Sensors 2013, 13(4), 4214-4224; doi:10.3390/s130404214
Article

Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor

* ,
,
,
,
 and
Received: 6 February 2013; in revised form: 23 March 2013 / Accepted: 25 March 2013 / Published: 28 March 2013
View Full-Text   |   Download PDF [754 KB, uploaded 21 June 2014]
Abstract: In this study, we have first developed a rapid and sensitive strip immunosensor based on two heterogeneously-sized gold nanoparticles (Au NPs) probes for the detection of trace lead ions in drinking water. The sensitivity was 4-fold higher than that of the conventional LFA under the optimized conditions. The visual limit of detection (LOD) of the amplified method for qualitative detection lead ions was 2 ng/mL and the LOD for semi-quantitative detection could go down to 0.19 ng/mL using a scanning reader. The method suffered from no interference from other metal ions and could be used to detect trace lead ions in drinking water without sample enrichment. The recovery of the test samples ranged from 96% to 103%. As the detection method could be accomplished within 15 min, this method could be used as a potential tool for preliminary monitoring of lead contamination in drinking water.
Keywords: amplified competitive lateral flow assay; lead ions; immunosensor; gold nanoparticles amplified competitive lateral flow assay; lead ions; immunosensor; gold nanoparticles
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Export to BibTeX |
EndNote


MDPI and ACS Style

Kuang, H.; Xing, C.; Hao, C.; Liu, L.; Wang, L.; Xu, C. Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor. Sensors 2013, 13, 4214-4224.

AMA Style

Kuang H, Xing C, Hao C, Liu L, Wang L, Xu C. Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor. Sensors. 2013; 13(4):4214-4224.

Chicago/Turabian Style

Kuang, Hua; Xing, Changrui; Hao, Changlong; Liu, Liqiang; Wang, Libing; Xu, Chuanlai. 2013. "Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor." Sensors 13, no. 4: 4214-4224.



Sensors EISSN 1424-8220 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert