Development of a Fully Automated Flow Injection Analyzer Implementing Bioluminescent Biosensors for Water Toxicity Assessment
1
Chemistry Laboratory, Agricultural University of Athens, 75 Iera Odos, 118 55 Athens, Greece
2
Microbiology Laboratory, Agricultural University of Athens, 75 Iera Odos, 118 55 Athens, Greece
* Author to whom correspondence should be addressed.
Received: 11 May 2010; in revised form: 2 June 2010 / Accepted: 12 July 2010 / Published: 27 July 2010
Abstract: This paper describes the development of an automated Flow Injection analyzer for water toxicity assessment. The analyzer is validated by assessing the toxicity of heavy metal (Pb2+, Hg2+ and Cu2+) solutions. One hundred μL of a Vibrio fischeri suspension are injected in a carrier solution containing different heavy metal concentrations. Biosensor cells are mixed with the toxic carrier solution in the mixing coil on the way to the detector. Response registered is % inhibition of biosensor bioluminescence due to heavy metal toxicity in comparison to that resulting by injecting the Vibrio fischeri suspension in deionised water. Carrier solutions of mercury showed higher toxicity than the other heavy metals, whereas all metals show concentration related levels of toxicity. The biosensor’s response to carrier solutions of different pHs was tested. Vibrio fischeri’s bioluminescence is promoted in the pH 5–10 range. Experiments indicate that the whole cell biosensor, as applied in the automated fluidic system, responds to various toxic solutions.
Keywords: Vibrio fischeri; toxicity; flow injection
Article Statistics
Click here to load and display the download statistics.
Notes: Multiple requests from the same IP address are counted as one view. Statistics are updated once per day.
Cite This Article
MDPI and ACS Style
Komaitis, E.; Vasiliou, E.; Kremmydas, G.; Georgakopoulos, D.G.; Georgiou, C. Development of a Fully Automated Flow Injection Analyzer Implementing Bioluminescent Biosensors for Water Toxicity Assessment. Sensors 2010, 10, 7089-7098.
AMA Style
Komaitis E., Vasiliou E., Kremmydas G., Georgakopoulos D.G., Georgiou C. Development of a Fully Automated Flow Injection Analyzer Implementing Bioluminescent Biosensors for Water Toxicity Assessment. Sensors. 2010; 10(8):7089-7098.
Chicago/Turabian Style
Komaitis, Efstratios; Vasiliou, Efstathios; Kremmydas, Gerasimos; Georgakopoulos, Dimitrios G.; Georgiou, Constantinos. 2010. "Development of a Fully Automated Flow Injection Analyzer Implementing Bioluminescent Biosensors for Water Toxicity Assessment." Sensors 10, no. 8: 7089-7098.