Next Article in Journal
Correction: Lee, Y. et al. Geosensor Data Representation Using Layered Slope Grids. Sensors 2012, 12, 17074-17093
Previous Article in Journal
Computational Burden Resulting from Image Recognition of High Resolution Radar Sensors
Correction of Sensors 2011, 11(9), 8685-8710.

Sensors 2013, 13(4), 5403; doi:10.3390/s130405403
Correction

Correction: Zarzo, M. et al. Long-Term Monitoring of Fresco Paintings in the Cathedral of Valencia (Spain) through Humidity and Temperature Sensors in Various Locations for Preventive Conservation. Sensors 2011, 11, 8685-8710

1
,
2
 and
2,*
1 Department of Applied Statistics, Operations Research and Quality, Universidad Politécnica de Valencia, Camino de Vera s/n, 46022 Valencia, Spain 2 Department of Applied Physics (UD Agriculture Engineering), Universidad Politécnica de Valencia, Camino de Vera s/n, 46022 Valencia, Spain
* Author to whom correspondence should be addressed.
Received: 14 March 2013 / Revised: 25 March 2013 / Accepted: 25 March 2013 / Published: 22 April 2013
(This article belongs to the Section Chemical Sensors)
View Full-Text   |   Download PDF [114 KB, uploaded 21 June 2014]
SciFeed
Note: In lieu of an abstract, this is an excerpt from the first page.

Excerpt

A typo has been found in our paper [1]. It is stated on page 8698 that the range of acceptable temperature for the conservation of frescoes is 6–25 °C while in the case of RH, this range is 45%–60%, according to the Italian Standard UNI 10829 (1999). These recommended ranges of temperature (6–25 °C) and RH (45%–60%) correspond to the Standard DM 10/2001 [2], not to UNI 10829. The authors would like to apologize for any inconvenience this may have caused to the readers of this journal. [...]
This is an open access article distributed under the Creative Commons Attribution License (CC BY 3.0).

Share & Cite This Article

Further Mendeley | CiteULike
Export to BibTeX |
EndNote |
RIS
MDPI and ACS Style

Zarzo, M.; Fernández-Navajas, A.; García-Diego, F.-J. Correction: Zarzo, M. et al. Long-Term Monitoring of Fresco Paintings in the Cathedral of Valencia (Spain) through Humidity and Temperature Sensors in Various Locations for Preventive Conservation. Sensors 2011, 11, 8685-8710. Sensors 2013, 13, 5403.

View more citation formats

Related Articles

Article Metrics

For more information on the journal, click here

Comments

[Return to top]
Sensors EISSN 1424-8220 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert