<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xml:lang="en" article-type="review-article">
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Sensors</journal-id>
<journal-title>Sensors</journal-title>
<issn pub-type="epub">1424-8220</issn>
<publisher>
<publisher-name>Molecular Diversity Preservation International (MDPI)</publisher-name></publisher></journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.3390/s101211556</article-id>
<article-id pub-id-type="publisher-id">sensors-10-11556</article-id>
<article-categories>
<subj-group>
<subject>Review</subject></subj-group></article-categories>
<title-group>
<article-title>The Use of Wearable Inertial Motion Sensors in Human Lower Limb Biomechanics Studies: A Systematic Review</article-title></title-group>
<contrib-group>
<contrib contrib-type="author">
<name><surname>Fong</surname><given-names>Daniel Tik-Pui</given-names></name><xref ref-type="aff" rid="af1-sensors-10-11556">1</xref><xref ref-type="aff" rid="af2-sensors-10-11556">2</xref><xref ref-type="corresp" rid="c1-sensors-10-11556">*</xref></contrib>
<contrib contrib-type="author">
<name><surname>Chan</surname><given-names>Yue-Yan</given-names></name><xref ref-type="aff" rid="af1-sensors-10-11556">1</xref><xref ref-type="aff" rid="af2-sensors-10-11556">2</xref><xref ref-type="aff" rid="af3-sensors-10-11556">3</xref></contrib></contrib-group>
<aff id="af1-sensors-10-11556">
<label>1</label> Department of Orthopaedics and Traumatology, Prince of Wales Hospital, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China</aff>
<aff id="af2-sensors-10-11556">
<label>2</label> The Hong Kong Jockey Club Sports Medicine and Health Sciences Centre, Faculty of Medicine, The Chinese University of Hong Kong, Hong Kong, China</aff>
<aff id="af3-sensors-10-11556">
<label>3</label> Department of Orthopaedics and Traumatology, Alice Ho Miu Ling Nethersole Hospital, Hong Kong, China</aff>
<author-notes>
<corresp id="c1-sensors-10-11556">
<label>*</label>Author to whom correspondence should be addressed; E-Mail: <email>dfong@ort.cuhk.edu.hk</email>; Tel.: +852-2632-3535; Fax: +852-2646-3020.</corresp></author-notes>
<pub-date pub-type="collection">
<year>2010</year></pub-date>
<pub-date pub-type="epub">
<day>16</day>
<month>12</month>
<year>2010</year></pub-date>
<volume>10</volume><issue>12</issue>
<fpage>11556</fpage>
<lpage>11565</lpage>
<history>
<date date-type="received">
<day>1</day>
<month>11</month>
<year>2010</year></date>
<date date-type="rev-recd">
<day>1</day>
<month>12</month>
<year>2010</year></date>
<date date-type="accepted">
<day>14</day>
<month>12</month>
<year>2010</year></date></history>
<permissions>
<copyright-statement>© 2010 by the authors; licensee MDPI, Basel, Switzerland.</copyright-statement>
<copyright-year>2010</copyright-year>
<license>
<p>This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (<ext-link xlink:href="http://creativecommons.org/licenses/by/3.0/" ext-link-type="uri">http://creativecommons.org/licenses/by/3.0/</ext-link>).</p></license></permissions>
<abstract>
<p>Wearable motion sensors consisting of accelerometers, gyroscopes and magnetic sensors are readily available nowadays. The small size and low production costs of motion sensors make them a very good tool for human motions analysis. However, data processing and accuracy of the collected data are important issues for research purposes. In this paper, we aim to review the literature related to usage of inertial sensors in human lower limb biomechanics studies. A systematic search was done in the following search engines: ISI Web of Knowledge, Medline, SportDiscus and IEEE Xplore. Thirty nine full papers and conference abstracts with related topics were included in this review. The type of sensor involved, data collection methods, study design, validation methods and its applications were reviewed.</p></abstract>
<kwd-group>
<kwd>inertial sensors</kwd>
<kwd>accelerometers</kwd>
<kwd>gyroscopes</kwd>
<kwd>magnetic sensors</kwd>
<kwd>joint kinematics</kwd>
<kwd>motion analysis</kwd></kwd-group></article-meta></front>
<body>
<sec sec-type="intro">
<label>1.</label>
<title>Introduction</title>
<p>Wearable inertial motion sensors consisting of accelerometers, gyroscopes and magnetic sensors are readily available nowadays [<xref ref-type="bibr" rid="b1-sensors-10-11556">1</xref>]. Some companies, such as XSens Technologies (The Netherlands) and Innalabs (Russia) provide inertial motion sensor solutions. They are highly transportable, no stationary units, such as receivers and cameras are needed for data collection, therefore can be used outside laboratory conditions [<xref ref-type="bibr" rid="b2-sensors-10-11556">2</xref>]. Inertial motion sensor is a good choice for human biomechanics studies because it is highly transportable, low cost and consumes low power during operation.</p>
<p>Accelerometers have been adopted in human joint kinematics studies since 1990s. Willemsen [<xref ref-type="bibr" rid="b3-sensors-10-11556">3</xref>] and Heyn [<xref ref-type="bibr" rid="b4-sensors-10-11556">4</xref>] applied uniaxial accelerometers on aluminum strips, which were then attached on the foot, shank, thigh and pelvis of subjects by Velcro straps. In their studies, four accelerometers on rigid metal plates were needed on each segment, otherwise they would have had to numerically integrate twice the angular acceleration of the segment to get the joint angle [<xref ref-type="bibr" rid="b5-sensors-10-11556">5</xref>]. Therefore a total of eight accelerometers were needed to estimate joint kinematics. Only uniaxial joint kinematics could be obtained. Also, in both studies, leg segments were assumed to be rigid bodies, and the joints were single axis hinge joint. These simplified joint models were good for simple motion analysis, for example two dimensional single joint motion analysis.</p>
<p>Simplified systems were developed in 2000s. Data from accelerometers and gyroscope could be used to estimate orientation relative to an inertial frame [<xref ref-type="bibr" rid="b1-sensors-10-11556">1</xref>]. Although relative orientation could be estimated by integration of data from gyroscope, errors would accumulate by this method, which caused distortion and drift errors. Accelerometer can be used to compensate the drift of the gyroscope about the axes of the horizontal plane, while magnetic sensor which located orientation by earth’s magnetic field was adopted to solve this drift problem about the vertical axis [<xref ref-type="bibr" rid="b6-sensors-10-11556">6</xref>]. However, inside reinforced-concrete-covered buildings, the magnetic field on the earth was always perturbated. Further development of high accuracy three dimensional relative orientations was developed by Favre and his colleagues [<xref ref-type="bibr" rid="b7-sensors-10-11556">7</xref>]. Favre and his colleagues integrated angular velocity data obtained from gyroscopes, and then corrected the angle estimation based on inclination data from accelerometers gathered during rest or constant velocity motion period. Known joint anatomical constraints were also considered for better estimation in a later study [<xref ref-type="bibr" rid="b8-sensors-10-11556">8</xref>]. Static calibration in a defined position was still needed. Cooper [<xref ref-type="bibr" rid="b1-sensors-10-11556">1</xref>] and his colleagues extended the measurements in dynamic activities. However, Cooper’s studies only involved a simplified model of a single hinge knee joint, further extension of the technique was needed for three dimensional measurements.</p></sec>
<sec sec-type="methods">
<label>2.</label>
<title>Methods</title>
<p>The research method was graphically displayed in <xref ref-type="fig" rid="f1-sensors-10-11556">Figure 1</xref> for better understanding of the procedure. Systematic literature search of Medline (from 1966), ISI Web of Knowledge (Science Citation Index Expanded, from 1985; Social Sciences Citation Index, from 1956; Arts &amp; Humanities Citation Index, from 1975), SportDiscus (from 1975) and IEEE Xplore was conducted at the last week of July in year 2010. The four databases were chosen as they were popular search engines which cover most of the literature in engineering, medicine and sports biomechanics field. The searched keyword string was “(biomechanics OR injury prevention OR kinematics) AND (lower limb OR knee OR hip OR ankle) AND (inertial sensor OR accelerometer OR gyroscope OR gyrometer OR magnetic sensor OR magnetrometer)” appeared in title, abstract, and keyword fields. The initial total number of identified articles from these databases was 195. Fifty four duplicated entries were moved, therefore 141 articles were left. Three articles not written in English were excluded, the number of articles were further reduced to 138. These 138 full papers were obtained from the library in The Chinese University of Hong Kong as well as from online search. The title and abstract of each entry was read, non-related studies were excluded, 36 full papers and conference abstract were left. Three more papers in related topic were added manually [<xref ref-type="bibr" rid="b9-sensors-10-11556">9</xref>–<xref ref-type="bibr" rid="b11-sensors-10-11556">11</xref>], therefore, a total of 39 full papers and conference abstract were included in this review. Inclusion criteria were as follow: (1) The study reported lower limb joint kinematics; and (2) The study involves accelerometers, gyroscopes and/or magnetic sensors. However, articles only contain the following content were excluded: (1) <italic>In vivo</italic> and <italic>in vitro</italic> kinematics studies; (2) Joint kinematics data not obtained from accelerometers, gyroscopes or magnetic sensors and (3) Frequency analysis.</p></sec>
<sec sec-type="results|discussion">
<label>3.</label>
<title>Results and Discussion</title>
<sec>
<label>3.1.</label>
<title>Type of Sensors</title>
<p>Type of sensors used ranged from uniaxial accelerometers to triaxial accelerometers, gyroscopes and magnetic sensor. Full scale of accelerometers ranged from 3 g to 10 g, those of gyroscope ranged from 300–1,200 degree/second. For magnetic sensors, the full scale was 750 mGauss [<xref ref-type="bibr" rid="b12-sensors-10-11556">12</xref>,<xref ref-type="bibr" rid="b13-sensors-10-11556">13</xref>]. The weight of motion sensors adopted ranged from 18.2 g to 700 g, and the size ranged from 20 × 10 × 7.2 mm<sup>3</sup> to 64 × 62 × 26 mm<sup>3</sup>. Sampling frequencies of these systems ranged from 20–800 Hz. Details of sensors used in the studies were shown in <xref ref-type="table" rid="t1-sensors-10-11556">Table 1</xref>.</p></sec>
<sec sec-type="methods">
<label>3.2.</label>
<title>Data Logging and Processing</title>
<p>In most of the reviewed papers, collected data was not processed in a real time basis. Some of the systems have its own data logging system attached on the subject’s body. Portable data loggers with different types of memory cards, for example, flash memories and SD-micro cards [<xref ref-type="bibr" rid="b1-sensors-10-11556">1</xref>,<xref ref-type="bibr" rid="b8-sensors-10-11556">8</xref>,<xref ref-type="bibr" rid="b16-sensors-10-11556">16</xref>,<xref ref-type="bibr" rid="b20-sensors-10-11556">20</xref>,<xref ref-type="bibr" rid="b25-sensors-10-11556">25</xref>,<xref ref-type="bibr" rid="b27-sensors-10-11556">27</xref>,<xref ref-type="bibr" rid="b31-sensors-10-11556">31</xref>] were one of the common methods for data logging. These memory cards allow handy data storage. There were also systems which required subjects to carry a hand held PC with them for data collection [<xref ref-type="bibr" rid="b34-sensors-10-11556">34</xref>]. Hand held PC allows data collection in daily activities as they can be carried in pocket easily. However, their sizes were still not small enough for subjects performing vigorous sport motions. Wired systems which data were collected by a wired notebook PC also existed [<xref ref-type="bibr" rid="b17-sensors-10-11556">17</xref>,<xref ref-type="bibr" rid="b30-sensors-10-11556">30</xref>]. Bluetooth wireless communication was also adopted [<xref ref-type="bibr" rid="b9-sensors-10-11556">9</xref>,<xref ref-type="bibr" rid="b33-sensors-10-11556">33</xref>], which allows subjects to have more freedom of motion during data collection. However, workstation must present for data collection, therefore it is not suitable for ambulatory system.</p>
<p>One of the disadvantages of application of wearable sensors in human motion analysis was that noise in data collection was usually severe. Therefore, data have to be filtered before further processing. Low pass filters with cut off frequencies ranged from 15–40 Hz were adopted in various systems [<xref ref-type="bibr" rid="b2-sensors-10-11556">2</xref>,<xref ref-type="bibr" rid="b3-sensors-10-11556">3</xref>,<xref ref-type="bibr" rid="b6-sensors-10-11556">6</xref>,<xref ref-type="bibr" rid="b26-sensors-10-11556">26</xref>,<xref ref-type="bibr" rid="b29-sensors-10-11556">29</xref>]. The cut off frequencies were chosen carefully based on the motions being performed. Butterworth filters [<xref ref-type="bibr" rid="b17-sensors-10-11556">17</xref>,<xref ref-type="bibr" rid="b26-sensors-10-11556">26</xref>], Kalman filters [<xref ref-type="bibr" rid="b1-sensors-10-11556">1</xref>,<xref ref-type="bibr" rid="b10-sensors-10-11556">10</xref>,<xref ref-type="bibr" rid="b37-sensors-10-11556">37</xref>] and Savitzky-Golay filters [<xref ref-type="bibr" rid="b18-sensors-10-11556">18</xref>,<xref ref-type="bibr" rid="b19-sensors-10-11556">19</xref>] were also adopted in some other systems according to their applications and motions to be detected (<xref ref-type="table" rid="t2-sensors-10-11556">Table 2</xref>). Curved fitting technique was also adopted to eliminate noise [<xref ref-type="bibr" rid="b33-sensors-10-11556">33</xref>].</p></sec>
<sec sec-type="methods">
<label>3.3.</label>
<title>Study Design and Validation</title>
<p>Most of the studies reviewed recruited young (age 18–40) healthy individuals as subjects. Only two studies have older subjects with average age of aged 58.7 [<xref ref-type="bibr" rid="b18-sensors-10-11556">18</xref>,<xref ref-type="bibr" rid="b19-sensors-10-11556">19</xref>]. Sample size ranged from one to 36. Walking and running on flat ground or treadmill were common motions being analyzed [<xref ref-type="bibr" rid="b1-sensors-10-11556">1</xref>,<xref ref-type="bibr" rid="b2-sensors-10-11556">2</xref>,<xref ref-type="bibr" rid="b4-sensors-10-11556">4</xref>,<xref ref-type="bibr" rid="b8-sensors-10-11556">8</xref>,<xref ref-type="bibr" rid="b14-sensors-10-11556">14</xref>,<xref ref-type="bibr" rid="b16-sensors-10-11556">16</xref>–<xref ref-type="bibr" rid="b18-sensors-10-11556">18</xref>,<xref ref-type="bibr" rid="b21-sensors-10-11556">21</xref>,<xref ref-type="bibr" rid="b22-sensors-10-11556">22</xref>,<xref ref-type="bibr" rid="b24-sensors-10-11556">24</xref>,<xref ref-type="bibr" rid="b27-sensors-10-11556">27</xref>,<xref ref-type="bibr" rid="b29-sensors-10-11556">29</xref>,<xref ref-type="bibr" rid="b31-sensors-10-11556">31</xref>,<xref ref-type="bibr" rid="b34-sensors-10-11556">34</xref>,<xref ref-type="bibr" rid="b36-sensors-10-11556">36</xref>,<xref ref-type="bibr" rid="b37-sensors-10-11556">37</xref>,<xref ref-type="bibr" rid="b39-sensors-10-11556">39</xref>]. However, some other specific motions were also involved, for example, walking on difference surfaces [<xref ref-type="bibr" rid="b26-sensors-10-11556">26</xref>], stand-sit transition [<xref ref-type="bibr" rid="b34-sensors-10-11556">34</xref>], landing from a fall [<xref ref-type="bibr" rid="b15-sensors-10-11556">15</xref>], tennis serve [<xref ref-type="bibr" rid="b38-sensors-10-11556">38</xref>], rowing, cycling [<xref ref-type="bibr" rid="b20-sensors-10-11556">20</xref>], jumping, walking downstairs, cutting, simulated sprain [<xref ref-type="bibr" rid="b17-sensors-10-11556">17</xref>], walking upstairs [<xref ref-type="bibr" rid="b2-sensors-10-11556">2</xref>], knee and ankle joint movement [<xref ref-type="bibr" rid="b6-sensors-10-11556">6</xref>,<xref ref-type="bibr" rid="b11-sensors-10-11556">11</xref>,<xref ref-type="bibr" rid="b30-sensors-10-11556">30</xref>].</p>
<p>The accuracies of the motion sensing systems were mostly compared with those of video cameras or high speed optical motion analysis systems with reflexive markers, as video cameras and optical motion analysis systems were commonly used for human joint kinematics assessment nowadays.</p></sec>
<sec>
<label>3.4.</label>
<title>Applications</title>
<p>The reviewed papers monitored the joint kinematics of ankles, knees and hips. Most of the studies simplified these joints as simple hinge joints, which assume only sagittal plane movement was allowed. However, some studies could provide detailed three dimensional descriptions for ankle, knee and hip joints. Tibial acceleration was other commonly recorded parameters for human motion analysis. Tibial acceleration can be easily obtained from accelerometer data, without complicated data processing, therefore was favorable for real time monitoring and classification of different human activities.</p>
<p>By analysis of lower limb joint kinematics, several applications could be done, for example: Analysis of skill level and locomotor performance of athletes or patients [<xref ref-type="bibr" rid="b24-sensors-10-11556">24</xref>,<xref ref-type="bibr" rid="b27-sensors-10-11556">27</xref>,<xref ref-type="bibr" rid="b38-sensors-10-11556">38</xref>]; ambulatory measurement to monitor patients’ daily activities [<xref ref-type="bibr" rid="b7-sensors-10-11556">7</xref>,<xref ref-type="bibr" rid="b8-sensors-10-11556">8</xref><xref ref-type="bibr" rid="b16-sensors-10-11556">16</xref>,<xref ref-type="bibr" rid="b29-sensors-10-11556">29</xref>]; clinical assessment for patients [<xref ref-type="bibr" rid="b13-sensors-10-11556">13</xref>,<xref ref-type="bibr" rid="b30-sensors-10-11556">30</xref>]; Gait event detection and analysis [<xref ref-type="bibr" rid="b1-sensors-10-11556">1</xref>,<xref ref-type="bibr" rid="b18-sensors-10-11556">18</xref>,<xref ref-type="bibr" rid="b22-sensors-10-11556">22</xref>,<xref ref-type="bibr" rid="b23-sensors-10-11556">23</xref>,<xref ref-type="bibr" rid="b26-sensors-10-11556">26</xref>,<xref ref-type="bibr" rid="b37-sensors-10-11556">37</xref>,<xref ref-type="bibr" rid="b39-sensors-10-11556">39</xref>] and identification of different daily activities, for example stair climbing, walking, running, rowing, cycling and simulated ankle sprain [<xref ref-type="bibr" rid="b2-sensors-10-11556">2</xref>,<xref ref-type="bibr" rid="b17-sensors-10-11556">17</xref>,<xref ref-type="bibr" rid="b20-sensors-10-11556">20</xref>].</p></sec>
<sec sec-type="methods">
<label>3.5.</label>
<title>Fixation Methods</title>
<p>Fixation methods were a very important part in motion analysis using motion sensors. A good fixation method reduced the artifices of skin movement. Moreover, good fixation methods can greatly reduced the errors caused by improper alignment to anatomical axes. Velcro straps [<xref ref-type="bibr" rid="b3-sensors-10-11556">3</xref>,<xref ref-type="bibr" rid="b30-sensors-10-11556">30</xref>], double-side adhesive tape [<xref ref-type="bibr" rid="b39-sensors-10-11556">39</xref>], elastic straps [<xref ref-type="bibr" rid="b2-sensors-10-11556">2</xref>,<xref ref-type="bibr" rid="b29-sensors-10-11556">29</xref>,<xref ref-type="bibr" rid="b18-sensors-10-11556">18</xref>,<xref ref-type="bibr" rid="b28-sensors-10-11556">28</xref>] and neroprene straps [<xref ref-type="bibr" rid="b11-sensors-10-11556">11</xref>] were commonly used for fixing motion sensors on subjects’ bodies [<xref ref-type="bibr" rid="b3-sensors-10-11556">3</xref>,<xref ref-type="bibr" rid="b15-sensors-10-11556">15</xref>]. These tapes and straps are flexible and convenience to use. However, errors caused by skin movement can be significant. Some of the sensors were fixed on aluminum plate [<xref ref-type="bibr" rid="b4-sensors-10-11556">4</xref>,<xref ref-type="bibr" rid="b15-sensors-10-11556">15</xref>,<xref ref-type="bibr" rid="b29-sensors-10-11556">29</xref>,<xref ref-type="bibr" rid="b31-sensors-10-11556">31</xref>,<xref ref-type="bibr" rid="b39-sensors-10-11556">39</xref>] or put inside plastic casing [<xref ref-type="bibr" rid="b6-sensors-10-11556">6</xref>,<xref ref-type="bibr" rid="b25-sensors-10-11556">25</xref>] first before attaching on subject’s bodies. Hard plate and casing can reduce relative skin movement and protect the sensors from damage. However, they are usually heavy and restrict subjects from normal movement. Semi-rigid belt [<xref ref-type="bibr" rid="b27-sensors-10-11556">27</xref>] and exoskeleton [<xref ref-type="bibr" rid="b21-sensors-10-11556">21</xref>] harness were also used for better sensor attachment, but are not convenience for long term ambulatory use. Another important note for fixation of sensor was that we have to ensure the axes of the inertial sensors aligned with the anatomical axes of the segments. Some studies applied anatomical calibration to align sensor’s axes with the axes of the body segment. Calibration devices were adopted in static trial to identify the lines connecting anatomical landmarks [<xref ref-type="bibr" rid="b32-sensors-10-11556">32</xref>]. Static postures were also adopted to calibrate the sensors in a functional approach [<xref ref-type="bibr" rid="b9-sensors-10-11556">9</xref>].</p></sec>
<sec sec-type="discussion">
<label>3.6.</label>
<title>Discussion</title>
<p>Some limitations still exist for lower limb human biomechanics analysis by wearable inertial motion sensors. Firstly, filtering, integration, trigonometry were involved to estimate joint angular kinematics. Therefore, high demand of hardware was needed for data processing, this made a higher cost and larger size for the data processing unit. Most importantly, complicated data processing technique means real time analysis nearly impossible in most of the studies. In some other studies, real time analysis was possible, for example Cutti [<xref ref-type="bibr" rid="b9-sensors-10-11556">9</xref>] and his colleagues can measure real time joint kinematics, however, it was still limited to data collection in clinical setting.</p>
<p>Future development of joint kinematics analysis techniques for wearable inertial sensors should focus simplification of data processing algorithm would be the most challenging part. Batteries lives, fixation method, size of central processing unit were other aspects to be improved. Inertial sensors might replace video cameras and optical motion analysis systems in some human biomechanics studies as data collection could be done outside laboratory settings. The low cost of inertial sensors is obviously another advantage against optical motion analysis systems. Most importantly, it might be applied in ambulation system for real time motion classification, feedback to athletics about sports performance, monitor patients’ daily activities and even act as alarm for activation of protective mechanism when the user was in danger of sports injury.</p></sec></sec>
<sec sec-type="conclusions">
<label>4.</label>
<title>Conclusions</title>
<p>Wearable inertial motion sensors are highly transportable and no stationary units, such as receivers and cameras are needed in data collection, therefore can be used outside laboratory conditions [<xref ref-type="bibr" rid="b2-sensors-10-11556">2</xref>]. Due to the development of micro-electro-mechanical systems (MEMS), the size and power consumption were greatly improved in the design of sensor, making it a good choice for lower limb joint kinematics studies. However, data logging, data processing and fixation method are the areas to be improved in the near future. Simplify data processing algorithm can allow reduction of size and cost of the data processing unit, which allows easy attachment on users for ambulatory purpose. Fixation method which allows freedom of movement and minimizes skin movement is another important aspect.</p></sec></body>
<back>
<ack>
<p>This research project was made possible by resources donated by The Hong Kong Jockey Club Charities Trust.</p></ack>
<ref-list>
<title>References</title>
<ref id="b1-sensors-10-11556"><label>1.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cooper</surname><given-names>G</given-names></name><name><surname>Sheret</surname><given-names>I</given-names></name><name><surname>McMillian</surname><given-names>L</given-names></name><name><surname>Siliverdis</surname><given-names>K</given-names></name><name><surname>Sha</surname><given-names>N</given-names></name><name><surname>Hodgins</surname><given-names>D</given-names></name><name><surname>Kenney</surname><given-names>L</given-names></name><name><surname>Howard</surname><given-names>D</given-names></name></person-group><article-title>Inertial sensor-based knee flexion/extension angle estimation</article-title><source>J Biomech</source><year>2009</year><volume>42</volume><fpage>2678</fpage><lpage>1685</lpage><pub-id pub-id-type="doi">10.1016/j.jbiomech.2009.08.004</pub-id><pub-id pub-id-type="pmid">19782986</pub-id></citation></ref>
<ref id="b2-sensors-10-11556"><label>2.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Coley</surname><given-names>B</given-names></name><name><surname>Najafi</surname><given-names>B</given-names></name><name><surname>Paraschiv-Ionescu</surname><given-names>A</given-names></name><name><surname>Aminian</surname><given-names>K</given-names></name></person-group><article-title>Stair climbing detection during daily physical activity using a miniature gyroscope</article-title><source>Gait Posture</source><year>2005</year><volume>22</volume><fpage>287</fpage><lpage>294</lpage><pub-id pub-id-type="doi">10.1016/j.gaitpost.2004.08.008</pub-id><pub-id pub-id-type="pmid">16274909</pub-id></citation></ref>
<ref id="b3-sensors-10-11556"><label>3.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Willemsen</surname><given-names>ATM</given-names></name><name><surname>Frigo</surname><given-names>C</given-names></name><name><surname>Boom</surname><given-names>HBK</given-names></name></person-group><article-title>Lower extremity angle measurement with accelerometers-error and sensitivity analysis</article-title><source>IEEE Trans Biomed Eng</source><year>1991</year><volume>38</volume><fpage>1186</fpage><lpage>1193</lpage><pub-id pub-id-type="doi">10.1109/10.137284</pub-id><pub-id pub-id-type="pmid">1774080</pub-id></citation></ref>
<ref id="b4-sensors-10-11556"><label>4.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Heyn</surname><given-names>A</given-names></name><name><surname>Mayagoitia</surname><given-names>RE</given-names></name><name><surname>Nene</surname><given-names>AV</given-names></name><name><surname>Veltink</surname><given-names>P</given-names></name></person-group><article-title>The kinematics of the swing phase obtained from accelerometer and gyroscope measurements</article-title><conf-name>Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society</conf-name><conf-loc>Amsterdam, The Netherlands</conf-loc><conf-date>31 October–3 November 1996</conf-date><fpage>463</fpage><lpage>464</lpage></citation></ref>
<ref id="b5-sensors-10-11556"><label>5.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Morris</surname><given-names>JRW</given-names></name></person-group><article-title>Accelerometry—A technique for the measurement of human body movements</article-title><source>J Biomech</source><year>1973</year><volume>6</volume><fpage>729</fpage><lpage>736</lpage><pub-id pub-id-type="doi">10.1016/0021-9290(73)90029-8</pub-id><pub-id pub-id-type="pmid">4757490</pub-id></citation></ref>
<ref id="b6-sensors-10-11556"><label>6.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>O’Donovan</surname><given-names>KJ</given-names></name><name><surname>Kamnik</surname><given-names>R</given-names></name><name><surname>O’Keeffe</surname><given-names>DT</given-names></name><name><surname>Lyons</surname><given-names>GM</given-names></name></person-group><article-title>An inertial and magnetic sensor based technique for joint angle measurement</article-title><source>J Biomech</source><year>2007</year><volume>40</volume><fpage>2604</fpage><lpage>2611</lpage><pub-id pub-id-type="doi">10.1016/j.jbiomech.2006.12.010</pub-id><pub-id pub-id-type="pmid">17346716</pub-id></citation></ref>
<ref id="b7-sensors-10-11556"><label>7.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Favre</surname><given-names>J</given-names></name><name><surname>Jolles</surname><given-names>BM</given-names></name><name><surname>Aissaoui</surname><given-names>R</given-names></name><name><surname>Aminian</surname><given-names>K</given-names></name></person-group><article-title>Ambulatory measurement of 3D knee joint angle</article-title><source>J Biomech</source><year>2008</year><volume>41</volume><fpage>1029</fpage><lpage>1035</lpage><pub-id pub-id-type="doi">10.1016/j.jbiomech.2007.12.003</pub-id><pub-id pub-id-type="pmid">18222459</pub-id></citation></ref>
<ref id="b8-sensors-10-11556"><label>8.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Favre</surname><given-names>J</given-names></name><name><surname>Luthi</surname><given-names>F</given-names></name><name><surname>Jolles</surname><given-names>BM</given-names></name><name><surname>Siegrist</surname><given-names>O</given-names></name><name><surname>Najafi</surname><given-names>B</given-names></name><name><surname>Aminian</surname><given-names>K</given-names></name></person-group><article-title>A new ambulatory system for comparative evaluation of the three-dimensional knee kinematics, applied to anterior cruciate ligament injuries</article-title><source>Knee Surg Sports Traumatol Ar</source><year>2006</year><volume>14</volume><fpage>592</fpage><lpage>604</lpage><pub-id pub-id-type="doi">10.1007/s00167-005-0023-4</pub-id></citation></ref>
<ref id="b9-sensors-10-11556"><label>9.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Cutti</surname><given-names>AG</given-names></name><name><surname>Ferrari</surname><given-names>A</given-names></name><name><surname>Garofalo</surname><given-names>P</given-names></name><name><surname>Raggi</surname><given-names>M</given-names></name><name><surname>Cappello</surname><given-names>A</given-names></name><name><surname>Ferrari</surname><given-names>A</given-names></name></person-group><article-title>Outwalk: A protocol for clinical gait analysis based on inertial and magnetic sensors</article-title><source>Med Biol Eng Comput</source><year>2010</year><volume>48</volume><fpage>17</fpage><lpage>25</lpage><pub-id pub-id-type="doi">10.1007/s11517-009-0545-x</pub-id><pub-id pub-id-type="pmid">19911214</pub-id></citation></ref>
<ref id="b10-sensors-10-11556"><label>10.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Music</surname><given-names>J</given-names></name><name><surname>Kamnik</surname><given-names>R</given-names></name><name><surname>Munih</surname><given-names>M</given-names></name></person-group><article-title>Model based inertial sensing of human body motion kinematics in sit-to-stand movement</article-title><source>Simul Model Pract Theory</source><year>2008</year><volume>16</volume><fpage>933</fpage><lpage>944</lpage><pub-id pub-id-type="doi">10.1016/j.simpat.2008.05.005</pub-id></citation></ref>
<ref id="b11-sensors-10-11556"><label>11.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>van den Noort</surname><given-names>JC</given-names></name><name><surname>Scholtes</surname><given-names>VA</given-names></name><name><surname>Harlaar</surname><given-names>J</given-names></name></person-group><article-title>Evaluation of clinical spasticity assessment in Cerebral palsy using inertial sensors</article-title><source>Gait Posture</source><year>2009</year><volume>30</volume><fpage>138</fpage><lpage>143</lpage><pub-id pub-id-type="doi">10.1016/j.gaitpost.2009.05.011</pub-id><pub-id pub-id-type="pmid">19525113</pub-id></citation></ref>
<ref id="b12-sensors-10-11556"><label>12.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Kawano</surname><given-names>K</given-names></name><name><surname>Kobashi</surname><given-names>S</given-names></name><name><surname>Yagi</surname><given-names>M</given-names></name><name><surname>Kondo</surname><given-names>K</given-names></name><name><surname>Yoshiya</surname><given-names>S</given-names></name><name><surname>Hata</surname><given-names>T</given-names></name></person-group><article-title>Analyzing 3D knee kinematics using accelerometers, gyroscopes and magnetometers</article-title><conf-name>Proceedings of IEEE Conference on Systems Engineering 2007</conf-name><conf-loc>San Antonio, TX, USA</conf-loc><conf-date>16–18 April 2007</conf-date><fpage>1</fpage><lpage>6</lpage></citation></ref>
<ref id="b13-sensors-10-11556"><label>13.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Kawano</surname><given-names>K</given-names></name><name><surname>Kobashi</surname><given-names>S</given-names></name><name><surname>Tsumori</surname><given-names>Y</given-names></name><name><surname>Shibanuma</surname><given-names>N</given-names></name><name><surname>Imawaki</surname><given-names>S</given-names></name><name><surname>Yagi</surname><given-names>M</given-names></name><name><surname>Yoshiya</surname><given-names>S</given-names></name><name><surname>Hata</surname><given-names>Y</given-names></name></person-group><article-title>Evaluation of pivot shift in the anterior cruciate ligament-injured knee using inertial and magnetic sensors</article-title><conf-name>Proceedings of Automation Congress</conf-name><conf-loc>Waikoloa, HI, USA</conf-loc><conf-date>28 September–2 October 2008</conf-date><fpage>1</fpage><lpage>6</lpage></citation></ref>
<ref id="b14-sensors-10-11556"><label>14.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Zijlstra</surname><given-names>A</given-names></name><name><surname>Goosen</surname><given-names>JHM</given-names></name><name><surname>Verheyen</surname><given-names>CCPM</given-names></name><name><surname>Zijlstra</surname><given-names>W</given-names></name></person-group><article-title>A body-fixed-sensor based analysis of compensatory trunk movements during unconstrained walking</article-title><source>Gait Posture</source><year>2008</year><volume>27</volume><fpage>164</fpage><lpage>167</lpage><pub-id pub-id-type="doi">10.1016/j.gaitpost.2007.02.010</pub-id><pub-id pub-id-type="pmid">17433685</pub-id></citation></ref>
<ref id="b15-sensors-10-11556"><label>15.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Andrews</surname><given-names>DM</given-names></name><name><surname>Dowling</surname><given-names>JJ</given-names></name></person-group><article-title>Mechanical modeling of tibial axial accelerations following impulsive heel impact</article-title><source>J Appl Biomech</source><year>2000</year><volume>16</volume><fpage>276</fpage><lpage>288</lpage></citation></ref>
<ref id="b16-sensors-10-11556"><label>16.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Avor</surname><given-names>JK</given-names></name></person-group><article-title>An approach to sensor fusion in medical robots</article-title><conf-name>Proceedings of IEEE 11th International Conference on Rehabilitation Robotics</conf-name><conf-loc>Kyoto, Japan</conf-loc><conf-date>23–26 June 2009</conf-date><fpage>818</fpage><lpage>822</lpage></citation></ref>
<ref id="b17-sensors-10-11556"><label>17.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Chan</surname><given-names>YY</given-names></name><name><surname>Fong</surname><given-names>DTP</given-names></name><name><surname>Chung</surname><given-names>MML</given-names></name><name><surname>Li</surname><given-names>WJ</given-names></name><name><surname>Liao</surname><given-names>WH</given-names></name><name><surname>Yung</surname><given-names>PSH</given-names></name><name><surname>Chan</surname><given-names>KM</given-names></name></person-group><article-title>Identification of ankle sprain motion from common sporting activities by dorsal foot kinematics data</article-title><source>J Biomech</source><year>2010</year><volume>43</volume><fpage>1965</fpage><lpage>1969</lpage><pub-id pub-id-type="doi">10.1016/j.jbiomech.2010.03.014</pub-id><pub-id pub-id-type="pmid">20394934</pub-id></citation></ref>
<ref id="b18-sensors-10-11556"><label>18.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dejnabadi</surname><given-names>H</given-names></name><name><surname>Jolles</surname><given-names>BM</given-names></name><name><surname>Aminian</surname><given-names>K</given-names></name></person-group><article-title>A new approach to accurate measurement of uniaxial joint angles based on a combination of accelerometers and gyroscopes</article-title><source>IEEE Trans Biomed Eng</source><year>2005</year><volume>52</volume><fpage>1478</fpage><lpage>1484</lpage><pub-id pub-id-type="doi">10.1109/TBME.2005.851475</pub-id><pub-id pub-id-type="pmid">16119244</pub-id></citation></ref>
<ref id="b19-sensors-10-11556"><label>19.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Dejnabadi</surname><given-names>H</given-names></name><name><surname>Jolles</surname><given-names>BM</given-names></name><name><surname>Casanova</surname><given-names>E</given-names></name><name><surname>Fua</surname><given-names>P</given-names></name></person-group><article-title>Estimation and visualization of sagittal kinematics of lower limbs orientation using body-fixed sensors</article-title><source>IEEE Trans Biomed Eng</source><year>2006</year><volume>53</volume><fpage>1385</fpage><lpage>1393</lpage><pub-id pub-id-type="doi">10.1109/TBME.2006.873678</pub-id><pub-id pub-id-type="pmid">16830942</pub-id></citation></ref>
<ref id="b20-sensors-10-11556"><label>20.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Ermes</surname><given-names>M</given-names></name><name><surname>Pärkkä</surname><given-names>J</given-names></name></person-group><article-title>Detection of daily activities and sports with wearable sensors in controlled and uncontrolled conditions</article-title><source>IEEE Trans Inf Technol Biomed</source><year>2008</year><volume>12</volume><fpage>20</fpage><lpage>26</lpage><pub-id pub-id-type="doi">10.1109/TITB.2007.899496</pub-id><pub-id pub-id-type="pmid">18270033</pub-id></citation></ref>
<ref id="b21-sensors-10-11556"><label>21.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Favre</surname><given-names>J</given-names></name><name><surname>Aissaoui</surname><given-names>R</given-names></name><name><surname>Jolles</surname><given-names>BM</given-names></name><name><surname>de Guise</surname><given-names>JA</given-names></name><name><surname>Aminian</surname><given-names>K</given-names></name></person-group><article-title>Functional calibration procedure for 3D knee joint angle description using inertial sensors</article-title><source>J Biomech</source><year>2009</year><volume>42</volume><fpage>2330</fpage><lpage>2335</lpage><pub-id pub-id-type="doi">10.1016/j.jbiomech.2009.06.025</pub-id><pub-id pub-id-type="pmid">19665712</pub-id></citation></ref>
<ref id="b22-sensors-10-11556"><label>22.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Findlow</surname><given-names>A</given-names></name><name><surname>Goulermas</surname><given-names>JS</given-names></name><name><surname>Nester</surname><given-names>C</given-names></name><name><surname>Howard</surname><given-names>D</given-names></name><name><surname>Kenney</surname><given-names>LPJ</given-names></name></person-group><article-title>Predicting lower limb joint kinematics using wearable motion sensors</article-title><source>Gait Posture</source><year>2008</year><volume>28</volume><fpage>120</fpage><lpage>126</lpage><pub-id pub-id-type="doi">10.1016/j.gaitpost.2007.11.001</pub-id><pub-id pub-id-type="pmid">18093834</pub-id></citation></ref>
<ref id="b23-sensors-10-11556"><label>23.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Hanlon</surname><given-names>M</given-names></name><name><surname>Anderson</surname><given-names>R</given-names></name></person-group><article-title>Real-time gait event detection using wearable sensors</article-title><source>Gait Posture</source><year>2009</year><volume>30</volume><fpage>523</fpage><lpage>527</lpage><pub-id pub-id-type="doi">10.1016/j.gaitpost.2009.07.128</pub-id><pub-id pub-id-type="pmid">19729307</pub-id></citation></ref>
<ref id="b24-sensors-10-11556"><label>24.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Helot</surname><given-names>R</given-names></name><name><surname>Pissard-Gibollet</surname><given-names>R</given-names></name><name><surname>Espiau</surname><given-names>B</given-names></name><name><surname>Favre-Reguillon</surname><given-names>F</given-names></name></person-group><article-title>Continuous identification of gait phase for robotics and rehabilitation using microsensors</article-title><conf-name>Proceedings of IEEE 12th International Conference on Advanced Robotics</conf-name><conf-loc>Seattle, WA, USA</conf-loc><conf-date>18–20 July 2005</conf-date><fpage>686</fpage><lpage>691</lpage></citation></ref>
<ref id="b25-sensors-10-11556"><label>25.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Kendell</surname><given-names>C</given-names></name></person-group><article-title>Effect of mobility devices on orientation sensors that contain magnetometers</article-title><source>J Rehabil Res Dev</source><year>2009</year><volume>46</volume><fpage>957</fpage><lpage>962</lpage><pub-id pub-id-type="doi">10.1682/JRRD.2008.09.0132</pub-id><pub-id pub-id-type="pmid">20104418</pub-id></citation></ref>
<ref id="b26-sensors-10-11556"><label>26.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Lau</surname><given-names>HY</given-names></name><name><surname>Tong</surname><given-names>KY</given-names></name><name><surname>Zhu</surname><given-names>H</given-names></name></person-group><article-title>Support vector machine for classification of walking conditions of persons after stroke with dropped foot</article-title><source>Hum Movement Sci</source><year>2009</year><volume>28</volume><fpage>504</fpage><lpage>514</lpage><pub-id pub-id-type="doi">10.1016/j.humov.2008.12.003</pub-id></citation></ref>
<ref id="b27-sensors-10-11556"><label>27.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>L’Hemette</surname><given-names>M</given-names></name><name><surname>Savatier</surname><given-names>X</given-names></name><name><surname>Baudry</surname><given-names>L</given-names></name><name><surname>Tourny-Chollet</surname><given-names>C</given-names></name><name><surname>Dujardin</surname><given-names>F</given-names></name></person-group><article-title>A new portable device for assessing locomotor performance</article-title><source>Int J Sports Med</source><year>2008</year><volume>29</volume><fpage>322</fpage><lpage>326</lpage><pub-id pub-id-type="doi">10.1055/s-2007-965336</pub-id><pub-id pub-id-type="pmid">17879888</pub-id></citation></ref>
<ref id="b28-sensors-10-11556"><label>28.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Liu</surname><given-names>T</given-names></name><name><surname>Inoue</surname><given-names>Y</given-names></name><name><surname>Shibata</surname><given-names>K</given-names></name></person-group><article-title>Measurement of muscle motion for improving accuracy of body-mounted motion sensor</article-title><conf-name>Proceedings of IEEE/ASME International Conference on Advanced Intelligent Mechatronics</conf-name><conf-loc>Xi’an, China</conf-loc><conf-date>2–5 July 2008</conf-date><fpage>1325</fpage><lpage>1330</lpage></citation></ref>
<ref id="b29-sensors-10-11556"><label>29.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Liu</surname><given-names>K</given-names></name><name><surname>Liu</surname><given-names>T</given-names></name><name><surname>Shibata</surname><given-names>K</given-names></name><name><surname>Inoue</surname><given-names>Y</given-names></name><name><surname>Zheng</surname><given-names>R</given-names></name></person-group><article-title>Novel approach to ambulatory assessment of human segmental orientation on a wearable sensor system</article-title><source>J Biomech</source><year>2009</year><volume>42</volume><fpage>2747</fpage><lpage>2752</lpage><pub-id pub-id-type="doi">10.1016/j.jbiomech.2009.08.008</pub-id><pub-id pub-id-type="pmid">19748624</pub-id></citation></ref>
<ref id="b30-sensors-10-11556"><label>30.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mamizuka</surname><given-names>N</given-names></name><name><surname>Sakane</surname><given-names>M</given-names></name><name><surname>Kaneoka</surname><given-names>K</given-names></name><name><surname>Hori</surname><given-names>N</given-names></name><name><surname>Ochiai</surname><given-names>N</given-names></name></person-group><article-title>Kinematic quantitation of the patellar tendon reflex using a tri-axial accelerometer</article-title><source>J Biomech</source><year>2007</year><volume>40</volume><fpage>2107</fpage><lpage>2111</lpage><pub-id pub-id-type="doi">10.1016/j.jbiomech.2006.10.003</pub-id><pub-id pub-id-type="pmid">17140585</pub-id></citation></ref>
<ref id="b31-sensors-10-11556"><label>31.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Mayagoitia</surname><given-names>RE</given-names></name><name><surname>Nene</surname><given-names>AV</given-names></name><name><surname>Veltink</surname><given-names>PH</given-names></name></person-group><article-title>Accelerometer and rate gyroscope measurement of kinematics: An inexpensive alternative to optical motion analysis systems</article-title><source>J Biomech</source><year>2002</year><volume>35</volume><fpage>537</fpage><lpage>542</lpage><pub-id pub-id-type="doi">10.1016/S0021-9290(01)00231-7</pub-id><pub-id pub-id-type="pmid">11934425</pub-id></citation></ref>
<ref id="b32-sensors-10-11556"><label>32.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Picermo</surname><given-names>P</given-names></name><name><surname>Cereatti</surname><given-names>A</given-names></name><name><surname>Cappozzo</surname><given-names>A</given-names></name></person-group><article-title>Joint kinematics estimate using wearable inertial and magnetic sensing modules</article-title><source>Gait Posture</source><year>2008</year><volume>28</volume><fpage>588</fpage><lpage>595</lpage><pub-id pub-id-type="doi">10.1016/j.gaitpost.2008.04.003</pub-id><pub-id pub-id-type="pmid">18502130</pub-id></citation></ref>
<ref id="b33-sensors-10-11556"><label>33.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Saber-Sheikh</surname><given-names>K</given-names></name><name><surname>Bryant</surname><given-names>EC</given-names></name><name><surname>Glazzard</surname><given-names>C</given-names></name><name><surname>Hamel</surname><given-names>A</given-names></name><name><surname>Lee</surname><given-names>RYW</given-names></name></person-group><article-title>Feasibility of using inertial sensors to assess human movement</article-title><source>Man Ther</source><year>2010</year><volume>15</volume><fpage>122</fpage><lpage>125</lpage><pub-id pub-id-type="doi">10.1016/j.math.2009.05.009</pub-id><pub-id pub-id-type="pmid">19632882</pub-id></citation></ref>
<ref id="b34-sensors-10-11556"><label>34.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Simcox</surname><given-names>S</given-names></name><name><surname>Parker</surname><given-names>S</given-names></name><name><surname>Davis</surname><given-names>GM</given-names></name><name><surname>Smith</surname><given-names>RW</given-names></name><name><surname>Middleton</surname><given-names>JW</given-names></name></person-group><article-title>Performance of orientation sensors for use with a functional electrical stimulation mobility system</article-title><source>J Biomech</source><year>2005</year><volume>38</volume><fpage>1185</fpage><lpage>1190</lpage><pub-id pub-id-type="doi">10.1016/j.jbiomech.2004.05.026</pub-id><pub-id pub-id-type="pmid">15797599</pub-id></citation></ref>
<ref id="b35-sensors-10-11556"><label>35.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Tong</surname><given-names>K</given-names></name><name><surname>Granat</surname><given-names>MH</given-names></name></person-group><article-title>A practical gait analysis system using gyroscopes</article-title><source>Med Eng Phys</source><year>1999</year><volume>21</volume><fpage>87</fpage><lpage>94</lpage><pub-id pub-id-type="doi">10.1016/S1350-4533(99)00030-2</pub-id><pub-id pub-id-type="pmid">10426508</pub-id></citation></ref>
<ref id="b36-sensors-10-11556"><label>36.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Willemsen</surname><given-names>AT</given-names></name><name><surname>van Alste</surname><given-names>JA</given-names></name><name><surname>Boom</surname><given-names>HB</given-names></name></person-group><article-title>Real-time gait assessment utilizing a new way of accelerometry</article-title><source>J Biomech</source><year>1990</year><volume>23</volume><fpage>859</fpage><lpage>863</lpage><pub-id pub-id-type="doi">10.1016/0021-9290(90)90033-Y</pub-id><pub-id pub-id-type="pmid">2384497</pub-id></citation></ref>
<ref id="b37-sensors-10-11556"><label>37.</label><citation citation-type="confproc"><person-group person-group-type="author"><name><surname>Zhang</surname><given-names>Z</given-names></name><name><surname>Wu</surname><given-names>JK</given-names></name><name><surname>Huang</surname><given-names>Z</given-names></name></person-group><article-title>Gaussian particle filter for tracking hip angle in gait cycles</article-title><conf-name>Proceedings of 10th International Conference on e-health Networking, Applications and Services, 2008</conf-name><conf-loc>Singapore</conf-loc><conf-date>7–9 July 2008</conf-date><fpage>177</fpage><lpage>181</lpage></citation></ref>
<ref id="b38-sensors-10-11556"><label>38.</label><citation citation-type="book"><person-group person-group-type="author"><name><surname>Ahmadi</surname><given-names>A</given-names></name><name><surname>Rowlands</surname><given-names>DD</given-names></name><name><surname>James</surname><given-names>DA</given-names></name></person-group><article-title>Investigating the translational and rotational motion of the swing using accelerometers for athlete skill assessment</article-title><conf-name>Proceedings of 5th IEEE Conference on Sensors</conf-name><conf-loc>Daegu, Korea</conf-loc><conf-date>22–25 October 2006</conf-date><fpage>980</fpage><lpage>983</lpage></citation></ref>
<ref id="b39-sensors-10-11556"><label>39.</label><citation citation-type="journal"><person-group person-group-type="author"><name><surname>Clark</surname><given-names>RA</given-names></name><name><surname>Bartold</surname><given-names>S</given-names></name><name><surname>Bryant</surname><given-names>AL</given-names></name></person-group><article-title>Tibial acceleration variability during consecutive gait cycles is influenced by the menstrual cycle</article-title><source>Clin Biomech</source><year>2010</year><volume>25</volume><fpage>557</fpage><lpage>562</lpage><pub-id pub-id-type="doi">10.1016/j.clinbiomech.2010.03.002</pub-id></citation></ref></ref-list>
<sec sec-type="display-objects">
<title>Figure and Tables</title>
<fig id="f1-sensors-10-11556" position="float">
<label>Figure 1.</label>
<caption>
<p>Research method of this study.</p></caption>
<graphic xlink:href="sensors-10-11556f1.gif"/></fig>
<table-wrap id="t1-sensors-10-11556" position="float">
<label>Table 1.</label>
<caption>
<p>Type of sensors adopted in reviewed studies.</p></caption>
<table frame="box" rules="all">
<thead>
<tr>
<th align="left" valign="middle" rowspan="2"><bold>Source</bold></th>
<th align="center" valign="middle" rowspan="2"><bold>Number of sensor module</bold></th>
<th colspan="3" align="center" valign="middle"><bold>Components of each sensor module</bold></th>
<th align="center" valign="middle" rowspan="2"><bold>Sizes</bold></th>
<th align="center" valign="middle" rowspan="2"><bold>Weight</bold></th>
<th align="center" valign="middle" rowspan="2"><bold>Sampling frequency</bold></th></tr>
<tr>
<th align="center" valign="middle"><bold>Accelerometer</bold></th>
<th align="center" valign="middle"><bold>Gyroscope</bold></th>
<th align="center" valign="middle"><bold>Magnetic Sensor</bold></th></tr></thead>
<tbody>
<tr>
<td align="left" valign="top">Cooper 2009 [<xref ref-type="bibr" rid="b1-sensors-10-11556">1</xref>]</td>
<td align="center" valign="top">1</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">100 Hz</td></tr>
<tr>
<td align="left" valign="top">Coley 2005 [<xref ref-type="bibr" rid="b2-sensors-10-11556">2</xref>]</td>
<td align="center" valign="top">1</td>
<td align="center" valign="top"/>
<td align="center" valign="top">uniaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top">30 × 30 × 30 mm<sup>3</sup></td>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Willemsen 1991 [<xref ref-type="bibr" rid="b3-sensors-10-11556">3</xref>]</td>
<td align="center" valign="top">16</td>
<td align="center" valign="top">uniaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">500 Hz</td></tr>
<tr>
<td align="left" valign="top">Heyn 1996 [<xref ref-type="bibr" rid="b4-sensors-10-11556">4</xref>]</td>
<td align="center" valign="top">8</td>
<td align="center" valign="top">uniaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">100 Hz</td></tr>
<tr>
<td align="left" valign="top">O’Donovan 2007 [<xref ref-type="bibr" rid="b6-sensors-10-11556">6</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">60 × 40 × 24 mm<sup>3</sup></td>
<td align="center" valign="top"/>
<td align="center" valign="top">500 Hz</td></tr>
<tr>
<td align="left" valign="top">Favre 2008 [<xref ref-type="bibr" rid="b7-sensors-10-11556">7</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">30 × 25 × 25 mm<sup>3</sup></td>
<td align="center" valign="top"/>
<td align="center" valign="top">200 Hz</td></tr>
<tr>
<td align="left" valign="top">Favre 2006 [<xref ref-type="bibr" rid="b8-sensors-10-11556">8</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Cutti [<xref ref-type="bibr" rid="b9-sensors-10-11556">9</xref>]</td>
<td align="center" valign="top">10</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">39 × 54 × 28 mm<sup>3</sup></td>
<td align="center" valign="top">38 g</td>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Van den Noort 2009 [<xref ref-type="bibr" rid="b11-sensors-10-11556">11</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">100 Hz</td></tr>
<tr>
<td align="left" valign="top">Kawano 2007 [<xref ref-type="bibr" rid="b12-sensors-10-11556">12</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">53 × 38 × 21 mm<sup>3</sup></td>
<td align="center" valign="top"/>
<td align="center" valign="top">100 Hz</td></tr>
<tr>
<td align="left" valign="top">Kawano 2008 [<xref ref-type="bibr" rid="b13-sensors-10-11556">13</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">53 × 38 × 21 mm<sup>3</sup></td>
<td align="center" valign="top">30 g</td>
<td align="center" valign="top">200 Hz</td></tr>
<tr>
<td align="left" valign="top">Zijlstra 2008 [<xref ref-type="bibr" rid="b14-sensors-10-11556">14</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top">64 × 62 × 26 mm<sup>3</sup></td>
<td align="center" valign="top">150 g</td>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Andrews 2000 [<xref ref-type="bibr" rid="b15-sensors-10-11556">15</xref>]</td>
<td align="center" valign="top">1</td>
<td align="center" valign="top">uniaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">18.2 g</td>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Avor 2009 [<xref ref-type="bibr" rid="b16-sensors-10-11556">16</xref>]</td>
<td align="center" valign="top">4</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Chan 2010 [<xref ref-type="bibr" rid="b17-sensors-10-11556">17</xref>]</td>
<td align="center" valign="top">1</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top">20 × 18 × 6 mm<sup>3</sup></td>
<td align="center" valign="top"/>
<td align="center" valign="top">500 Hz</td></tr>
<tr>
<td align="left" valign="top">Dejnabadi 2005 [<xref ref-type="bibr" rid="b18-sensors-10-11556">18</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">biaxial</td>
<td align="center" valign="top">uniaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top">20 × 20 × 10 mm<sup>3</sup></td>
<td align="center" valign="top"/>
<td align="center" valign="top">200 Hz</td></tr>
<tr>
<td align="left" valign="top">Dejnabadi 2006 [<xref ref-type="bibr" rid="b19-sensors-10-11556">19</xref>]</td>
<td align="center" valign="top">4</td>
<td align="center" valign="top">biaxial</td>
<td align="center" valign="top">uniaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top">20 × 20 × 10 mm<sup>3</sup></td>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Ermes 2008 [<xref ref-type="bibr" rid="b20-sensors-10-11556">20</xref>]</td>
<td align="center" valign="top">3</td>
<td align="center" valign="top">2 triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top">1 triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">20 Hz</td></tr>
<tr>
<td align="left" valign="top">Favre 2009 [<xref ref-type="bibr" rid="b21-sensors-10-11556">21</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">240 Hz</td></tr>
<tr>
<td align="left" valign="top">Findlow 2008 [<xref ref-type="bibr" rid="b22-sensors-10-11556">22</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top">54 × 39 × 28 mm<sup>3</sup></td>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Hanlon 2009 [<xref ref-type="bibr" rid="b23-sensors-10-11556">23</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">biaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">200 Hz</td></tr>
<tr>
<td align="left" valign="top">Helot 2005 [<xref ref-type="bibr" rid="b24-sensors-10-11556">24</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">100 Hz</td></tr>
<tr>
<td align="left" valign="top">Kendell 2009 [<xref ref-type="bibr" rid="b25-sensors-10-11556">25</xref>]</td>
<td align="center" valign="top">3</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Lau 2009 [<xref ref-type="bibr" rid="b26-sensors-10-11556">26</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">biaxial</td>
<td align="center" valign="top">uniaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top">20 × 10 × 10 mm<sup>3</sup></td>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">L’Hemette 2008 [<xref ref-type="bibr" rid="b27-sensors-10-11556">27</xref>]</td>
<td align="center" valign="top">1</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">700 g</td>
<td align="center" valign="top">100 Hz</td></tr>
<tr>
<td align="left" valign="top">Liu 2008 [<xref ref-type="bibr" rid="b28-sensors-10-11556">28</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Liu 2009 [<xref ref-type="bibr" rid="b29-sensors-10-11556">29</xref>]</td>
<td align="center" valign="top">3</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Mamizuka 2007 [<xref ref-type="bibr" rid="b30-sensors-10-11556">30</xref>]</td>
<td align="center" valign="top">1</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Mayagoitia 2002 [<xref ref-type="bibr" rid="b31-sensors-10-11556">31</xref>]</td>
<td align="center" valign="top">8</td>
<td align="center" valign="top">uniaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">100 Hz</td></tr>
<tr>
<td align="left" valign="top">Picemo [<xref ref-type="bibr" rid="b32-sensors-10-11556">32</xref>]</td>
<td align="center" valign="top">4</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Saber-Sheikh 2010 [<xref ref-type="bibr" rid="b33-sensors-10-11556">33</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top">53 × 38 × 21 mm<sup>3</sup></td>
<td align="center" valign="top">30 g</td>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Simcox 2005 [<xref ref-type="bibr" rid="b34-sensors-10-11556">34</xref>]</td>
<td align="center" valign="top">3</td>
<td align="center" valign="top">2 biaxial</td>
<td align="center" valign="top">1 uniaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top">70 × 50 × 25 mm<sup>3</sup></td>
<td align="center" valign="top"/>
<td align="center" valign="top">800 Hz</td></tr>
<tr>
<td align="left" valign="top">Tong 1999 [<xref ref-type="bibr" rid="b35-sensors-10-11556">35</xref>]</td>
<td align="center" valign="top">2</td>
<td align="center" valign="top"/>
<td align="center" valign="top">uniaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top">20 × 10 × 7.2 mm<sup>3</sup></td>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Willemsen 1990 [<xref ref-type="bibr" rid="b36-sensors-10-11556">36</xref>]</td>
<td align="center" valign="top">16</td>
<td align="center" valign="top">uniaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">500 Hz</td></tr>
<tr>
<td align="left" valign="top">Zhang 2008 [<xref ref-type="bibr" rid="b37-sensors-10-11556">37</xref>]</td>
<td align="center" valign="top">1</td>
<td align="center" valign="top">biaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr>
<tr>
<td align="left" valign="top">Ahmadi 2006 [<xref ref-type="bibr" rid="b38-sensors-10-11556">38</xref>]</td>
<td align="center" valign="top">3</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top">500 Hz</td></tr>
<tr>
<td align="left" valign="top">Clark 2010 [<xref ref-type="bibr" rid="b39-sensors-10-11556">39</xref>]</td>
<td align="center" valign="top">1</td>
<td align="center" valign="top">triaxial</td>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/>
<td align="center" valign="top"/></tr></tbody></table></table-wrap>
<table-wrap id="t2-sensors-10-11556" position="float">
<label>Table 2.</label>
<caption>
<p>Motions involved in reviewed studies.</p></caption>
<table frame="box" rules="all">
<thead>
<tr>
<th align="left" valign="top"><bold>Source</bold></th>
<th align="left" valign="top"><bold>Tested motions</bold></th></tr></thead>
<tbody>
<tr>
<td align="left" valign="middle">Cooper 2009 [<xref ref-type="bibr" rid="b1-sensors-10-11556">1</xref>]</td>
<td align="left" valign="middle">Walking at five speed from 1–5 mi/h</td></tr>
<tr>
<td align="left" valign="middle">Coley 2005 [<xref ref-type="bibr" rid="b2-sensors-10-11556">2</xref>]</td>
<td align="left" valign="middle">Walking, stair climbing</td></tr>
<tr>
<td align="left" valign="middle">Heyn 1996[<xref ref-type="bibr" rid="b4-sensors-10-11556">4</xref>]</td>
<td align="left" valign="middle">Walking</td></tr>
<tr>
<td align="left" valign="middle">O’Donovan 2007 [<xref ref-type="bibr" rid="b6-sensors-10-11556">6</xref>]</td>
<td align="left" valign="middle">Heel and toe rise foot pumps, knee flexion and extension, clockwise and anti-clockwise ankle rotation, lateral and medial foot rotation, eversion and inversion, ambulation</td></tr>
<tr>
<td align="left" valign="middle">Favre 2008 [<xref ref-type="bibr" rid="b7-sensors-10-11556">7</xref>]</td>
<td align="left" valign="middle">Knee abduction and adduction, 30 m flat walking</td></tr>
<tr>
<td align="left" valign="middle">Favre 2006 [<xref ref-type="bibr" rid="b8-sensors-10-11556">8</xref>]</td>
<td align="left" valign="middle">Walking</td></tr>
<tr>
<td align="left" valign="middle">Cutti 2010 [<xref ref-type="bibr" rid="b9-sensors-10-11556">9</xref>]</td>
<td align="left" valign="middle">Walking</td></tr>
<tr>
<td align="left" valign="middle">Music 2008 [<xref ref-type="bibr" rid="b10-sensors-10-11556">10</xref>]</td>
<td align="left" valign="middle">Sit to stand movement</td></tr>
<tr>
<td align="left" valign="middle">Van den Noort 2009 [<xref ref-type="bibr" rid="b11-sensors-10-11556">11</xref>]</td>
<td align="left" valign="middle">Clinical assessment of knee joint</td></tr>
<tr>
<td align="left" valign="middle">Zijlstra 2008 [<xref ref-type="bibr" rid="b14-sensors-10-11556">14</xref>]</td>
<td align="left" valign="middle">Walking</td></tr>
<tr>
<td align="left" valign="middle">Andrews 2000 [<xref ref-type="bibr" rid="b15-sensors-10-11556">15</xref>]</td>
<td align="left" valign="middle">Landing from a 5 cm fall</td></tr>
<tr>
<td align="left" valign="middle">Avor 2009 [<xref ref-type="bibr" rid="b16-sensors-10-11556">16</xref>]</td>
<td align="left" valign="middle">Running on treadmill on three different speed</td></tr>
<tr>
<td align="left" valign="middle">Chan 2010 [<xref ref-type="bibr" rid="b17-sensors-10-11556">17</xref>]</td>
<td align="left" valign="middle">Walking, running, jumping, walking downstairs, cutting, simulated ankle sprain</td></tr>
<tr>
<td align="left" valign="middle">Dejnabadi 2005 [<xref ref-type="bibr" rid="b18-sensors-10-11556">18</xref>]</td>
<td align="left" valign="middle">Walking level at 3 km/h</td></tr>
<tr>
<td align="left" valign="middle">Ermes 2008 [<xref ref-type="bibr" rid="b20-sensors-10-11556">20</xref>]</td>
<td align="left" valign="middle">Walking, running, rowing, cycling</td></tr>
<tr>
<td align="left" valign="middle">Favre 2009 [<xref ref-type="bibr" rid="b21-sensors-10-11556">21</xref>]</td>
<td align="left" valign="middle">Walking</td></tr>
<tr>
<td align="left" valign="middle">Findlow 2008 [<xref ref-type="bibr" rid="b22-sensors-10-11556">22</xref>]</td>
<td align="left" valign="middle">Walking at self-selected pace</td></tr>
<tr>
<td align="left" valign="top">Hanlon 2009 [<xref ref-type="bibr" rid="b23-sensors-10-11556">23</xref>]</td>
<td align="left" valign="top">Walking</td></tr>
<tr>
<td align="left" valign="top">Helot 2005 [<xref ref-type="bibr" rid="b24-sensors-10-11556">24</xref>]</td>
<td align="left" valign="top">Walking</td></tr>
<tr>
<td align="left" valign="top">Lau 2009 [<xref ref-type="bibr" rid="b26-sensors-10-11556">26</xref>]</td>
<td align="left" valign="top">Walking level, upslope down slope, downstairs, upstairs</td></tr>
<tr>
<td align="left" valign="top">L’Hemette 2008[<xref ref-type="bibr" rid="b27-sensors-10-11556">27</xref>]</td>
<td align="left" valign="top">Walking</td></tr>
<tr>
<td align="left" valign="top">Liu 2009 [<xref ref-type="bibr" rid="b29-sensors-10-11556">29</xref>]</td>
<td align="left" valign="top">Walking at self-selected slow, normal and fast speeds</td></tr>
<tr>
<td align="left" valign="top">Mamizuka 2007 [<xref ref-type="bibr" rid="b30-sensors-10-11556">30</xref>]</td>
<td align="left" valign="top">Knee flexion and extension</td></tr>
<tr>
<td align="left" valign="top">Mayagoitia 2002 [<xref ref-type="bibr" rid="b31-sensors-10-11556">31</xref>]</td>
<td align="left" valign="top">Walking at 1.4 km/h, 2.1 km/h, 2.7 km/h, 3.6 km/h and 4.6 km/h</td></tr>
<tr>
<td align="left" valign="top">Picemo 2008 [<xref ref-type="bibr" rid="b32-sensors-10-11556">32</xref>]</td>
<td align="left" valign="top">Walking</td></tr>
<tr>
<td align="left" valign="top">Saber-Sheikh 2010 [<xref ref-type="bibr" rid="b33-sensors-10-11556">33</xref>]</td>
<td align="left" valign="top">Walking</td></tr>
<tr>
<td align="left" valign="top">Simcox 2005 [<xref ref-type="bibr" rid="b34-sensors-10-11556">34</xref>]</td>
<td align="left" valign="top">Sit-stand-sit, walking</td></tr>
<tr>
<td align="left" valign="top">Willemsen 1990 [<xref ref-type="bibr" rid="b36-sensors-10-11556">36</xref>]</td>
<td align="left" valign="top">Walking</td></tr>
<tr>
<td align="left" valign="top">Zhang 2008 [<xref ref-type="bibr" rid="b37-sensors-10-11556">37</xref>]</td>
<td align="left" valign="top">Walking</td></tr>
<tr>
<td align="left" valign="top">Ahmadi 2006 [<xref ref-type="bibr" rid="b38-sensors-10-11556">38</xref>]</td>
<td align="left" valign="top">Tennis serving</td></tr>
<tr>
<td align="left" valign="top">Clark 2010 [<xref ref-type="bibr" rid="b39-sensors-10-11556">39</xref>]</td>
<td align="left" valign="top">Running on treadmill (10 km/h)</td></tr></tbody></table></table-wrap></sec></back></article>