Sensors 2010, 10(8), 7089-7098; doi:10.3390/s100807089
Article

Development of a Fully Automated Flow Injection Analyzer Implementing Bioluminescent Biosensors for Water Toxicity Assessment

1email, 1email, 2email, 2email and 1,* email
Received: 11 May 2010; in revised form: 2 June 2010 / Accepted: 12 July 2010 / Published: 27 July 2010
(This article belongs to the Section Biosensors)
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abstract: This paper describes the development of an automated Flow Injection analyzer for water toxicity assessment. The analyzer is validated by assessing the toxicity of heavy metal (Pb2+, Hg2+ and Cu2+) solutions. One hundred μL of a Vibrio fischeri suspension are injected in a carrier solution containing different heavy metal concentrations. Biosensor cells are mixed with the toxic carrier solution in the mixing coil on the way to the detector. Response registered is % inhibition of biosensor bioluminescence due to heavy metal toxicity in comparison to that resulting by injecting the Vibrio fischeri suspension in deionised water. Carrier solutions of mercury showed higher toxicity than the other heavy metals, whereas all metals show concentration related levels of toxicity. The biosensor’s response to carrier solutions of different pHs was tested. Vibrio fischeri’s bioluminescence is promoted in the pH 5–10 range. Experiments indicate that the whole cell biosensor, as applied in the automated fluidic system, responds to various toxic solutions.
Keywords: Vibrio fischeri; toxicity; flow injection
PDF Full-text Download PDF Full-Text [293 KB, Updated Version, uploaded 21 June 2014 03:06 CEST]
The original version is still available [312 KB, uploaded 21 June 2014 03:06 CEST]

Export to BibTeX |
EndNote


MDPI and ACS Style

Komaitis, E.; Vasiliou, E.; Kremmydas, G.; Georgakopoulos, D.G.; Georgiou, C. Development of a Fully Automated Flow Injection Analyzer Implementing Bioluminescent Biosensors for Water Toxicity Assessment. Sensors 2010, 10, 7089-7098.

AMA Style

Komaitis E, Vasiliou E, Kremmydas G, Georgakopoulos DG, Georgiou C. Development of a Fully Automated Flow Injection Analyzer Implementing Bioluminescent Biosensors for Water Toxicity Assessment. Sensors. 2010; 10(8):7089-7098.

Chicago/Turabian Style

Komaitis, Efstratios; Vasiliou, Efstathios; Kremmydas, Gerasimos; Georgakopoulos, Dimitrios G.; Georgiou, Constantinos. 2010. "Development of a Fully Automated Flow Injection Analyzer Implementing Bioluminescent Biosensors for Water Toxicity Assessment." Sensors 10, no. 8: 7089-7098.

Sensors EISSN 1424-8220 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert