Abstract: Purpose: The purpose of this study was to investigate the face validity of the self-reported single item work ability with objectively measured heart rate reserve (%HRR) among blue-collar workers. Methods: We utilized data from 127 blue-collar workers (Female = 53; Male = 74) aged 18–65 years from the cross-sectional “New method for Objective Measurements of physical Activity in Daily living (NOMAD)” study. The workers reported their single item work ability and completed an aerobic capacity cycling test and objective measurements of heart rate reserve monitored with Actiheart for 3–4 days with a total of 5,810 h, including 2,640 working hours. Results: A significant moderate correlation between work ability and %HRR was observed among males (R = −0.33, P = 0.005), but not among females (R = 0.11, P = 0.431). In a gender-stratified multi-adjusted logistic regression analysis, males with high %HRR were more likely to report a reduced work ability compared to males with low %HRR [OR = 4.75, 95% confidence interval (95% CI) = 1.31 to 17.25]. However, this association was not found among females (OR = 0.26, 95% CI 0.03 to 2.16), and a significant interaction between work ability, %HRR and gender was observed (P = 0.03). Conclusions: The observed association between work ability and objectively measured %HRR over several days among male blue-collar workers supports the face validity of the single work ability item. It is a useful and valid measure of the relation between physical work demands and resources among male blue-collar workers. The contrasting association among females needs to be further investigated.
Keywords: work ability; face validity; relative aerobic workload; blue-collar workers; actiheart; objective measures
PDF Full-text Download PDF Full-Text [489 KB, Updated Version, uploaded 19 June 2014 04:01 CEST]
The original version is still available [489 KB, uploaded 19 June 2014 04:01 CEST]

Export to BibTeX |
EndNote


MDPI and ACS Style

Gupta, N.; Jensen, B.S.; Søgaard, K.; Carneiro, I.G.; Christiansen, C.S.; Hanisch, C.; Holtermann, A. Face Validity of the Single Work Ability Item: Comparison with Objectively Measured Heart Rate Reserve over Several Days. Int. J. Environ. Res. Public Health 2014, 11, 5333-5348.

AMA Style

Gupta N, Jensen BS, Søgaard K, Carneiro IG, Christiansen CS, Hanisch C, Holtermann A. Face Validity of the Single Work Ability Item: Comparison with Objectively Measured Heart Rate Reserve over Several Days. International Journal of Environmental Research and Public Health. 2014; 11(5):5333-5348.

Chicago/Turabian Style

Gupta, Nidhi; Jensen, Bjørn S.; Søgaard, Karen; Carneiro, Isabella G.; Christiansen, Caroline S.; Hanisch, Christiana; Holtermann, Andreas. 2014. "Face Validity of the Single Work Ability Item: Comparison with Objectively Measured Heart Rate Reserve over Several Days." Int. J. Environ. Res. Public Health 11, no. 5: 5333-5348.

Int. J. Environ. Res. Public Health EISSN 1660-4601 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert