Urban Rail System Modeling and Simulation Based on Dynamic Train Density

1
School of Electrical and Information Engineering, Hunan University of Technology, Zhuzhou 412007, China
2
School of Computer Science, University of Glasgow, Glasgow G12 8QQ, UK
*
Author to whom correspondence should be addressed.
Electronics 2024, 13(5), 853; https://doi.org/10.3390/electronics13050853
Submission received: 22 January 2024 / Revised: 14 February 2024 / Accepted: 16 February 2024 / Published: 23 February 2024
(This article belongs to the Topic Power System Modeling and Control, 2nd Volume)

Abstract

:
To further improve the simulation calculation ability of urban rail traction systems during the peak operation period and provide an accurate and reliable simulation tool for the subsequent train schedule and energy storage system design, a multi-train circuit model with a bilateral power supply was established in this paper, and a power calculation algorithm based on dynamic train density was designed. The circuit topology in the model can be dynamically adjusted according to the number of trains to improve the operation rate. Based on the spatial and electrical data of a real section of the subway, the urban rail circuit model was built on the MATLAB platform, and the actual operation data of the subway was imported for verification. The experimental results show that the multi-train model can accurately reflect the influence of voltage fluctuations on the traction system under different train running conditions, and the results fit the actual operation conditions. By comparing the influence of different train intervals on the RBE (regenerative braking energy) utilization, the results show that the optimal RBE utilization rate can be achieved by adjusting the train interval in the peak period.

1. Introduction

Urban rail transit is an efficient, safe, and environmentally friendly urban transportation mode, but it also faces problems such as high energy consumption, high operating costs, and large environmental impacts [1]. In order to improve the energy utilization efficiency and reduce the energy consumption of urban rail transit, the research on energy-saving technology of rail transit has become an important topic [2]. To reduce the comprehensive cost of design and verification of energy-saving technologies, such as timetable optimization [3] and energy storage system strategy [4], and to improve the efficiency and safety of the development process, it is necessary to establish an accurate urban rail equivalent simulation model. Regenerative braking technology [5] is the most basic energy-saving technology in urban rail systems. The way urban rail is currently modeled depends on how the regenerative braking energy is used. Chen and Hou et al. [6,7], based on the kinematic model of the train, used an evolutionary algorithm or a dynamic planning method to improve the acceleration and deceleration overlap time of the opposing train, so as to achieve the maximum utilization of RBE. The model can quickly complete the strategy verification under a long sampling step. However, the overlap time study ignores the coupling relationship between multiple trains and traction substations, so it is impossible to analyze the electrical quantities of each node of the traction system under this mutual influence. The train simulation model based on the MATLAB/Simulink motor module [8,9] can realize the comprehensive modeling of the motor, power electronics, and traction system on the basis of kinematics. However, a single-motor model cannot simulate realistic magnitude urban rail power [10], while increasing the number of motors increases the simulation time significantly. In order to improve the power simulation speed, current mainstream studies, such as the study by Saleh and Zhu et al. [11,12], usually equate the train as a current source with the traction system components to form an equivalent circuit model and use the current injection method to perform the current calculation in order to obtain the RBE and traction system power flow distribution. Compared with the literature [9], Khodaparastan et al. [13] used the equivalent circuit model to effectively improve the simulation speed and time span, which can realize the simulation analysis for 24 h. Zhu [14] investigated the problem of parameter tuning of the traction system and the energy storage system under different train operation scenarios. Sun [15] further combined the circuit model with the schedule optimization, equating the overlap time method to the overlap current method, and obtained a more accurate direct utilization of RBE through iterative current calculation, but the iterative calculation requires a lot of time. Chen et al. [16] proposed a method of calculating the current distribution without iteration in the system with fewer nodes and obtained the higher-order equations on the required train voltages by collating the node equations, and then input the circuit parameters to obtain the accurate train voltage, which further improved the simulation speed; however, during the peak period of operation, the interval time between trains decreased, resulting in an increase in the frequency of changes in the number of trains in the interval. In order to study the railway traffic quality under different train densities, Janusz Woch constructed the SOUT (System for Evaluation of Track Array) system [17]. In the research based on the SOUT system, Jeremi Rychlewski [18] analyzed the influence of train delay on traffic quality in the peak period, which further proves the importance of intelligent management. The delay of the train may lead to longer timetable confusion. For the urban rail traction system, the temporary change of the operation strategy during the operation of the train may bring an extremely unstable influence to the traction system.
In previous studies, the research on the urban rail model coupled with kinematics and electrics has basically been based on the fixed circuit topology. The purpose is to improve the utilization rate of RBE under a specific train condition, but this ignores the dynamic process of the train entering and leaving the interval during the peak period of operation, in this dynamic process; the power flow calculation based on the current injection method should also switch the circuit topology and the current injection position with the actual position of the train to avoid affecting the power flow calculation and RBE utilization analysis of the subsequent short-interval train entering the interval. The main contribution is to establish a fixed number of train models, and on this basis, an urban rail traction power calculation algorithm based on dynamic train density is designed. During the non-peak period, the algorithm can control the model to switch the circuit topology to a single train model. During the peak period of operation, the circuit topology is switched by calculating the number of trains in the interval in real time, and the current injection position is dynamically synchronized with the actual position of the train, which improves the dynamic characteristics of the power system and the accuracy of power flow calculation. The dynamic train density model is constructed on the MATLAB/Simulink platform, which proves the applicability of the model in full-time simulation. Under the same basic timetable, the simulation of different train interval time is set up. The results show that the control peak train interval time is 149 s and 179 s, which can achieve 25–32% RBE utilization.
The rest of the section is structured as follows: Section 2 presents the basic train model, traction substation, and contact network model. Section 3 describes the effect of dynamic train movements in the peak section on the model structure and the corresponding calculation method. Section 4 shows the model validation and simulation results. Section 5 summarizes the whole paper.

2. Urban Rail Traction System Model

2.1. Train Model

Subway vehicles consist of power cars and trailers, each of which is equipped with four traction motors. The electromagnetic torque generated by the traction motors is transmitted to the wheels through a gearbox to produce forward motion of the wheels, and the total traction force of the train is equal to the sum of the forces generated by all the traction motors. As shown in Figure 1, the train kinematic model is modeled in reverse [13], where the train number i and the corresponding displacement data xi are used to obtain the train velocity v and acceleration a through the derivation operation, and Newton’s second law (Equations (1) and (2)) is used to compute the traction force FT and braking force FB of the train.
v = d x d t
F T F B F W = m d v d t
where FW is the sum of the basic resistance per unit Fw0 and the additional resistance per unit Fwj, where the additional resistance consists of the ramp resistance and the curve resistance, which are calculated as Equations (3) and (4) [19], respectively.
F w 0 = 2.7551 + 0.014 v + 0.00075 v 2
F w j = g sin θ + g 700 R
In order to simplify the complexity of the train system, reduce the amount and time of calculation, and improve the operational efficiency and stability of the model, the traction power is calculated directly using Equation (5) to calculate the traction force, and the braking power is calculated by Equation (6), where ηm is the motor efficiency and ηi is the inverter efficiency.
P t = F T v η m η i
P b = F B v η m η i
In the current calculation, the train is modeled as a controlled current source, and its controlled signal is the current result of dividing the traction power calculated by the kinematic model with the train voltage. As shown in the parallel part of the controlled current source model in Figure 1, the on-board braking resistor is modeled as a series connection of a diode, an IGBT, and a braking resistor, and when the pantograph voltage VTrain exceeds the braking resistor activation threshold, the comparator generates a PWM control signal g to control the on-off of the IGBT to maintain the stability of the pantograph voltage.

2.2. Varying Catenary Resistance and Rail Resistance Models

As an example, if there are two trains in the section, according to the distance between the train and the traction substation, the variable catenary resistance can be expressed as Equations (7)–(9):
R u f = ( D t s 2 x t 1 ) Δ r
R u s = ( x t 1 x t 2 ) Δ r
R u t = ( x t 2 D t s 1 ) Δ r
If there is only one train in the section, the variable catenary resistance is expressed as Equations (10) and (11):
R u f = ( D t s 2 x t 1 ) Δ r
R u s = ( x t 1 D t s 1 ) Δ r
where Δr is the unit catenary resistance; Dts1 and Dts2 are the positions of the first and second traction stations; xt1 and xt2 are the real-time positions of train 1 and train 2, respectively; Ruf is the forward catenary resistance of the upline train; Rus is the catenary resistance between the upline double train or the backward catenary resistance of the upline train; Rut is the backward catenary resistance of the upline train that leans backward; and in the same way, Rdf, Rds, and Rdt correspond to the forward, middle and backward catenary resistance of the downline train. The rail resistance is replaced by the unit resistance Δrail. Taking Ruf, Rruf as an example, in order to intuitively reflect the real-time voltage fluctuation results of the catenary and rail, the catenary resistance and rail resistance are modeled as controlled voltage sources in Simulink, as shown in Figure 2; the control signal has a high degree of freedom, and the required algorithm can be designed on the basis of the basic control signal to expand the primary control function. Since the rail resistance is coupled with the trend of the catenary resistance, the two will be uniformly referred to as the catenary resistance in the subsequent discussion in order to better describe their change process.

2.3. Bilateral Power Supply Section Traction System Modeling

The bilateral power supply traction system consists of two traction substations and the contact network, as shown in Figure 3. The traction substations step down the 35 kV AC MV network through two 12-pulse transformers, each of which is Δ-connected on the network side, as well as Δ-connected and Y-connected on the valve side to reduce the harmonic component, and then rectify the full-wave rectifier to nominal 1500 V DC, which will be supplied to the contact network through the feeder circuit breakers. According to the number ratio of subway traction substation to passenger station in a city, the passenger station is set in the bilateral power supply system on average.
A section of the subway power supply in a certain city was selected as the research target. This section has three stations. The first and third stations are traction substations, which are set as Traction Substation 1 and Traction Substation 2, respectively. The second station is a step-down substation. Since it does not have energy interaction with the DC traction network under study, it will not be discussed in the model. Considering that the research is based on the peak period, to facilitate subsequent dynamic train density research, a circuit model topology with the highest train density was built, as shown in Figure 4. Due to the limitation of train safety distance and the ratio between the number of traction substations and passenger stations, the maximum number of trains in the same direction in the section is two; therefore, train 1 and train 2 were set up as double trains in the downline in the section, and train 3 and train 4 were set up as double trains in the upline in the section. Uts1, Uts2 and Its1, Its2 are, respectively, the output voltage and output current of the Traction Substation 1 and 2.

3. Circuit Topology Analysis and Dynamic Train Density Power Calculation Algorithm

3.1. Peak Period Traction System Circuit Topology Analysis

The specific change process of the number of trains in the peak area is shown in Figure 5. At t = t1, both train_j and train_j + 1 exist in area i, the catenary resistance is calculated by Equations (7)–(9), and P_Train_j and P_Train_j + 1 are injected into the corresponding trains into the controlled current source to carry out the calculation of the current. And when t = t2 moment, train_j leaves region i, and only train_j + 1 exists in the section; at this time, the peak state in the section changes to the low peak state in a shorter time range, and the catenary resistance should also be switched to the calculation of Equations (10) and (11). At the same time, the current injection of train_j + 1 should be switched to the position of P_Train_j at the moment of t1, which will provide the calculation of the subsequent import of train_j + 2 at the moment of t3 with a spare current source. According to the above analysis, if there is only one train on the one-way line, from the perspective of circuit calculation, the circuit topology can be constructed only by considering the resistance of the two lines before and after the train. However, in the circuit model, we need to think about how to deal with the third catenary resistance Rut in this case. There are two solutions: the first solution is to retain Rut and allocate the resistance of Rus to Rut equally; the second solution is to set the equivalent current source model of Rut and the second train to zero. The number of nodes on the line will be reduced and the circuit topology will be changed, and then the resistance of the line behind the train will be imported into Rus. In the circuit analysis at moments t1 and t2, as illustrated in Figure 5, it is evident that regardless of whether it is during the peak density of t1 or the lower density of t2, the value of Ruf is consistently determined by the position of the leading train within the interval. The value of Rus is influenced by both trains at t1 and is solely determined by the leading train at t2. On the other hand, Rut is consistently determined by the position of the trailing train within the interval. Therefore, considering the coupling relationship between different catenary resistances and each train, the second scheme was used to design the subsequent algorithm, which can avoid the non-synchronous condition that the number of trains changes; the number of catenary resistances in the circuit topology remained unchanged; and the motion phenomenon and circuit calculation of the train were further unified.
The number of trains and catenary resistance are summarized as shown in Table 1. Among them, S1 and S5 represent the state of only one train in the one-way interval, S2 and S6 represent the state of two trains, S3 and S7 represent the first train in the interval leaving the interval, S4 and S8 represent the state of no train in the interval, and RLi is the maximum resistance of the line in the interval. Taking the unidirectional urban rail system as a background example, when in the off-peak period, there is only one train coming in one direction, so only the S1 and S5 states may occur, the Rut and the rear train current source model is continuously set to zero, and Rus and Ruf are used for calculation. When the train leaves the zone in states S4 and S8, set Rus and all train current source models to zero, the value of Ruf is set to the maximum resistance of the line RLi, and off-peak period urban rail system modeling can be realized.
When in the peak period, the single-direction train state is in S3, S7 and S2, S6 cycle. At this time, the switching of the catenary resistance, as shown in the above analysis of Figure 5, is consistent with the number of trains and the number of states to give the Rus, and the corresponding train current source model of the zero signal to switch the topology of the circuit can be realized in the peak period of the urban rail system modeling.

3.2. Dynamic Train Density Power Calculation Algorithm

Considering the applicability of the model in the whole period, a power calculation algorithm of traction system based on train density in the interval is proposed on the circuit model of fixed topology. The algorithm consists of two modules: the upper train number control module and the lower power flow calculation module. The control flow is shown in Figure 6. The spatial and electrical data behavior is very important to the development of the algorithm. The relationship between the train position xtj and the selected substation position Dts_i determines whether the train can participate in the power calculation of the lower module. The upper module receives the train diagram data and counts by judging whether the train position is in the selected interval [Dts_i, Dts_i+2]. According to the number of trains, the judgment of the catenary resistance state in Table 1 is completed, and the zero signal and the resistance signal are generated and transmitted to the lower module. The lower layer module switches the circuit topology according to the zeroing signal. If the current is in the non-peak period (states S1, S5, S4, and S8), shown in Figure 6, the circuit topology is switched to the non-peak period topology. The power of the train is divided by the train voltage to obtain the basic signal of the train current source model, which is imported into the model for power calculation. If the current is the peak period (states S2 and S6), shown in Figure 6, the power of the train xtj and xtj+1 is processed as above, and the current source models before and after are imported, respectively, and the power calculation is carried out. After the power calculation of the current time step is completed, the program will return to the train number judgment step. If the number of trains is reduced during the peak period (states S3 and S7), the upper module can provide the circuit topology switching signal to the lower module in advance to ensure that the train power data can be imported into the correct train current source model, thus ensuring the accuracy of power calculation during non-peak and peak periods. After the circuit topology is switched, the power of the train xtj+1 is processed with the above and imported into the front current source for power calculation, which realizes the application of the model in the whole period. The main steps are as follows:
  • Import train diagram data, train parameters, and traction system parameters.
  • Judge whether the train distance xtj is in the selected interval [Dts_i, Dts_i+2] and count.
  • According to the total number of trains, and the resistance state of the line shown in Table 1, the zero-setting signal and impedance signal are generated.
  • If the state is S1, S5, S4, S8, the zero-signal switching circuit is used as a non-peak topology.
    • The basic signal of the train current source model is obtained by dividing the power of the train and the voltage of the train and import the model for power calculation.
    • After the calculation of the current time step is completed, return to step 2.
  • If the state is S2 and S6, the zero-signal switching circuit is used as the peak high-train-density topology.
    • After the power of the train xtj and xtj+1 is processed as above, the power calculation is carried out by introducing the current source model before and after.
    • If the states are S3 and S7, the zero-signal switching circuit is used as the peak low-train-density topology.
    • After the power of the train xtj+1 is processed as above, it is imported into the front current source for power calculation.
    • After the calculation of the current time step is completed, return to step 2.
  • Cycle from steps 2 to 5 until the end of the simulation.

4. Simulation Verification and Analysis

4.1. Dynamic Train Density-Based Traction System Model Verification

In order to verify the proposed dynamic train density metro rail circuit model in detail, the spatial location distribution of a power supply section in a metro line project was taken as the research object, and the train density traction system model was built in MATLAB/Simulink 2022b. The relevant parameters of the traction substation and the rectifier transformer parameters are shown in Table 2, and the basic data of the subway B-type car [20] are shown in Table 3. The line parameters of traction system are shown in Table 4.
To verify the accuracy of the model, actual measurements with 2000 samples per second were used as a benchmark for comparison. The items for comparison included the traction substation output voltage and train current. Part of the operating map data was imported into the train kinematics model, and the output voltage and train current obtained after model calculation are shown in Figure 7. During the periods of 8–22 s and 26–40 s, the demand current rose with the acceleration process of the train. During the period 22–26 s, the current dropped to a smaller value due to the reduced traction of the train. After 40 s, the train entered the braking phase, and the regenerative braking generated a large amount of current, resulting in a rapid increase in the output voltage of the traction substation in Figure 7c. At the same time, the braking resistor was activated and stabilized the voltage at its starting voltage threshold at 50 s. The simulation and experimental results show that the traction system-related data obtained from the simulation are very close to the actual current and voltage data. Figure 7d–f show the comparison between the simulation and actual situation of another section of the train running for a single time, and the simulation and actual operation knot further shows that the traction calculation model has a high degree of reduction.
The operating diagram data [20] for the time period from 17:15 to 17:22 was selected as shown in Figure 8a, and the time window was set to 400 s for dynamic train density model validation. Setting Figure 8b as the operating map curve under the synchronous condition of up and down trains was used to simulate the distribution of RBE utilization under the unoptimized operating map. Figure 8c is the operating diagram with the down train interval delayed by 30 s on the basis of the synchronized condition of the up and down trains to simulate the RBE utilization in the case that the trains cannot run exactly according to the schedule during the peak operation period.
According to the running diagram shown in Figure 8a, the dynamic train density model was verified. The change trend of the resistance of the upward catenary is shown in Figure 9a–c, and the change trend of the resistance of the downward catenary is shown in Figure 9d–f. Figure 9g–l represent the train entry signs in the upline and downline sections, respectively. From 0 to 180 s, the upline train in the interval was only one train, and the front- and rear- catenary resistance Ruf and Rus of the train can normally realize the change of train position. Between 180 and 190 s, the upline train 2 entered the interval, and the three catenary resistors were enabled at the same time. After 190 s, train 1 left the interval, while Ruf did not change to 0 but rose to 0.18 Ω, indicating that train 2 successfully realized position switching in circuit calculation. After train 2 left the interval in 340 s, train 3 repeated the calculation process of train 1. In summary, the proposed model effectively achieves the design goals of circuit topology changes and train cycle calculations during peak hours. The trend of the resistance of the downline was the same as that of the upline.
In the traction system current calculation based on the current injection method, the power of the train is usually injected and then divided by the real-time voltage values at the two ends of the controlled current sources as current injection. Figure 10a,b show the real-time injected power of the train current source in the down and uplines, respectively, and Figure 10c,d show the signs of the presence of the respective train numbers in the sections in the down and uplines, respectively. By comparing the train presence signs, it can be observed that in the upline, when train 1 was alone in the section (5–160 s), the system automatically allocated power to the first current source for current calculation. When train 2 was in the section (160–180 s), the traction power of train 2 was arranged to the second current source. When train 1 left the section at 190 s, the power injection of train 2 was automatically switched to the first current source; thus, the injected power of the second current source was abruptly reduced to 0, which provided a current injection location for train 3 to enter at the following 310 s. The above simulation cases show that the proposed dynamic train density model is able to accomplish the synchronization of the injected current position with the train kinematics in the case of short train time intervals.
The output voltage Uts and current Its of the traction substation comparing the dynamic train density model with the fixed topology model are shown in Figure 11. According to the train operation diagram shown in Figure 8a, it can be seen that in 0–40 s, the upline train 1 was close to UTs1 and started before the downline train 1, so the network voltage impact of UTs1 in Figure 11a was larger than that of UTs2 in Figure 11c. In 166–172 s, the dynamic train density model can simulate that the second train of the upline enters into the zone; the first train RBE was absorbed by the second train, which effectively suppressed the fluctuation of UTs1 and UTs2 in this period, while the fixed topology model was unable to simulate the traction system under the condition of changing number of trains in the peak period. After 250 s, as the number of trains in the interval changes frequently, the dynamic train density model can provide the traction system simulation results under complex train conditions. Figure 11b,d show the output currents of the traction substation under the dynamic train density model and fixed topology model models, respectively. The dynamic train density model can simulate the high load frequency of the traction substation in the case of frequent starting and stopping of trains during the peak period, and it demonstrates the feasibility of a good multi-train dynamic traction simulation.

4.2. Analysis of Operation Diagram and RBE Utilization Rate

In order to study the calculation effect of the proposed model on the RBE utilization rate at different intervals, multiple rounds of simulation were carried out based on the three operation diagrams shown in Figure 8. The RBE utilization rate is calculated by Equation (12):
η = j = 1 2 j _ s j _ e U d c _ j i d c _ j d t i = 1 4 t _ t s t _ t e P t d t + k = 1 6 t _ b s t _ b e i r e 2 Δ R L d t i = 1 4 t _ b s t _ b e P b d t
where the total RBE energy is calculated as the integral sum of all train braking powers Pb, the total catenary resistance loss is calculated as the sum of the losses of the six sections, and the direct utilization of RBE by the train reduces the total energy of the traction substation, so the RBE utilization rate η is calculated by the difference between the integral of the total train traction power Pt and the integral of the power of all the traction stations Pdc_j, divided by the total RBE energy.
Figure 12 shows the time-domain distribution of the influence of different train intervals on the utilization rate of RBE on the basis of the preset train diagram. With 159 s as the interval center term and 10 s as the tolerance, a total of eight different interval time differences were extended in two directions, thus forming nine train interval sequences. In Figure 12, the interval of 159 s is expressed as sequence 5, and the interval of 149 s and 179 s are expressed as sequence 4 and sequence 7. Case 1, case 2, and case 3 represent the RBE utilization distribution under the operation diagram shown in Figure 8a–c, respectively. By comparing case 2 and case 1, it can be found that under ideal conditions, the unified optimization of train diagram can effectively improve the overall RBE utilization rate by 10%. In the case of a fixed first train diagram, by modifying the interval time of subsequent trains to 139, 149, or 179 s, the braking and traction train conditions can be overlapped, as shown in the additional 149 and 179 s of the train diagram curve shown in Figure 8b, thereby continuing to increase the RBE utilization rate to a maximum of 32%.
Case 3 is the distribution of RBE utilization rate obtained by simulating the operation of train delays during the peak operation period. Compared with the ideal result of case 2, the interval time of the second train in the actual train diagram was increased to 210 s, resulting in the subsequent 300–400 s. The RBE utilization rate was less than that of case 2. In addition, at about 200 s, sequence 4 and sequence 7 represent the influence of overlapping conditions of multiple trains in the same direction and overlapping conditions of multiple trains in the opposite direction on the utilization rate of RBE, respectively. The same-direction utilization was affected by the change of resistance loss of catenary, and the RBE utilization rate was reduced by 5% compared with the opposite overlap condition. If the train interval is less than 149 s and more than 179 s, the overlapping conditions cannot be utilized, so the RBE utilization rate is greatly reduced. At this time, the energy storage system is required to indirectly utilize and realize the indirect utilization of RBE energy and maintain the stability of the traction network voltage.

5. Conclusions

Aiming at the problem of train density variation in urban rail rush hours, as the existing research does not analyze the dynamic circuit topology in detail, a multi-train system circuit model based on the dynamic train density calculation algorithm was proposed in this paper. Taking a certain subway project as the object, the time domain simulation of multi-train dynamic operation in a fixed area was carried out, and the time domain distribution of RBE utilization under different interval times was analyzed. The results show that the RBE utilization can be increased by up to 32% by optimizing the interval time of 149 s and 179 s in the ideal case of rush hours. By comparing the simulation results of the existing models with fixed number of trains in the whole period, the proposed dynamic train density model can expand the applicability of the existing model in the rush hours, and an effective simulation tool for the subsequent research on the combination of energy storage system strategy design and timetable optimization can be provided. However, the study focuses on realizing the dynamic train density function, and factors such as rail leakage current were not taken into account, so the calculation results have a slight error compared with the actual ones, and only the modeling in the bilateral power supply zones was considered. In the future, we will focus on improving the calculation accuracy of the model and expanding the model into a multi-zone simulation environment to better simulate the actual train operation. We will also conduct the study of cooperative voltage stabilization of multiple energy storage systems on the multi-zone model.

Author Contributions

X.W. provides the research direction and ideas and participates in the design and management of the whole system scheme; X.Y. participated in the software design and debugging and wrote the first draft; X.W. participated in writing, review, and editing; Y.Q. participated in verification, data processing, and writing, review, and editing. All authors have read and agreed to the published version of the manuscript.

Funding

Financial support was provided in part by the National Natural Science Foundation of China (grant numbers 62373142, 62033014, and 61903136) and the Natural Science Foundation of Hunan Province (grant numbers 2021JJ50006 and 2022JJ50074), Hunan Engineering Research Center of Electric Drive and Regenerative Energy Storage and Utilization.

Data Availability Statement

The simulation parameters of each module have been given in the paper, and the relevant data of train operation can be obtained by contacting the author by email.

Conflicts of Interest

The authors declare no conflicts of interest.

References

  1. Gao, Z.; Yang, L. Energy-saving operation approaches for urban rail transit systems. Front. Eng. Manag. 2019, 6, 139–151. [Google Scholar] [CrossRef]
  2. Bazdar, E.; Sameti, M.; Nasiri, F.; Haghighat, F. Compressed air energy storage in integrated energy systems: A review. Renew. Sustain. Energy Rev. 2022, 167, 112701. [Google Scholar] [CrossRef]
  3. Sasithong, P.; Parnianifard, A.; Sinpan, N.; Poomrittigul, S.; Saadi, M.; Wuttisittikulkij, L. Simulation-Based Headway Optimization for the Bangkok Airport Railway System under Uncertainty. Electronics 2023, 12, 3493. [Google Scholar] [CrossRef]
  4. Blanch-Fortuna, A.; Zambrano-Prada, D.; Gállego-Casals, M.; Martinez-Salamero, L. Simulation of an Ultrafast Charging Station Operating in Steady State. Electronics 2023, 12, 4811. [Google Scholar] [CrossRef]
  5. Zhang, L.; He, D.; He, Y.; Liu, B.; Chen, Y.; Shan, S. Real-time energy saving optimization method for urban rail transit train timetable under delay condition. Energy 2022, 258, 124853. [Google Scholar] [CrossRef]
  6. Hou, Z.; Dong, H.; Gao, S.; Nicholson, G.; Chen, L.; Roberts, C. Energy-saving metro train timetable rescheduling model considering ATO profiles and dynamic passenger flow. IEEE Trans. Intell. Transp. Syst. 2019, 20, 2774–2785. [Google Scholar] [CrossRef]
  7. Chen, X.; Guo, X.; Meng, J.; Xu, R.; Li, S.; Li, D. Research on ATO Control Method for Urban Rail Based on Deep Reinforcement Learning. IEEE Access 2023, 11, 5919–5928. [Google Scholar] [CrossRef]
  8. Wang, X.; Luo, Y.; Zhou, Y.; Qin, Y.; Qin, B. Hybrid energy management strategy based on dynamic setting and coordinated control for urban rail train with PMSM. IET Renew. Power Gener. 2021, 15, 2740–2752. [Google Scholar] [CrossRef]
  9. Wang, X.; Luo, Y.; Qin, B.; Guo, L. Power allocation strategy for urban rail HESS based on deep reinforcement learning sequential decision optimization. IEEE Trans. Transp. Electrif. 2023, 9, 2693–2710. [Google Scholar] [CrossRef]
  10. Zhong, Z.; Yang, Z.; Fang, X.; Lin, F.; Tian, Z. Hierarchical optimization of an on-board supercapacitor energy storage system considering train electric braking characteristics and system loss. IEEE Trans. Veh. Technol. 2020, 69, 2576–2587. [Google Scholar] [CrossRef]
  11. Zhu, F.; Yang, Z.; Lin, F.; Xin, Y. Decentralized cooperative control of multiple energy storage systems in urban railway based on multiagent deep reinforcement learning. IEEE Trans. Power Electron. 2020, 35, 9368–9379. [Google Scholar] [CrossRef]
  12. Saleh, M.; Dutta, O.; Esa, Y.; Mohamed, A. Quantitative analysis of regenerative energy in electric rail traction systems. In Proceedings of the 2017 IEEE Industry Applications Society Annual Meeting, Cincinnati, OH, USA, 1–5 October 2017; pp. 1–7. [Google Scholar]
  13. Khodaparastan, M.; Dutta, O.; Saleh, M.; Mohamed, A.A. Modeling and simulation of dc electric rail transit systems with wayside energy storage. IEEE Trans. Veh. Technol. 2019, 68, 2218–2228. [Google Scholar] [CrossRef]
  14. Zhu, F.; Yang, Z.; Lin, F.; Xin, Y. Synthetic optimization of traction power parameters and energy storage systems in urban rail transit. Trans. China Electrotech. Soc. 2019, 32, 16–23. [Google Scholar]
  15. Sun, P.; Zhang, C.; Jin, B.; Wang, Q.; Geng, H. Timetable optimization for maximization of regenerative braking energy utilization in traction network of urban rail transit. Comput. Ind. Eng. 2023, 183, 109448. [Google Scholar] [CrossRef]
  16. Chen, M.; Feng, X.; Wang, Q.; Sun, P. Cooperative eco-driving of multi-train under dc traction network. IEEE Trans. Transp. Electrif. 2021, 7, 1805–1821. [Google Scholar] [CrossRef]
  17. Woch, J. Narzędzia Analizy Efektywności i Optymalizacji Sieci Kolejowej:(System Oceny Układów Torowych-SOUT-Opis Podstawowego Oprogramowania); Wydawnictwo Politechniki Śląskiej: Gliwice, Poland, 2001. [Google Scholar]
  18. Jeremi, R. Evaluation of rail traffic quality in Poznań by computer simulation. CMST 2003, 9, 113–126. [Google Scholar]
  19. Zhao, N.; Tian, Z.; Chen, L.; Roberts, C.; Hillmansen, S. Driving strategy optimization and field test on an urban rail transit system. IEEE Intell. Transp. Syst. Mag. 2020, 13, 34–44. [Google Scholar] [CrossRef]
  20. Liu, Y.; Yang, B.; Xiao, S.; Zhu, T.; Yang, G.; Xiu, R. Research on the Influence of Multiple Parameters on the Responses of a B-type Subway Train. Chin. J. Mech. Eng. 2022, 35, 85. [Google Scholar] [CrossRef]
Figure 1. Train model.
Figure 1. Train model.
Electronics 13 00853 g001
Figure 2. Catenary resistance model.
Figure 2. Catenary resistance model.
Electronics 13 00853 g002
Figure 3. Bilateral power supply system model. The Δ on the top of the transformer indicates that the network side of the transformer is connected in a delta configuration, and the Y and Δ on the bottom of the transformer indicate that the valve side of the transformer is connected in a Y-type and delta configuration.
Figure 3. Bilateral power supply system model. The Δ on the top of the transformer indicates that the network side of the transformer is connected in a delta configuration, and the Y and Δ on the bottom of the transformer indicate that the valve side of the transformer is connected in a Y-type and delta configuration.
Electronics 13 00853 g003
Figure 4. Highest train density circuit model topology.
Figure 4. Highest train density circuit model topology.
Electronics 13 00853 g004
Figure 5. Peak period train status analysis.
Figure 5. Peak period train status analysis.
Electronics 13 00853 g005
Figure 6. Dynamic train density calculation algorithm flow.
Figure 6. Dynamic train density calculation algorithm flow.
Electronics 13 00853 g006
Figure 7. Simulation and actual data comparison: (a) Train Speed Curve 1; (b) Train Current Simulation and Actual Comparison under Speed Curve 1; (c) Train Pantograph Voltage Simulation and Actual Comparison under Speed Curve 1; (d) Train Speed Curve 2; (e) Train Current Simulation and Actual Comparison under Speed Curve 2; (f) Train Pantograph Voltage Simulation and Actual Comparison under Speed Curve 2.
Figure 7. Simulation and actual data comparison: (a) Train Speed Curve 1; (b) Train Current Simulation and Actual Comparison under Speed Curve 1; (c) Train Pantograph Voltage Simulation and Actual Comparison under Speed Curve 1; (d) Train Speed Curve 2; (e) Train Current Simulation and Actual Comparison under Speed Curve 2; (f) Train Pantograph Voltage Simulation and Actual Comparison under Speed Curve 2.
Electronics 13 00853 g007
Figure 8. Comparison of different operating charts, The blue line represents the position of the down train, while the orange line represents the position of the up train. (a) displays the urban rail train operating for the time period from 17:15 to 17:22; (b) displays the operational curve under the synchronous conditions of both up and down trains; (c) presents the operational curve, building upon (b), showcasing a 30-s delay between down trains to simulate delays during peak hours.
Figure 8. Comparison of different operating charts, The blue line represents the position of the down train, while the orange line represents the position of the up train. (a) displays the urban rail train operating for the time period from 17:15 to 17:22; (b) displays the operational curve under the synchronous conditions of both up and down trains; (c) presents the operational curve, building upon (b), showcasing a 30-s delay between down trains to simulate delays during peak hours.
Electronics 13 00853 g008
Figure 9. Dynamic catenary resistance and matrix transformation trigger signal verification. The curve of the Ruf values is shown in (a), while Rus is shown in (b) and Rut is shown in (c). (d) shows the change curve of Rdf, (e) shows the change curve of Rdt, (f) shows the change curve of Rdt, In (g,h), the signal set 1 represents the sign of the up train entering the interval, and set 0 is the train leaving the interval. The blue line twice set 1 represents the train_j and the train_j+2 entering the interval, and the orange line represents the train_j+1 entering the interval. The signal set 1 in (j,k) represents the sign of the down line train entering the interval, as described in (g,h). (i,l) The blue line signifies the signal indicating that both trains are in the interval.
Figure 9. Dynamic catenary resistance and matrix transformation trigger signal verification. The curve of the Ruf values is shown in (a), while Rus is shown in (b) and Rut is shown in (c). (d) shows the change curve of Rdf, (e) shows the change curve of Rdt, (f) shows the change curve of Rdt, In (g,h), the signal set 1 represents the sign of the up train entering the interval, and set 0 is the train leaving the interval. The blue line twice set 1 represents the train_j and the train_j+2 entering the interval, and the orange line represents the train_j+1 entering the interval. The signal set 1 in (j,k) represents the sign of the down line train entering the interval, as described in (g,h). (i,l) The blue line signifies the signal indicating that both trains are in the interval.
Electronics 13 00853 g009
Figure 10. Current injection position switching verification. (a) shows the real-time injected power curve of the current sources for down trains 1 and 2 in the section; (b) shows the injected power curve of the current source for up trains; (c) shows the signals indicating the entry of down trains into the section; (d) shows the signals indicating the entry of up trains into the section.
Figure 10. Current injection position switching verification. (a) shows the real-time injected power curve of the current sources for down trains 1 and 2 in the section; (b) shows the injected power curve of the current source for up trains; (c) shows the signals indicating the entry of down trains into the section; (d) shows the signals indicating the entry of up trains into the section.
Electronics 13 00853 g010
Figure 11. Voltage time domain variations between the bilateral power supply interval. (a) shows the voltage curve comparison of Uts1 under the dynamic train density model and the fixed topology model. (b) shows the comparative curve of Its1 under these two models; (c) shows the comparative curve of Uts2; (d) shows the comparative curve of Its2.
Figure 11. Voltage time domain variations between the bilateral power supply interval. (a) shows the voltage curve comparison of Uts1 under the dynamic train density model and the fixed topology model. (b) shows the comparative curve of Its1 under these two models; (c) shows the comparative curve of Uts2; (d) shows the comparative curve of Its2.
Electronics 13 00853 g011
Figure 12. Time domain distribution of RBE utilization at different intervals during the peak period. (a) shows the distribution of regenerative braking energy utilization rate under case 1, corresponding to the train operation curve in Figure 8b; (b) shows the distribution of regenerative braking energy utilization rate under case 2, corresponding to the train operation curve in Figure 8a; (c) shows the distribution of regenerative braking energy utilization rate under case 3, corresponding to the train operation curve in Figure 8c.
Figure 12. Time domain distribution of RBE utilization at different intervals during the peak period. (a) shows the distribution of regenerative braking energy utilization rate under case 1, corresponding to the train operation curve in Figure 8b; (b) shows the distribution of regenerative braking energy utilization rate under case 2, corresponding to the train operation curve in Figure 8a; (c) shows the distribution of regenerative braking energy utilization rate under case 3, corresponding to the train operation curve in Figure 8c.
Electronics 13 00853 g012
Table 1. Catenary resistance variations.
Table 1. Catenary resistance variations.
DirectionVariable Catenary ResistanceState
upline R u t + R u s = R u s , R u f S1
R u t , R u s , R u f S2
R u t + R u s = R u s , R u f S3
R L i S4
downline R d t + R d s = R d s , R d f S5
R d t , R d s , R d f S6
R d t + R d s = R d s , R d f S7
R L i S8
Table 2. Basic parameters of the traction substation.
Table 2. Basic parameters of the traction substation.
ParameterValue
Rated capacity of net side2 × 25 MVA
Rated capacity of value side2 × 3000 kVA
Net-side rated voltage35 kV
Value side rated voltage1210 V
No-load output voltage1680 V
Equivalent internal resistance0.03 Ω/km
Equivalent inductance0.0025 F
Table 3. Basic data of subway B-type vehicles.
Table 3. Basic data of subway B-type vehicles.
ParameterValue
Train formation4M2T
Average load52.4 t
Average passenger870
Total train weight241.4 t
Max acceleration1.0 m·s−2
Unit resistance2.7551 + 0.014v + 0.00075 v2
Braking resistor limiting voltage1800 V
Braking resistor starting voltage1730 V
Table 4. Catenary and rail parameters.
Table 4. Catenary and rail parameters.
ParameterValue
Distance between FDG and WJS730 m
Distance between WJS and MWD760 m
Catenary unit resistance0.013 Ω/km
Rail line unit resistance0.019 Ω/km
Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Share and Cite

MDPI and ACS Style

Yu, X.; Wang, X.; Qin, Y. Urban Rail System Modeling and Simulation Based on Dynamic Train Density. Electronics 2024, 13, 853. https://doi.org/10.3390/electronics13050853

AMA Style

Yu X, Wang X, Qin Y. Urban Rail System Modeling and Simulation Based on Dynamic Train Density. Electronics. 2024; 13(5):853. https://doi.org/10.3390/electronics13050853

Chicago/Turabian Style

Yu, Xinyang, Xin Wang, and Yuxin Qin. 2024. "Urban Rail System Modeling and Simulation Based on Dynamic Train Density" Electronics 13, no. 5: 853. https://doi.org/10.3390/electronics13050853