Comprehensive Survey on Improved Focality and Penetration Depth of Transcranial Magnetic Stimulation Employing Multi-Coil Arrays
Abstract
:1. Introduction
2. Materials and Methods
2.1. Computational Models
2.2. Coil Combinations of Diverse Energizing Strategies
2.3. Numerical Simulations
3. Results
3.1. Electric Field Attenuation Rate
3.2. Focality of Coil Combinations
3.3. Attenuation-Focality Tradeoff
3.4. Target Location by Multi-Coil Arrays
3.5. Comparison of Different Coils
4. Conclusions
Acknowledgments
Author Contributions
Conflicts of Interest
References
- Roth, Y.; Padberg, F.; Zangen, A. Transcranial magnetic stimulation of deep brain regions: Principles and methods. Adv. Biol. Psychiatry 2007, 23, 204–225. [Google Scholar]
- George, M.S.; Aston-Jones, G. Noninvasive techniques for probing neurocircuitry and treating illness: Vagus nerve stimulation (VNS), transcranial magnetic stimulation (TMS) and transcranial direct current stimulation (tDCS). Neuropsychopharmacology 2010, 35, 301–316. [Google Scholar] [CrossRef] [PubMed]
- Pascual-Leone, A.; Walsh, V.; Rothwell, J. Transcranial magnetic stimulation in cognitive neuroscience—Virtual lesion, chronometry, and functional connectivity. Curr. Opin. Neurobiol. 2000, 10, 232–237. [Google Scholar] [CrossRef]
- Rastogi, P.; Lee, E.G.; Hadimani, R.L.; Jiles, D.C. Transcranial Magnetic Stimulation-coil design with improved focality. AIP Adv. 2016, 7, 56701–56705. [Google Scholar] [CrossRef]
- Im, C.H.; Lee, C. Precise Estimation of Brain Electrical Sources Using Anatomically Constrained Area Source (ACAS) Localization. IEEE. Trans. Magn. 2007, 42, 1713–1716. [Google Scholar] [CrossRef]
- Ruohonen, J.; Ollikainen, M.; Nikouline, V.; Virtanen, J.; Ilmoniemi, R.J. Coil design for real and sham transcranial magnetic stimulation. IEEE Trans. Biomed. Eng. 2000, 47, 145–148. [Google Scholar] [CrossRef] [PubMed]
- Starzyn’ski, J.; Sawicki, B.; Wincenciak, S.; Krawczyk, A.; Zyss, T. Simulation of magnetic stimulation of the brain. IEEE Trans. Magn. 2002, 38, 1237–1240. [Google Scholar] [CrossRef]
- Roth, B.J.; Cohen, L.G.; Hallett, M.D.M.; Friauf, M.W.; Basser, P.J. Latency of motor evoked potentials to focal transcranial stimulation varies as a function of scalp positions stimulated. Electroencephalogr. Clin. Neurophysiol. 1991, 81, 81–89. [Google Scholar]
- Vahe, E.A.; Paul, J.M.; Roger, Q.C. Focal stimulation of human cortex with the magnetic coil: A comparison with electrical stimulation. Exp. Neurol. 1989, 74, 401–416. [Google Scholar]
- Gomez, L.; Cajko, F.; Hernandezgarcia, L.; Grbic, A.; Michielssen, E. Numerical analysis and design of single-source multicoil TMS for deep and focused brain stimulation. IEEE Trans. Biomed. Eng. 2013, 60, 2771–2782. [Google Scholar] [CrossRef] [PubMed]
- Ueno, S.; Tashiro, T.; Harada, K. Localized stimulation of neural tissues in the brain by means of a paired configuration of time-varying magnetic fields. J. Appl. Phys. 1988, 64, 5862–5864. [Google Scholar] [CrossRef]
- Cohen, L.G.; Roth, B.J.; Nilsson, J.; Dang, N.; Panizza, M.; Bandinelli, S.; Friauf, W.; Hallett, M. Effects of coil design on delivery of focal magnetic stimulation. Tech. Consid. Electroencephalogr. Clin. Neurophysiol. 1990, 75, 350–357. [Google Scholar] [CrossRef]
- Nyenhuis, J.A.; Mouchawar, G.A.; Bourland, J.D.; Geddes, L.A. Mouchawar, Influence of coil geometry on localization of the induced electric field in magnetic (eddy-current) stimulation of excitable tissue. IEEE Trans. Magn. 1990, 26, 1545–1547. [Google Scholar]
- Roth, B.J.; Saypol, J.M.; Hallett, M.; Cohen, L.G. A theoretical calculation of the electric field induced in the cortex during magnetic stimulation. Electroencephalogr. Clin. Neurophysiol. 1991, 81, 47–56. [Google Scholar] [CrossRef]
- Rossi, S.; Hallett, M.; Rossini, P.M.; Pascual-Leone, A. Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research. Clin. Neurophysiol. 2009, 120, 2008. [Google Scholar] [CrossRef] [PubMed]
- Crowther, L.J.; Marketos, P.; Williams, P.I.; Melikhov, Y.; Jiles, D.C.; Starzewski, J.H. Transcranial magnetic stimulation: Improved coil design for deep brain investigation. J. Appl. Phys. 2011, 109, 1357–1367. [Google Scholar] [CrossRef]
- Meng, Y.; Hadimani, R.L.; Crowther, L.J.; Xu, Z.; Qu, J.; Jiles, D.C. Deep brain transcranial magnetic stimulation using variable ‘Halo coil’ system. J. Appl. Phys. 2015, 117, 1106–1128. [Google Scholar] [CrossRef]
- Roth, Y.; Zangen, A.; Hallett, M. A coil design for transcranial magnetic stimulation of deep brain regions. J. Clin. Neurophysiol. 2002, 19, 361. [Google Scholar] [CrossRef] [PubMed]
- Deng, Z.D.; Lisanby, S.H.; Peterchev, A.V. Electric field depth–focality tradeoff in transcranial magnetic stimulation: Simulation comparison of 50 coil designs. Brain Stimul. 2013, 6, 1–13. [Google Scholar] [CrossRef] [PubMed]
- Deng, Z.D.; Lisanby, S.H.; Peterchev, A.V. Coil design considerations for deep transcranial magnetic stimulation. Clin. Neurophysiol. 2014, 125, 1202–1212. [Google Scholar] [CrossRef] [PubMed]
- Ruohonen, J.; Ravazzani, P.; Grandori, F.; Ilmoniemi, R.J. Theory of multichannel magnetic stimulation: Toward functional neuromuscular rehabilitation. IEEE Trans. Biomed. Eng. 1999, 46, 646. [Google Scholar] [CrossRef] [PubMed]
- Im, C.H.; Lee, C. Computer-Aided Performance evaluation of a multichannel transcranial magnetic stimulation system. IEEE Trans. Magn. 2006, 42, 3803–3808. [Google Scholar] [CrossRef]
- Cline, C.C.; Johnson, N.N.; He, B. Subject-specific optimization of channel currents for multichannel transcranial magnetic stimulation. In Proceedings of the 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Milan, Italy, 25–29 August 2015; pp. 2083–2086. [Google Scholar]
- Laakso, I.; Hirata, A.; Ugawa, Y. Effects of coil orientation on the electric field induced by TMS over the hand motor area. Phys. Med. Biol. 2014, 59, 203–218. [Google Scholar] [CrossRef] [PubMed]
- Thielscher, A.; Kammer, T. Electric field properties of two commercial figure-8 coils in TMS: Calculation of focality and efficiency. Clin. Neurophysiol. 2004, 115, 708–1697. [Google Scholar] [CrossRef] [PubMed]
- Janssen, M.; Oostendorp, T.F.; Stegeman, D.F. The coil orientation dependency of the electric field induced by TMS for M1 and other brain areas. J. Neuroeng. Rehabil. 2015, 12, 1–13. [Google Scholar] [CrossRef] [PubMed] [Green Version]
- Deng, Z.D. Electromagnetic Field Modeling of Transcranial Electric and Magnetic Stimulation: Targeting, Individualization, and Safety of Convulsive and Subconvulsive Applications; Columbia University: New York, NY, USA, 2013. [Google Scholar]
- Bersani, F.S.; Minichino, A.; Enticott, P.G.; Mazzarini, L.; Khan, N.; Antonacci, G. Deep transcranial magnetic stimulation as a treatment for psychiatric disorders: A comprehensive review. Eur. Psychiatry 2013, 28, 30–39. [Google Scholar] [CrossRef] [PubMed]
- Lee, W.H.; Lisanby, S.H.; Laine, A.F.; Peterchev, A.V. Comparison of electric field strength and spatial distribution of electroconvulsive therapy and magnetic seizure therapy in a realistic human head model. Eur. Psychiatry 2016, 36, 36–55. [Google Scholar] [CrossRef] [PubMed]
- Rochelabarbe, N.; Aarabi, A.; Kongolo, G.; Gondryjouet, C.; Dümpelmann, M.; Grebe, R.; Wallois, F. High-resolution electroencephalography and source localization in neonates. Hum. Brain Mapp. 2008, 29, 167–176. [Google Scholar] [CrossRef] [PubMed]
- Roth, Y.G.; Pell, S.; Zangen, A. Realistic shape head model and spherical model as methods for TMS coil characterization. Clin. Neurophysiol. 2014, 126, 1455–1456. [Google Scholar] [CrossRef] [PubMed]
- Guadagnin, V.; Parazzini, M.; Fiocchi, S. Deep transcranial magnetic stimulation: modeling of different coil configurations. IEEE Trans. Biomed. Eng. 2015, 63, 1543–1550. [Google Scholar] [CrossRef] [PubMed]
- Gao, F.; Zhang, F.S.; Wakatsuchi, H.; Sievenpiper, D.F. Synthesis and design of programmable subwavelength coil array for near-field manipulation. IEEE Trans. Microw. Theory Tech. 2015, 63, 2971–2982. [Google Scholar] [CrossRef]
- Windhoff, M.; Opitz, A.; Thielscher, A. Electric field calculations in brain stimulation based on finite elements: An optimized processing pipeline for the generation and usage of accurate individual head models. Hum. Brain Mapp. 2011, 34, 923–935. [Google Scholar] [CrossRef] [PubMed]
- Mcgirr, A.; Eynde, F.V.D.; Chachamovich, E.; Fleck, M.P.A.; Berlim, M.T. Personality dimensions and deep repetitive transcranial magnetic stimulation (dtms) for treatment-resistant depression: A pilot trial on five-factor prediction of antidepressant response. Neurosci. Lett. 2014, 563, 144–148. [Google Scholar] [PubMed]
- Lin, V.W.; Hsiao, I.N.; Dhaka, V. Magnetic coil design considerations for functional magnetic stimulation. IEEE Trans. Biomed. Eng. 2000, 47, 600–610. [Google Scholar] [CrossRef] [PubMed]
- Iwahashi, M.; Gomeztames, J.; Laakso, I.; Hirata, A. Evaluation method for in situ electric field in standardized human brain for different transcranial magnetic stimulation coils. Phys. Med. Biol. 2017, 62, 2224. [Google Scholar] [CrossRef] [PubMed]
Coil Combinations | Anticlockwise Current | Clockwise Current | CD |
---|---|---|---|
4-coil 01 | (1) (13) | (4) (16) | |
4-coil 02 | (6) (10) | (7) (11) | |
4-coil 03 | (1) (2) | (3) (4) | |
8-coil 01 | (1) (2) (3) (4) | (13) (14) (15) (16) | |
8-coil 02 | (1) (2) (9) (13) | (4) (8) (15) (16) | |
8-coil 03 | (2) (5) (9) (14) | (3) (8) (12) (15) | |
8-coil 04 | (1) (2) (5) (6) | (11) (12) (15) (16) | |
16-coil | (1)–(16) | - |
© 2017 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Share and Cite
Wei, X.; Li, Y.; Lu, M.; Wang, J.; Yi, G. Comprehensive Survey on Improved Focality and Penetration Depth of Transcranial Magnetic Stimulation Employing Multi-Coil Arrays. Int. J. Environ. Res. Public Health 2017, 14, 1388. https://doi.org/10.3390/ijerph14111388
Wei X, Li Y, Lu M, Wang J, Yi G. Comprehensive Survey on Improved Focality and Penetration Depth of Transcranial Magnetic Stimulation Employing Multi-Coil Arrays. International Journal of Environmental Research and Public Health. 2017; 14(11):1388. https://doi.org/10.3390/ijerph14111388
Chicago/Turabian StyleWei, Xile, Yao Li, Meili Lu, Jiang Wang, and Guosheng Yi. 2017. "Comprehensive Survey on Improved Focality and Penetration Depth of Transcranial Magnetic Stimulation Employing Multi-Coil Arrays" International Journal of Environmental Research and Public Health 14, no. 11: 1388. https://doi.org/10.3390/ijerph14111388