Next Article in Journal
A Quartz Crystal Microbalance Immunosensor for Stem Cell Selection and Extraction
Next Article in Special Issue
Extraction and Analysis of Respiratory Motion Using Wearable Inertial Sensor System during Trunk Motion
Previous Article in Journal
Development of a High Precision Displacement Measurement System by Fusing a Low Cost RTK-GPS Sensor and a Force Feedback Accelerometer for Infrastructure Monitoring
Previous Article in Special Issue
Adaptive Spatial Filter Based on Similarity Indices to Preserve the Neural Information on EEG Signals during On-Line Processing
Article Menu
Issue 12 (December) cover image

Export Article

Open AccessArticle
Sensors 2017, 17(12), 2749; https://doi.org/10.3390/s17122749

Mathematical Model for Localised and Surface Heat Flux of the Human Body Obtained from Measurements Performed with a Calorimetry Minisensor

Departamento de Física, Universidad de Las Palmas de Gran Canaria, E-35017 Las Palmas de Gran Canaria, Spain
*
Author to whom correspondence should be addressed.
Received: 10 October 2017 / Revised: 18 November 2017 / Accepted: 21 November 2017 / Published: 28 November 2017
(This article belongs to the Special Issue Biomedical Sensors and Systems 2017)
View Full-Text   |   Download PDF [6581 KB, uploaded 28 November 2017]   |  

Abstract

The accuracy of the direct and local measurements of the heat power dissipated by the surface of the human body, using a calorimetry minisensor, is directly related to the calibration rigor of the sensor and the correct interpretation of the experimental results. For this, it is necessary to know the characteristics of the body’s local heat dissipation. When the sensor is placed on the surface of the human body, the body reacts until a steady state is reached. We propose a mathematical model that represents the rate of heat flow at a given location on the surface of a human body by the sum of a series of exponentials: W(t) = A0 + ∑Aiexp(−t/τi). In this way, transient and steady states of heat dissipation can be interpreted. This hypothesis has been tested by simulating the operation of the sensor. At the steady state, the power detected in the measurement area (4 cm2) varies depending on the sensor’s thermostat temperature, as well as the physical state of the subject. For instance, for a thermostat temperature of 24 °C, this power can vary between 100–250 mW in a healthy adult. In the transient state, two exponentials are sufficient to represent this dissipation, with 3 and 70 s being the mean values of its time constants. View Full-Text
Keywords: direct calorimetry; heat conduction calorimeters; isothermal calorimeters; medical calorimetry; non-differential calorimeters direct calorimetry; heat conduction calorimeters; isothermal calorimeters; medical calorimetry; non-differential calorimeters
Figures

Figure 1

This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0).
SciFeed

Share & Cite This Article

MDPI and ACS Style

Socorro, F.; Rodríguez de Rivera, P.J.; Rodríguez de Rivera, M.; Rodríguez de Rivera, M. Mathematical Model for Localised and Surface Heat Flux of the Human Body Obtained from Measurements Performed with a Calorimetry Minisensor. Sensors 2017, 17, 2749.

Show more citation formats Show less citations formats