Next Article in Journal
V2X-Communication-Aided Autonomous Driving: System Design and Experimental Validation
Next Article in Special Issue
Wearable Sensors and Systems in the IoT
Previous Article in Journal
Smart Distribution Boards (Smart DB), Non-Intrusive Load Monitoring (NILM) for Load Device Appliance Signature Identification and Smart Sockets for Grid Demand Management
Previous Article in Special Issue
Medication Adherence and Liquid Level Tracking System for Healthcare Provider Feedback
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Correction

Correction: Zhang, P., et al. A Flexible Strain Sensor Based on the Porous Structure of a Carbon Black/Carbon Nanotube Conducting Network for Human Motion Detection. Sensors 2020, 20, 1154

Key Laboratory for Robot Intelligent Technology of Shandong Province, Shandong University of Science and Technology, Qingdao 266590, China
*
Author to whom correspondence should be addressed.
Sensors 2020, 20(10), 2901; https://doi.org/10.3390/s20102901
Submission received: 14 April 2020 / Accepted: 14 April 2020 / Published: 20 May 2020
(This article belongs to the Special Issue Wearable Sensors and Systems in the IOT)
The authors wish to make the following corrections to this paper [1]:
There are two non-academic errors should be corrected, we promise that the content of the paper will not be changed as a result of this corrections.
On page 6 of the paper [1], the original wording was as follows: “In order to verify the dynamic characteristics of the strain sensor, the sensor was stretched by 2%, 25%, 50% and 75% of its own length, and 10 stretch cycles were performed. The results shown in Figure 6b reveal that the R/R0 changes with the periodic changes in tension force and the sensor has a good regularity and stability”.
The corresponding Figure 6b in the original paper discusses the dynamic performance test of the sensor when it is stretched to 2%, 25%, 50% and 75% of its own length. Due to a clerical error in drawing, we wrote 10% instead of 2%, and the correct description is 2% instead of 10% which is shown in the following figure.
On page 7 of the paper [1], the original in the article read as follows: “The sensor was held under tensile strain for 70 s in order to verify the stability of the sensor under a prolonged state of tension. Furthermore, Figure 6c shows that the R/R0 tends to be stable after an overshoot peak (overshoot recovery time: 2 s, 5 s, 10 s, 14 s and 17 s), suggesting that the sensor recovers quickly and is able to perform reliably following the overshoot. This overshoot may be due to the acceleration caused by the tension meter as the sensor is stretched. At the same time, the influence of the tensile rate on the strain sensor was also investigated and the results are presented in Figure 6d. The test results show that at a tensile strain of 30%, as the tensile rate increases incrementally from 10 mm/min to 100 mm/min, the tensile rate has no obvious effect on the R/R0 of the strain sensor. This indicates that under external stresses at different frequencies, the sensor remains stable and can meet the needs of motion detection”.
In this paper, the phenomenon described in Figure 6c is actually the phenomenon expressed in Figure 6d in the original text, the phenomenon described in Figure 6d is actually the phenomenon expressed in Figure 6c in the original text. Therefore, the positions of Figure 6c,d need to be interchanged in the paper which is shown in the following figure.
The authors would like to apologize for any inconvenience caused to the readers by these changes in the paper.

Reference

  1. Zhang, P.; Chen, Y.; Li, Y.; Zhang, Y.; Zhang, J.; Huang, L. A Flexible Strain Sensors Based on the Porous Structure of Carbon Black/Carbon Nanotube Conduction Network for Human Motion Detection. Sensors 2020, 20, 1154. [Google Scholar] [CrossRef] [Green Version]
Figure 6. Schematic modification of the first error.
Figure 6. Schematic modification of the first error.
Sensors 20 02901 g001
Figure 6. Schematic modification of the second error.
Figure 6. Schematic modification of the second error.
Sensors 20 02901 g002

Share and Cite

MDPI and ACS Style

Zhang, P.; Chen, Y.; Li, Y.; Zhang, Y.; Zhang, J.; Huang, L. Correction: Zhang, P., et al. A Flexible Strain Sensor Based on the Porous Structure of a Carbon Black/Carbon Nanotube Conducting Network for Human Motion Detection. Sensors 2020, 20, 1154. Sensors 2020, 20, 2901. https://doi.org/10.3390/s20102901

AMA Style

Zhang P, Chen Y, Li Y, Zhang Y, Zhang J, Huang L. Correction: Zhang, P., et al. A Flexible Strain Sensor Based on the Porous Structure of a Carbon Black/Carbon Nanotube Conducting Network for Human Motion Detection. Sensors 2020, 20, 1154. Sensors. 2020; 20(10):2901. https://doi.org/10.3390/s20102901

Chicago/Turabian Style

Zhang, Peng, Yucheng Chen, Yuxia Li, Yao Zhang, Jian Zhang, and Liangsong Huang. 2020. "Correction: Zhang, P., et al. A Flexible Strain Sensor Based on the Porous Structure of a Carbon Black/Carbon Nanotube Conducting Network for Human Motion Detection. Sensors 2020, 20, 1154" Sensors 20, no. 10: 2901. https://doi.org/10.3390/s20102901

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop