Next Article in Journal
Evolution and Biological Evaluation of Matrinic Derivatives with Amantadine Fragments As New Anti-Influenza Virus Agents
Next Article in Special Issue
A Novel Modified Electrode for Detection of the Food Colorant Sunset Yellow Based on Nanohybrid of MnO2 Nanorods-Decorated Electrochemically Reduced Graphene Oxide
Previous Article in Journal
Prediction of Protein Subcellular Localization Based on Fusion of Multi-view Features
Previous Article in Special Issue
All Solid-State Poly (Vinyl Chloride) Membrane Potentiometric Sensor Integrated with Nano-Beads Imprinted Polymers for Sensitive and Rapid Detection of Bispyribac Herbicide as Organic Pollutant
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Single-Piece Solid Contact Cu2+-Selective Electrodes Based on a Synthesized Macrocyclic Calix[4]arene Derivative as a Neutral Carrier Ionophore

by
Abd El-Galil E. Amr
1,2,*,
Mohamed A. Al-Omar
1,
Ayman H. Kamel
3,* and
Elsayed A. Elsayed
4,5
1
Pharmaceutical Chemistry Department, Drug Exploration & Development Chair (DEDC), College of Pharmacy, King Saud University, Riyadh 11451, Saudi Arabia
2
Applied Organic Chemistry Department, National Research Centre, Dokki, Cairo 12622, Egypt
3
Chemistry Department, Faculty of Science, Ain Shams University, Abbasia, Cairo 11566, Egypt
4
Zoology Department, Bioproducts Research Chair, Faculty of Science, King Saud University, Riyadh 11451, Saudi Arabia
5
Chemistry of Natural and Microbial Products Department, National Research Centre, Dokki, Cairo 12622, Egypt
*
Authors to whom correspondence should be addressed.
Molecules 2019, 24(5), 920; https://doi.org/10.3390/molecules24050920
Submission received: 31 January 2019 / Revised: 12 February 2019 / Accepted: 20 February 2019 / Published: 6 March 2019
(This article belongs to the Special Issue Analysis of Residues in Food and Environment)

Abstract

:
Herein, a facile route leading to good single-walled carbon nanotubes (SWCNT) dispersion or poly (3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT/PSS) based single-piece nanocomposite membrane is proposed for trace determination of Cu2+ ions. The single-piece solid contact Cu2+-selective electrodes were prepared after drop casting the membrane mixture on the glassy-carbon substrates. The prepared potentiometric sensors revealed a Nernstian response slope of 27.8 ± 0.3 and 28.1 ± 0.4 mV/decade over the linearity range 1.0 × 10−3 to 2.0 × 10−9 and 1.0 × 10−3 to 1.0 × 10−9 M with detection limits of 5.4 × 10−10 and 5.0 × 10−10 M for sensors based on SWCNTs and PEDOT/PSS, respectively. Excellent long-term potential stability and high hydrophobicity of the nanocomposite membrane are recorded for the prepared sensors due to the inherent high capacitance of SWCNT used as a solid contact material. The sensors exhibited high selectivity for Cu2+ ions at pH 4.5 over other common ions. The sensors were applied for Cu2+ assessment in tap water and different tea samples. The proposed sensors were robust, reliable and considered as appealing sensors for copper (II) detection in different complex matrices.

Graphical Abstract

1. Introduction

It is important for environmental protection, food and agricultural chemistry to monitor and quantify metal ions in the trace level. Copper is widely used in industry, agriculture and for domestic purposes. Therefore, it can be considered as one of the most widely distributed elements in industrialized countries. Copper has a major role in numerous biological processes such as blood formation and the functioning of various enzymes [1,2]. The maximum tolerable level for copper is 2.0 mg/L, and an excessive intake of this element manifests certain diseases in humans such as Menkes syndrome and Wilson’s disease [3,4]. Consequently, it is necessary to find an accurate and reliable analytical method for trace-level determination of copper. This has become imperative from the viewpoint of its utility as well as its toxicity.
Several analytical techniques have been reported for copper determination [5,6,7,8,9,10,11,12,13,14,15,16,17,18]. Among these, Cu2+-selective electrodes integrated in potentiometric systems, especially the solid contact ion-selective electrodes (SC-ISEs), draw a lot of attraction owing to their portability, disposability and low-cost [19,20,21,22]. These potentiometric type sensors have wide applications in many fields, such as medical diagnosis, process control and environmental monitoring [23,24,25]. Coated wire electrode (CWE) is the original part of SC-ISE in which the ion-selective membrane (ISM) is directly coated on a conductive substrate [26]. CWEs have limited applications due to their poor reproducibility and potential instability. These are caused by the blocked (low capacity) interface between the electronic conductor and the ionically conducting ISM [27]. This ill-defined interface between the ISM and the conducting substrate leads to potential drift. Therefore, much work has focused on developing ion-to-electron transducing layers to form an ion exchange equilibrium-based stable potential at the ISM/SC interface and phase boundary potential at the SC/electronic conductor interface. This work includes conducting polymers (CPs) [28] and nano-structured carbon materials [29,30,31,32].
Several reports focus on using solid contact materials-based solid-contact Cu2+-ISE. One is based on the use of 1-ethyl-3-methyl imidazolium chloride as an ionic liquid doped with the ionophore [33]. Nano-structured carbon materials are also used as solid contact materials-based solid-contact Cu2+-ISE such as carboxylic multi-walled carbon nanotubes [34], multi-walled carbon nanotubes (MWCNT) [35], single-walled carbon nanotubes (MWCNT) [36] and graphen (GR) and grapheme oxide (GO) [37]. Single-piece solid-contact Cu2+-ISEs have different advantages such as ease of miniaturization, simplicity, stability and disposability.
In this work, a facile approach for the fabrication of single-piece Cu2+-selective nanocomposite membrane based on two different solid contact materials, namely surfactant-free and well-dispersed single walled-carbon nanotube (SWCNT) and poly (3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT/PSS) are proposed here. The potentiometric performance characteristics of the single-piece Cu2+-ISE nanocomposite membrane were studied as well as the sensing conditions. The practical feasibility of the proposed sensors was evaluated in copper determination in tap water and different tea samples collected from the local market.

2. Results and Discussion

2.1. SWCNTs Versus PEDOT/PSS

In this work, we employed a facile and simple method for fabrication of robust solid-contact ISEs using a synthesized macrocyclic calix[4]arene derivative as copper Ionophore (Figure 1) and SWCNTs and PEDOT/PSS as solid-contact transducers. The single-piece solid contact Cu2+-ISEs were prepared via one-step drop casting the ultra-sonicated suspension mixture on GC surface electrodes. The principle of ion-to-electron transduction in SWCNTs is based on the high charge transfer of carbon nanotubes. SWCNTs are characterized by their high surface/volume ratios. This contributes to enlarging the contact area between the polymeric sensing membrane and the nanotubes. As such, it will minimize the resistance at this interface. The high influence of the surrounding chemical environment on the conductance of carbon nanotubes makes the nanotubes very sensitive to the phase-boundary potential changes generated at the interface ion-selective membrane-test solution. The charge transfer process between the ionic conducting membrane and the electronically conducting wire takes place without producing voltage instabilities. SWCNTs are also characterized by their high hydrophobicity. This may be the reason why a significant water layer is not detected in the ion-selective membrane or the transducer layer interface.
Poly (3,4-ethylenedioxythiophene) is known as one of the most stable conducting polymers available today [38]. The principle of ion-to-electron transduction in PEDOT as a solid-contact material is directly related to the redox capacitance of this material. PEDOT as a conducting polymer is characterized by high stability, high ionic mobility and a high charge transfer rate, as well as good adhesion to the membrane material and electrode substrate. These characteristics make it a good material for a solid contact of ISEs.
To evaluate the potential stability in the proposed sensors using either PEDOT/PSS or SWCNTs as solid contact materials, constant current chronopotentiometry was used according to Bobacka’s protocol [39]. As can be seen from the chronopotentiograms shown in Figure 2, the bulk membrane resistances together with contact resistance between the ISM and the underlying conductor (Rbc) were found to be 0.2 ± 0.03, 0.11 ± 0.04 and 0.10 ± 0.02 MΩ, for GC/Cu2+, GC/PEDOT/PSS/Cu2+ and GC/SWCNTs/Cu2+-ISEs, respectively. For GC/Cu2+-ISEs (i.e., CWE), the potential drift was calculated to be 75 ± 3.2 µV s−1. Nevertheless, GC/PEDOT/PSS/Cu2+ and GC/SWCNTs/Cu2+-ISEs a negligible potential drift was observed, and a much smaller potential drift value of 30.1 ± 2.5 µV s−1 (n = 3) and 16.6 ± 1.2 µV s−1 (n = 3) was recorded, respectively. As mentioned, the potential stability of SWCNTs is much higher than of PEDOT/PSS. This is confirmed by the measured capacitance for both. The capacitances of GC/Cu2+, GC/PEDOT/PSS/Cu2+ and GC/SWCNTs/Cu2+-ISEs were calculated to be 13.3 ± 0.7, 33.3 ± 1.3 and 60.2 ± 0.2 µF, respectively.

2.2. Response Characteristics of the Solid-Contact Cu2+-ISEs

Five different sensor assemblies for each membrane type were tested over a period of 3 months. All potentiometric characteristics were shown in Table 1. The potentiometric response of the sensors at pH 4 revealed Nernstian slopes of 28.0 ± 0.4, 28.1 ± 0.4, and 27.8 ± 0.3 mV/decade over the linear concentration range of 1.0 × 10−9 to 1.0 × 10−3, 2.0 × 10−9 to 1.0 × 10−3 and 1.0 × 10−9 to 1.0 × 10−3 M with a detection limits 5.0 × 10−10, 5.4 × 10−10 and 5.0 × 10−10 for GC/Cu2+, GC/PEDOT/PSS/Cu2+ and GC/SWCNTs/Cu2+- ISEs, respectively (Figure 3).
The dependence of electrode potential on pH was investigated using 1 × 10−4 M Cu2+ solution over the pH range 2.0–7.0. The pH was adjusted using HNO3 or LiOH solutions. According to the obtained results, the potential of proposed sensors is almost constant over the pH range 3–6.5 as shown in Table 1. At pH < 6.5, the potential declined due to the formation of Cu(OH)2. At pH < 3.0, the potential begins to increase due to the acidic media effect, which may be attributed to either the ionic additive in the membrane phase or the ionophore properties or both.
Sensor selectivity is one of the most important parameters for any potentiometric sensor. Selectivity coefficient values were calculated using the separate solution method (SSM) to eliminate the influence of the inherent sensitivity limit on the ISE response toward the discriminated ions [40]. As shown in Table 2, the sensors having SWCNTs in the membrane are characterized by better selectivity than those containing PEDOT/PSS. This may be attributed to the contribution of ionic exchange property of both [PEDOT]+ and [PSS] ions.
Electrode potential reproducibility was also investigated. Six electrodes from each membrane type were taken and the measurements were conducted in 10−2 M Cu2+ solution with pH adjusted to 4.0 with HNO3 as the background. The mean value of the slope for each membrane type sensor is 28.2 ± 0.7, 27.8 ± 0.3 and 28.1 ± 0.4 mV/decade, and the standard deviation is 1.3, 0.7 and 0.8 mM for GC/Cu2+, GC/PEDOT/PSS/Cu2+ and GC/SWCNTs/Cu2+-ISEs, respectively.

2.3. Water Film Test of the Electrode Potential

Formation of water film between the Cu2+-selective membrane and the solid contact material was investigated. In this test, the ISEs were first conditioned in a solution of the primary ions and then the sample was replaced with a solution of the background electrolyte. A control experiment was performed by using the CWE. As shown in Figure 4, a negative EMF change of ~115 mV is noticed for all ISEs upon replacing 1.0 × 10−5 M Cu2+ solution with the electrolytic background solution. After 3 h, a positive potential drift is recorded for the CWE indicating the formation of water layer between the electrode membranes and conducting substrate. For sensors based on PEDOT and SWCNTs as solid contact materials, they exhibit a stable potential response and confirm the absence of a water layer. From these results, we can demonstrate that the undesirable water layer can be successfully eliminated by the intermediate solid contact layer of the proposed sensors. This is can be attributed to the high hydrophobicity of the PEDOT and SWCNTs based transducer layer, which may lead to the absence of the water film.
The long-term response of the proposed GC/SWCNTsCu2+ and GC/PEDOT/PSS/Cu2+-ISEs is also tested. When not in use, these fabricated sensors were all conditioned in 1.0 × 10−9 M Cu2+ solution. No noticeable change in the response slopes and detection limits was observed within 3 months. After three months, the detection limit changed about half an order of magnitude. The results indicated the absence of the water films. The robust and reliable single-piece Cu2+-ISEs are promising for applications in many fields of contemporary research.

2.4. Sensors’ Applicability

To test the applicability of the sensors, they were introduced to assess copper content in collected tap water samples and tea samples collected from the local market. As shown in Table 3, it can be seen that the recoveries of tap water samples vary from 93.3% to 106.6% and the data obtained by the proposed electrode agree well with those obtained by the AAS method. This confirms that the proposed potentiometric sensor has a promising potential for real sample analysis and feasible for assessing Cu2+ ions in polluted water samples.
The sensor was also used for the direct assay of copper content in tea infusion samples collected from the local market. The obtained results were compared with AAS method for the evaluation of the accuracy. All measurements were carried out in triplicate. The results obtained are shown in Table 4. The data obtained showed that potentiometric measurements of Cu2+ ions in tea samples were in good agreement with those obtained by the AAS method. For the statistical treatment of data; Student t test was performed at 95% confidence level. For all of the tea samples the calculated t values at 95% confidence levels are smaller than the critical t value (2.78). According to this, no significant differences between the performances of the two methods and the proposed sensor. The proposed sensors show a good applicability in the assessment of Copper content in real samples.
To explore the novelty of this work, comparison of the proposed sensors with other solid-contact Cu2+-ISEs previously reported is also given in Table 5. The table clearly indicated good enhancement in the behavior of the proposed copper electrode in terms of the detection limit and linear range [33,35,36,37,41,42,43,44], slope [34,44] and selectivity [33,34,42].

3. Materials and Methods

3.1. Reagents

Copper ionophore (Figure 1) was prepared and elucidated according to literature procedures [45]. High molecular weight poly(vinyl chloride) (PVC), tetradodecylammonium tetrakis (4-chlorophenyl) borate (ETH 500), sodium tetrakis [3,5 bis (trifluoromethyl) phenyl] borate (NaTFPB), 2-nitrophenyl octyl ether (o-NPOE) and tetrahydrofuran (THF) were all purchased from Sigma-Aldrich (Gillingham, Dorset, UK). SWCNTs obtained from XFnano Materials Tech Co., Ltd. (Nanjing, China) with no further purification and modification. Copper nitrate (Cu(NO3)2) and other salts were all obtained from Sigma-Aldrich, and corresponding solutions were prepared in freshly deionized water (DI water, resistance 18.2 MΩ cm, Millipore, Washington, WA, USA). Other chemicals used in this study were all of analytical reagent grade and used as received.
A stock solution of 0.01 M Cu2+ was prepared by dissolving Cu(NO3)2 in deionized water and then diluted to various concentrations of working solutions with deionized water prior to measurements.

3.2. Apparatus

All measurements of electromotive force (EMF) were performed at ambient temperature using an Orion pH/mV meter (model SA 720, Cambridge, MA, USA) in the galvanic cell: Ag/AgCl/KCl (sat)//0.1 M LiOAc/sample solution/ISE membrane containing SC material/GCE. Selectivity coefficients were determined by the separate solution method [39]. Chronopotentiometry tests were done using a conventional three electrode system including an ISE working electrode, Ag/AgCl (3 M) as the reference electrode and a Pt wire as the counter electrode. Chronopotentiometric measurements were carried out on the proposed sensors in 10−2 M Cu2+ by applying a constant current of ±1 nA for 60 s, respectively.

3.3. Electrode Fabrication

The ion-selective sensing nanocomposite membrane cocktail (total mass 360 mg in 2.5 mL THF) was prepared by dissolving copper ionophore (1 wt%,), NaTFPB (0.5 wt%), ETH 500 (1 wt%), o-NPOE (49 wt%), and PVC (48.5 wt%) together with 1 mg of SWCNT in 1 mL THF or 20 µL of PEDOT/PSS solution. The cocktail was sonicated for at least 30 min with a power of 200 W to obtain a uniform solution. The sensors were fabricated as follows: Glassy carbon electrodes (GCE) were polished with 0.3 µm alumina slurries, sonicated with ethanol and de-ionized water separately, then dried under nitrogen. The cleaned electrodes were then tightly inserted into a piece of matched PVC tube (1 cm long, 5 mm i.d. and 8 mm o.d.) at the distal end.
A 200 μL of the membrane cocktail was dropped cast on the GC disks evenly and the solvent was evaporated thoroughly at ambient temperature. A uniform composite layer with strong adhesion to the GCE surface was obtained. The coated wire electrodes (CWEs) were prepared by the similar steps without the addition of solid contacts. The Cu2+-selective electrodes were firstly conditioned in 10−3 M Cu2+ ion solution for 1 day and then in 10−9 M Cu2+ for 2 days. The pH of the test solutions was adjusted by HNO3 at pH 4. This pH of the tested copper nitrate solution makes Cu2+ the predominating form of copper.

3.4. Analytical Application

The sensors were introduced to determine copper content in different samples. Different tap water samples were collected and analyzed by the proposed GC/SWCNT Cu2+-ISEs to analyze the Cu2+ concentration. The samples were first boiled for about 10 min to remove excess chlorine present and adjusted with HNO3 till the pH of the sample reaches 3.8. A comparison between the proposed sensor and the atomic absorption spectroscopy (AAS) method was performed.
The sensors were also used for the direct assay of copper content in tea infusion samples collected from the local market. About a 100 gm portion of the tea samples were introduced into a porcelain dish and ashed at 300 °C for 1 h then heated in a muffle furnace at 1000 °C for an extra 2 h. After cooling, 2 mL of concentrated HNO3 and 2 mL of concentrated HCl were added and the content was heated until near dryness. The residue was dissolved by deionized water and completed to the mark in 50 mL measuring flask. A 10.0-mL aliquot of the filtrate was transferred into a 30-mL beaker and the copper content was determined using the proposed potetiometric method.

4. Conclusions

In this work, an all-solid-state potentiometric sensor for determination of copper has been proposed. It is based on the synthesized macrocyclic calix[4]arene derivative as the selective receptor and the SWCNTs and PEDOT/PSS as the solid contact materials on glassy carbon substrate. The solid-contact material was dispersed into o-NPOE-plasticized membrane by ultrasonication. The simple and generally applicable one-step fabrication yielded a single piece Cu2+-ISEs. The sensors revealed low detection limit of 5.4 × 10−10 and 5.0 × 10−10 M and a fast response time of <10 s for GC/SWCNTs-Cu2+-ISEs and GC/PEDOT/PSS/Cu2+-ISEs, respectively. The addition of either SWCNTs or PEDOT/PSS into the Cu2+-selective membrane enhanced the hydrophobicity and capacitance with considerable potential stability which was tested by electrochemical impedance spectroscopy (EIS) and constant-current chronopotentiometry techniques. In addition, a water layer test was also conducted to confirm the absence of water films between the ion-selective membrane and the electron conductor. The proposed single-piece Cu2+-ISEs were successfully applied for copper quantification in both tea and tap water samples. The proposed sensors offered good advantages such as simplicity in fabrication, easy operation, robustness, stability and low cost.

Author Contributions

Conceptualization, A.H.K. and A.E.-G.E.A.; Methodology, A.H.K. and A.E.-G.E.A.; Software, E.A.E.; Validation, A.H.K., A.E.-G.E.A. and E.A.E.; Formal Analysis, A.H.K.; Investigation, A.H.K. and A.E.-G.E.A.; Resources, M.A.A.-O.; Data Curation, M.A.A.-O.; Writing-Original Draft Preparation, A.H.K.; Writing-Review & Editing, A.H.K. and A.E.-G.E.A.; Supervision, A.H.K. and A.E.-G.E.A.; Project Administration, M.A.A.-O.; Funding Acquisition, M.A.A.-O. and A.E.-G.E.A.

Funding

The authors are grateful to the Deanship of Scientific Research, King Saud University for funding this work through research group project “RGP-1435-047”.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Tyrala, E.E.; Brodsky, E.L.; Auerbach, V. Urinary copper losses in infants receiving free amino acid solutions‏. Am. J. Clin. Nutr. 1982, 35, 542–545. [Google Scholar] [CrossRef] [PubMed]
  2. Narli, I.; Kiralp, S.; Toppare, L. Preventing inhibition of tyrosinase with modified electrodes. Anal. Chim. Acta 2006, 572, 25–31. [Google Scholar] [CrossRef] [PubMed]
  3. Bull, P.C.; Cox, D.W. Wilson disease and Menkes disease: New handles on heavy-metal transport‏. Trends Genet. 1994, 10, 246–252. [Google Scholar] [CrossRef]
  4. Schaefer, M.; Gitlin, G.D. Wilson’s disease and Menkes disease. Am. J. Physiol. 1999, 276, 311–315. [Google Scholar] [CrossRef] [PubMed]
  5. Pinto, F.G.; Andrada, D.; Rey, U.V.; Ansaloni, L.M.S.; Borba da Silva, J.B. Employment of Ruthenium as Permanent Modifier for the Determination of Copper in Serum Samples by Electrothermal Atomic Absorption Spectrometry. Anal. Lett. 2006, 39, 2441–2451. [Google Scholar] [CrossRef]
  6. Cassella, R.J.; Magalhaes, O.I.B.; Couto, M.T.; Lima, E.L.S.; Neves, M.A.F.S.; Coutinho, F.M.B. Synthesis and application of a functionalized resin for flow injection/FAAS copper determination in waters. Talanta 2005, 67, 121–128. [Google Scholar] [CrossRef] [PubMed]
  7. Ferreira, S.L.C.; Queiroz, A.S.; Fernandes, M.S.; dos Santos, H.C. Application of factorial designs and Doehlert matrix in optimization of experimental variables associated with the preconcentration and determination of vanadium and copper in seawater by inductively coupled plasma optical emission spectrometry. Spectrochim. Acta Part B 2002, 57, 1939–1950. [Google Scholar] [CrossRef]
  8. Debrah, E.; Denoyer, E.R.; Tyson, J.F. Flow injection determination of mercury with preconcentration by amalgamation on a gold–platinum gauze by inductively coupled plasma mass spectrometry. J. Anal. At. Spectrom. 1996, 11, 127–132. [Google Scholar] [CrossRef] [Green Version]
  9. Mohadesi, A.; Taher, M.A. Voltammetric determination of Cu(II) in natural waters and human hair at a meso-2,3-dimercaptosuccinic acid self-assembled gold electrode. Talanta 2007, 72, 95–100. [Google Scholar] [CrossRef] [PubMed]
  10. Shams, E.; Torabi, R. Determination of nanomolar concentrations of cadmium by anodic-stripping voltammetry at a carbon paste electrode modified with zirconium phosphated amorphous silica. Sens. Actuat. B 2006, 117, 86–92. [Google Scholar] [CrossRef]
  11. Ali, A.; Shen, H.; Yin, X. Simultaneous determination of trace amounts of nickel, copper and mercury by liquid chromatography coupled with flow-injection on-line derivatization and preconcentration. Anal. Chim. Acta 1998, 369, 215–223. [Google Scholar] [CrossRef]
  12. Harvey, D. Modern Analytical Chemistry; Wiley: New York, NY, USA, 2000; p. 816. [Google Scholar]
  13. Ivaska, A.; Kubiak, W.W. Application of sequential injection analysis to anodic stripping voltammetry. Talanta 1997, 44, 713–723. [Google Scholar] [CrossRef]
  14. Barreto, S.R.G.; Nozaki, J. Spectrophotometric Determination of Copper in Metallic Alloy Using a Bidithiolene: A Comparative Study. Microchem. J. 1999, 62, 223–228. [Google Scholar] [CrossRef]
  15. Chimpalee, N.; Chimpalee, D.; Lohwithee, S.; Nakwatchara, L.; Burns, D.T. Spectrophotometric determination of copper after extraction of its chelate with bis(acetylacetone)ethylenediimine. Anal. Chim. Acta 1996, 329, 315–318. [Google Scholar] [CrossRef]
  16. Karabocek, S.; Nohut, S.; Dalman, O.; Guner, S. A new spectrophotometric reagent for copper: 3,3′-(1,3-propanediyldiimine) bis-[3-methyl-2-butanone]dioxime. Anal. Chim. Acta 2000, 408, 163–168. [Google Scholar] [CrossRef]
  17. Van Staden, J.F.; Botha, A. Spectrophotometric determination of Cu (II) with sequential injection analysis. Talanta 1999, 49, 1099–1108. [Google Scholar] [CrossRef]
  18. Neudachina, L.K.; Oshintseva, E.V.; Skorik, Y.A.; Vshivkova, A.A. N-Aryl-3-Aminopropionic acids as selective reagents for the determination of copper in metallurgical products. J. Anal. Chem. 2005, 60, 240–246. [Google Scholar] [CrossRef]
  19. Kamel, A.H.; Mahmoud, W.H.; Mostafa, M.S. Response Characteristics of Copper-Selective Polymer Membrane Electrodes Based on a Newly Synthesized Macrocyclic Calix[4]arene Derivative as a Neutral Carrier Ionophore. Electroanalysis 2010, 22, 2453–2459. [Google Scholar] [CrossRef]
  20. Kamel, A.H.; Kalifa, M.E.; Abd El-Maksoud, S.A.; Elgendy, F.A. Fabrication of novel sensors based on a synthesized acyclic pyridine derivative ionophore for potentiometric monitoring of copper. Anal. Methods 2014, 6, 7814–7822. [Google Scholar] [CrossRef]
  21. Hassan, S.S.M.; Elnemma, E.M.; Kamel, A.H. Novel potentiometric copper (II) selective membrane sensors based on cyclic tetrapeptide derivatives as neutral ionophores. Talanta 2015, 66, 1034–1041. [Google Scholar] [CrossRef] [PubMed]
  22. Kamel, A.H.; Galal, H.R.; Awwad, N.S. Cost-effective and handmade paper-based potentiometric sensing platform for piperidine determination. Anal. Methods 2018, 10, 5406–5415. [Google Scholar] [CrossRef]
  23. Crespo, G.A. Recent advances in ion-selective membrane electrodes for in situ environmental water analysis. Electrochim. Acta 2017, 245, 1023–1034. [Google Scholar] [CrossRef]
  24. Van de Velde, L.; Angremont, E.; Olthuis, W. Solid contact potassium selective electrodes for biomedical applications-a review. Talanta 2016, 160, 56–65. [Google Scholar] [CrossRef] [PubMed]
  25. Zuliani, C.; Diamond, D. Opportunities and challenges of using ion-selective electrodes in environmental monitoring and wearable sensors. Electrochim. Acta 2012, 84, 29–34. [Google Scholar] [CrossRef] [Green Version]
  26. Kamel, A.H.; Almedia, S.A.A.; Sales, M.G.F.; Moreira, F.T.C. Sulfadiazine-Potentiometric Sensors for Flow and Batch Determinations of Sulfadiazine in Drugs and Biological Fluids. Anal. Sci. 2009, 25, 365–371. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  27. Michalska, A. Optimizing the analytical performance and construction of ion-selective electrodes with conducting polymer-based ion-to-electron transducers. Anal. Bioanal. Chem. 2006, 384, 391–406. [Google Scholar] [CrossRef] [PubMed]
  28. Bobacka, J. Conducting polymer-based solid-state ion-selective electrodes. Electroanalysis 2010, 18, 7–18. [Google Scholar] [CrossRef]
  29. Hernández, R.; Riu, J.; Bobacka, J.; Vallés, C.; Jiménez, P.; Benito, A.M.; Maser, W.K.; Rius, F.X. Reduced graphene oxide films as solid transducers in potentiometric all solid-state ion-selective electrodes. J. Phys. Chem. C 2012, 116, 22570–22578. [Google Scholar] [CrossRef]
  30. Ye, J.; Li, F.; Gan, S.; Jiang, Y.; An, Q.; Zhang, Q.; Niu, L. Using sp2-C dominant porous carbon sub-micrometer spheres as solid transducers in ion-selective electrodes. Electrochem. Commun. 2015, 50, 60–63. [Google Scholar]
  31. Rius-Ruiz, F.X.; Crespo, G.A.; Bejarano-Nosas, D.; Blondeau, P.; Riu, J.; Rius, F.X. Potentiometric strip cell based on carbon nanotubes as transducer layer: Toward low-cost decentralized measurements. Anal. Chem. 2011, 83, 8810–8815. [Google Scholar] [CrossRef] [PubMed]
  32. Roy, S.; David-Pur, M.; Hanein, Y. Carbon nanotube-based ion selective sensors for wearable applications. ACS Appl. Mater. Interface 2017, 9, 35169–35177. [Google Scholar] [CrossRef] [PubMed]
  33. Wardak, C.; Lenik, J. Application of ionic liquid to the construction of Cu(II) ion-selective electrode with solid contact. Sens. Actuat. B 2013, 189, 52–59. [Google Scholar] [CrossRef]
  34. Fan, Y.; Xu, C.; Wang, R.; Hu, G.; Miaoc, J.; Haia, K.; Lin, C. Determination of copper(II) ion in food using an ionic liquids-carbon nanotubes-based ion-selective electrode. J. Food Comp. Anal. 2017, 62, 63–68. [Google Scholar] [CrossRef]
  35. Ganjali1, M.R.; Aghabalazadeh, S.; Khoobi, M.; Ramazani, A.; Foroumadi, A.; Shafiee, A.; Norouzi, P. Nanocomposite Based Carbon Paste Electrode for Selective Analysis of Copper. Int. J. Electrochem. Sci. 2011, 6, 52–62. [Google Scholar]
  36. Liang, R.; Yin, T.; Qin, W. A simple approach for fabricating solid-contact ion-selective electrodes using nanomaterials as transducers. Anal. Chim. Acta 2015, 853, 291–296. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  37. Pięk, M.; Fendrych, K.; Smajdor, J.; Piech, R.; Paczosa-Bator, B. High selective potentiometric sensor for determination of nanomolar concentration of Cu(II) using a polymeric electrode modified by a graphene/7,7,8,8 tetracyanoquinodimethane nanoparticles. Talanta 2017, 170, 41–48. [Google Scholar] [CrossRef] [PubMed]
  38. Mattinen, U.; Rabiej, S.; Lewenstam, A.; Bobacka, J. Impedance study of the ion-to-electron transduction process for carbon cloth as solid-contact material in potentiometric ion sensors. Electrochim. Acta 2011, 56, 10683–10687. [Google Scholar] [CrossRef]
  39. Bobacka, J. Potential Stability of All-Solid-State Ion-Selective Electrodes Using Conducting Polymers as Ion-to-Electron Transducers. Anal. Chem. 1999, 71, 4932–4937. [Google Scholar] [CrossRef] [PubMed]
  40. Bakker, E. Determination of improved selectivity coefficients of polymer membrane ion-selective electrodes by conditioning with a discriminated ion. J. Electrochem. Soc. 1996, 143, L83–L85. [Google Scholar] [CrossRef]
  41. Brinić, S.; Buzuk, M.; Bralić, M.; Generalić, E. Solid-contact Cu(II) ion-selective electrode based on 1,2-di-(o-salicylaldiminophenylthio) ethane. J. Solid State Electrochem. 2012, 16, 1333–1341. [Google Scholar] [CrossRef]
  42. Andac, M.; Coldur, F.; Bilir, S.; Birinci, A.; Demir, S.; Uzun, H. Solid-contact polyvinyl chloride membrane electrode based on the bis[(2(hydroxyethylimino) phenolato] copper(II) complex for trace level determination of copper ions in wastewater. Can. J. Chem. 2014, 92, 324–328. [Google Scholar] [CrossRef]
  43. Woznica, E.; Wojcik, M.M.; Mieczkowski, J.; Maksymiuk, K.; Michalska, A. Dithizone Modified Gold Nanoparticles Films as Solid Contact for Cu2+ Ion-Selective Electrodes. Electroanalysis 2013, 25, 141–146. [Google Scholar] [CrossRef]
  44. Birinci, A.; Eren, H.; Coldur, F.; Coskun, E.; Andac, M. Rapid determination of trace level copper in tea infusion samples by solid contact ion selective electrode. J. Food Drug Anal. 2016, 24, 485–492. [Google Scholar] [CrossRef] [PubMed] [Green Version]
  45. Amr, A.E.; Mohamed, A.M.; Ibrahim, A.A. Synthesis of some new chiral tricyclic and macrocyclic pyridine derivatives as antimicrobial agents‏. Z. Naturfosch. 2003, 58b, 861. [Google Scholar] [CrossRef]
Sample Availability: Not available.
Figure 1. Copper ionophore and electrode design.
Figure 1. Copper ionophore and electrode design.
Molecules 24 00920 g001
Figure 2. Chronopotentiometric results done for GC/Cu2+-ISEs (CWE), GC/PEDOT/PSS/Cu2+-ISEs and GC/SWCNTs/Cu2+-ISEs, applying anodic/cathodic current of 10 nA, in 0.01 M NaCl.
Figure 2. Chronopotentiometric results done for GC/Cu2+-ISEs (CWE), GC/PEDOT/PSS/Cu2+-ISEs and GC/SWCNTs/Cu2+-ISEs, applying anodic/cathodic current of 10 nA, in 0.01 M NaCl.
Molecules 24 00920 g002
Figure 3. Recorded potential time traces for the proposed Cu2+-ISEs. The inset shows the corresponding calibration curves.
Figure 3. Recorded potential time traces for the proposed Cu2+-ISEs. The inset shows the corresponding calibration curves.
Molecules 24 00920 g003
Figure 4. Water film tests of the solid-contact Cu2+-ISEs and of the CWE. At t = 1 h, the solution of the primary ion (10−5 M Cu2+) was exchanged to 10−1 M NaCl. At t = 2 h, the initial solution was inserted.
Figure 4. Water film tests of the solid-contact Cu2+-ISEs and of the CWE. At t = 1 h, the solution of the primary ion (10−5 M Cu2+) was exchanged to 10−1 M NaCl. At t = 2 h, the initial solution was inserted.
Molecules 24 00920 g004
Table 1. Response characteristics of solid contact-Cu2+-ISEs.
Table 1. Response characteristics of solid contact-Cu2+-ISEs.
ParameterGC/Cu2+-ISE (CWE)GC/SWCNTs/Cu2+-ISEGC/PEDOT/PSS/Cu2+-ISE
Slope (mV/decade)28.0 ± 0.427.8 ± 0.328.1 ± 0.4
Correlation coefficient (r2)0.99930.99970.9990
Detection limit (M)5.0 × 10−105.4 × 10−105.0 × 10−10
Linear range (M)1.0 × 10−9–1.0 × 10−22.0 × 10−9–1.0 × 10−21.0 × 10−9–1.0 × 10−2
Response time (s)<5<5<5
Working pH range (pH)3.0–6.53.0–6.53.0–6.5
Accuracy (mV%)99.699.398.8
Precision (mV%)1.11.21.7
Between-day variability (mV%)0.91.51.3
Table 2. Potentiometric selectivity coefficients (log KCu, J) ± SD obtained for the proposed sensors.
Table 2. Potentiometric selectivity coefficients (log KCu, J) ± SD obtained for the proposed sensors.
Interfering Ion, Jlog KCu, J ± SD
GC/Cu2+-ISEGC/SWCNTs-Cu2+-ISEGC/PEDOT/PSS/Cu2+-ISE
Na+−6.5 ± 0.3−6.6 ± 0.4−6.3 ± 0.3
Mg2+−8.4 ± 0.1−8.5 ± 0.3−8.4 ± 0.4
Ca2+−8.8 ± 0.2−8.7 ± 0.1−8.6 ± 0.3
K+−5.1 ± 0.7−5.0 ± 0.6−5.0 ± 0.5
Pb2+−4.5 ± 0.8−4.3 ± 0.4−4.4 ± 0.1
Cd2+−7.6 ± 0.2−7.6 ± 0.3−7.4 ± 0.4
Zn2+−7.2 ± 0.3−7.3 ± 0.1−7.4 ± 0.2
Ni2+−8.1 ± 0.7−8.2 ± 0.4−8.0 ± 0.3
Ag+−3.9 ± 0.4−3.7 ± 0.7−3.8 ± 0.4
Hg2+−4.1 ± 0.5−4.2 ± 0.3−4.1 ± 0.4
Table 3. Application of the proposed sensor to determination of Cu2+ ions in tap water samples.
Table 3. Application of the proposed sensor to determination of Cu2+ ions in tap water samples.
Sample(µg/mL) *Recovery (%)
Proposed SensorAASAddedFound
Sample 11.10 ± 0.21.05 ± 0.30.31.42 ± 0.1106.6
0.51.62 ± 0.2104.0
0.81.87 ± 0.396.2
Sample 20.80 ± 0.070.82 ± 0.040.31.08 ± 0.493.3
0.51.31 ± 0.2102.0
0.81.58 ± 0.197.5
* Average of 5 measurements.
Table 4. Copper assessments in tea samples using solid contact Cu2+-ISE.
Table 4. Copper assessments in tea samples using solid contact Cu2+-ISE.
Tea SamplesCopper Content ± SD (mg/Kg) at-Test b
PotentiometryAAS
Lipton (Black Sri Lankan Tea, Cairo, Egypt)8.3 ± 0.78.0 ± 0.32.37
Ahmed Tea (Black Tea, London, UK)12.3 ± 0.512.6 ± 0.42.61
Al-Arosa (Dust Black Kenyan tea, Cairo, Egypt)23.4 ± 0.822.8 ± 0.22.53
Al-Rabea (Black Tea, Riyadh, Saudi Arabia)21.3 ± 0.622.1 ± 0.32.67
Dilmah (Sri Lankan Tea, London, UK)17.3 ± 0.816.7 ± 0.12.43
a Average of three replicate measurements ± standard deviation. b The theoretical values of t at p = 0.05 is 2.78.
Table 5. Comparison of the potentiometric characteristic response of the presented ISEs and other previously reported solid contact Cu2+-ISEs.
Table 5. Comparison of the potentiometric characteristic response of the presented ISEs and other previously reported solid contact Cu2+-ISEs.
IonophoreSolid Contact MaterialSlope, mV/DecadeDetection Limit, MLinear Range, MPotential Drift, µV/sCapacitance, µFSelectivity Coefficients, log KCu2+, J, Method UsedRef.
o-Xylylene bis (N,N-diisobutyldithiocarbamateGraphite31.34.9 × 10−71.0 × 10−6–1.0 × 10−2NRNRCo2+ (−3.8), Na+ (−4.7), K+ (−2.4), Zn2+ (−5.2), Ba2+ (−4.5), NH4+ (−4.1), Ni2+ (−2.3), Cd2+ (−3.0), Ca2+ (−3.5), Pb2+ (−2.5). SSM[44]
N,N,N′,N′-Tetradodecyl-3,6-dioxaoctanedithioamideSWCNTs29.84.0 × 10−91.0 × 10−4–1.0 × 10−85.2 Na+ (−10.5), K+ (−8.6), Ca2+ (−11.9), Mg2+ (−13.3). SSM[36]
N,N,N′,N′-Tetracyclohexyl-2,2′-thiodiacetamide1-Ethyl-3-methyl imidazolium chloride.28.93.2 × 10−81.0 × 10−7–1.0 × 10−1NRNRCo2+ (−3.16), Na+ (−4.95), K+ (−5.21), Zn2+ (−3.39), Mg2+ (−6.22), Li+ (−5.11), Ni2+ (−3.02), Cd2+ (−3.84), Ca2+ (−4.93). SSM[33]
1-(2-Aminoethyl)-3-butyl imidazolium bis (trifluoromethane sulfonyl) imideCarboxylic multi-walled carbon nanotubes (MWCNTs-COOH)8.177.9 × 10−111.0 × 10-10–1.0 × 10−5NRNRCo2+ (−2.7), Na+ (−4.1), K+ (−3.9), Zn2+ (−2.5), Mg2+ (−3.4), NH4+ (−3.5), Ni2+ (−3.0), Mn2+ (−3.7), Ca2+ (−3.0), Pb2+ (−3.1), Cr3+ (−3.3), Fe3+ (−3.3). FIM[34]
(bis-[(2-(Hydroxyethylimino) phenolato]copper(II))NR28.38.3 × 10−71.0 × 10−6−1.0 × 10−1NRNRNa+ (−4.3), K+ (−4.3), Ca2+ (−4.4), Ba2+ (−4.5), Pb2+ (−3.8), Zn2+ (−3.0), Co2+ (−3.1), Ni2+ (−3.2), Cd2+ (−4.6), Cr3+ (−1.6). SSM[42]
3-(2-Methyl-2,3-dihydrobenzothiazol-2-yl)-2H-chromen-2-oneMWCNTs29.37.9 × 10−71.0 × 10−6−1.0 × 10−1NRNRHg2+ (−2.3), Lu3+ (−2.5), K+ (−3.1), Zn2+ (−3.9), Gd2+ (−3.8), Ag+ (−3.7), Ni2+ (−3.8), Mn2+ (−2.8), Cd2+ (−3.8), Ca2+ (−3.1), Pb2+ (−3.5), Cr3+ (−2.3), Fe3+ (−2.8), La3+ (−3.2). MPM[35]
7,7,8,8-TetracyanoquinodimethaneGraphen (GR)
Graphenoxide (GO)
30.5
30.6
1.0 × 10−9.2
1.0 × 10−7.5
1.0 × 10−9–1.0 × 10−2
1.0 × 10−7–1.0 × 10−2
20.2
54.5
495
183
K+ (−5.02), Na+ (−5.26), Ag+ (3.40), Mg2+ (−5.89), Ca2+ (−5.06), Zn2+ (−2.49), Pb2+ (−1.88), Ni2+ (−2.52). SSM
K+ (−5.52), Na+ (−6.27), Ag+ (3.42), Mg2+ (−6.84), Ca2+ (−5.76), Zn2+ (−2.94), Pb2+ (−2.76), Ni2+ (−2.97). SSM
[37]
DithizoneGold nanoparticle23.5
24.1
22.1
1.0 × 10−5.5
1.0 × 10−6
1.0 × 10−7.5
1.0 × 10−5–1.0 × 10−1
1.0 × 10−5–1.0 × 10−1
1.0 × 10−7–1.0 × 10−1
NR
NR
NR
11
14
13
K+ (−3.8), Na+ (−6.2), Mg2+ (−8.2), Ca2+ (−8.7), Zn2+ (−7.1), Pb2+ (−3.2), Ni2+ (−8.1), Cd2+ (−6.0). SSM
K+ (−3.0), Na+ (−5.2), Mg2+ (−7.3), Ca2+ (−7.8), Zn2+ (−6.3), Pb2+ (−3.1), Ni2+ (−7.2), Cd2+ (−5.4). SSM
K+ (−2.3), Na+ (−2.9), Mg2+ (−4.4), Ca2+ (−6.1), Zn2+ (−4.1), Pb2+ (−1.7), Ni2+ (−4.5), Cd2+ (−4.5). SSM
[43]
1,2-di-(o-Salicylaldimino -phenylthio) ethaneCarbon ink31.01.6 × 1063.2 × 106–2.8 × 102NRNRK+ (−7.0), Na+ (−7.0), Mn2+ (−2.6), Ca2+ (−7.0), Zn2+ (−2.3), Pb2+ (−2.0), Ni2+ (−7.0), Cd2+ (−4.1), Ag+ (−7.0), Co2+ (−5.0), Fe2+ (−5.0). MPM[41]
Macrocyclic calix[4]arene derivativeSWCNTs
PEDOT/PSS
27.8 ± 0.3
28.1 ± 0.4
5.4 × 10−10
5.0 × 10−10
1.0 × 10−3–2.0 × 10−9
1.0 × 10−3–1.0 × 10−9
30.1 ± 2.5
16.6 ± 1.2
33.3 ± 1.3
60.2 ± 0.2
Mg2+ (−8.5), Na+ (−6.6), K+ (−5.0), Zn2+ (−7.3), Hg2+ (−4.2), Ag+ (−3.7), Ni2+ (−8.2), Cd2+ (−7.6), Ca2+ (−8.7), Pb2+ (−4.3). SSM
Mg2+ (−8.4), Na+ (−6.3), K+ (−5.0), Zn2+ (−7.4), Hg2+ (−4.1), Ag+ (−3.8), Ni2+ (−8.0), Cd2+ (−7.4), Ca2+ (−8.6), Pb2+ (−4.4). SSM
This work
SSM: Separate solution method. MPM: Matched potential method. FIM: Fixed interference method. NR: Not reported.

Share and Cite

MDPI and ACS Style

E. Amr, A.E.-G.; Al-Omar, M.A.; H. Kamel, A.; A. Elsayed, E. Single-Piece Solid Contact Cu2+-Selective Electrodes Based on a Synthesized Macrocyclic Calix[4]arene Derivative as a Neutral Carrier Ionophore. Molecules 2019, 24, 920. https://doi.org/10.3390/molecules24050920

AMA Style

E. Amr AE-G, Al-Omar MA, H. Kamel A, A. Elsayed E. Single-Piece Solid Contact Cu2+-Selective Electrodes Based on a Synthesized Macrocyclic Calix[4]arene Derivative as a Neutral Carrier Ionophore. Molecules. 2019; 24(5):920. https://doi.org/10.3390/molecules24050920

Chicago/Turabian Style

E. Amr, Abd El-Galil, Mohamed A. Al-Omar, Ayman H. Kamel, and Elsayed A. Elsayed. 2019. "Single-Piece Solid Contact Cu2+-Selective Electrodes Based on a Synthesized Macrocyclic Calix[4]arene Derivative as a Neutral Carrier Ionophore" Molecules 24, no. 5: 920. https://doi.org/10.3390/molecules24050920

Article Metrics

Back to TopTop