share & Cite This Article

MDPI and ACS Style

Aznar-Poveda, J.; Lopez-Pastor, J.A.; Garcia-Sanchez, A.-J.; Garcia-Haro, J.; Otero, T.F. A COTS-Based Portable System to Conduct Accurate Substance Concentration Measurements. Sensors 2018, 18, 539.

Show more citation formats Show less citations formats

Note that from the first issue of 2016, MDPI journals use article numbers instead of page numbers. See further details here.

Related Articles

Article Metrics

Article Access Statistics

1

Comments

[Return to top]
Sensors EISSN 1424-8220 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert
Back to Top