Sensors 2004, 4(12), 187-195; doi:10.3390/s41200187
Article

Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode

Received: 15 April 2004; Accepted: 2 November 2004 / Published: 22 December 2004
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Abstract: A polystyrene-based membrane of 2,10-dimethyl-4,12-diphenyl-1,5,9,13-tetraazacyclohexadeca-1,4,9,12-tetraene macrocyclic ionophore was prepared and investigated as Cr(III)-selective electrode. The best performance was observed with the membrane having the polystyrene-ligand-dibutylphthalate-sodiumtetraphenyl borate composition 1:4:1:1 with a Nernstian slope of 19.0 mV per decade of concentration between pH 3.0 and 6.5. This electrode has been found to be chemically inert and of adequate stability with a response time of 20 s and was used over a period of 100 d with good reproducibility (S= 0.3 mV). The membrane works satisfactorily in a partially non-aqueous medium up to a maximum 30% (v/v) content of methanol and ethanol. The potentiometric selectivity coefficient values indicate that the membrane sensor is highly selective for Cr(III) ions over a number of monovalent, divalent and trivalent cations. The membrane electrode has also been successfully used to determine Cr3+ in various food materials.
Keywords: chromium-selective electrode; macrocyclic ionophore; potentiometric sensor
PDF Full-text Download PDF Full-Text [210 KB, uploaded 20 June 2014 23:33 CEST]

Export to BibTeX |
EndNote


MDPI and ACS Style

Singh, A.K.; Singh, R.; Saxena, P. Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode. Sensors 2004, 4, 187-195.

AMA Style

Singh AK, Singh R, Saxena P. Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode. Sensors. 2004; 4(12):187-195.

Chicago/Turabian Style

Singh, Ashok K.; Singh, Rupam; Saxena, Puja. 2004. "Tetraazacyclohexadeca Macrocyclic Ligand as a Neutral Carrier in a Cr Ion-selective Electrode." Sensors 4, no. 12: 187-195.

Sensors EISSN 1424-8220 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert