Next Article in Journal
Pharmacokinetics and Excretion Studies on CDRI-85/92, an Antiulcer Proton Pump Inhibitor
Previous Article in Journal
Development and Validation of a Stability-Indicating RP-HPLC Method for the Simultaneous Determination of Phenoxyethanol, Methylparaben, Propylparaben, Mometasone Furoate, and Tazarotene in Topical Pharmaceutical Dosage Formulation
Article Menu

Article Versions

Export Article

Open AccessArticle
Sci. Pharm. 2013, 81(4), 969-982; doi:10.3797/scipharm.1305-14

Stability-Indicating RP-HPLC Method for the Simultaneous Estimation of Doxofylline and Terbutalinesulphate in Pharmaceutical Formulations

1
Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research (NIPER), Balanagar, Hyderabad, India
2
United States Pharmacopeia – India Private Limited, Research and Development Laboratory, ICICI Knowledge Park, Turkapally, Shameerpet, Hyderabad, India
*
Author to whom correspondence should be addressed.
Received: 7 May 2013 / Accepted: 14 July 2013 / Published: 14 July 2013
Download PDF [410 KB, uploaded 29 September 2016]

Abstract

An isocratic, stability-indicating, reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for the quantitative determination of doxofylline and terbutaline sulphate, used for the treatment of respiratory problems. The chromatographic separation was achieved on a Zorbax-SB Phenyl 250 x 4.6mm x 5 μm column with the mobile phase consisting of a mixture of 25 mM ammonium acetate (pH 5.0) : acetonitrile (85:15 %v/v) at a flow rate of 1.0 ml/min. The eluate was monitored at 274 nm using a PDA detector. Forced degradation studies were performed on the bulk sample of doxofylline and terbutaline sulphate using acid (0.1N HCl), base (0.1N NaOH), oxidation (10% hydrogen peroxide), photolytic, and thermal degradation conditions. Good resolution was observed between the degradants and analytes. Degradation products resulting from the stress studies did not interfere with the detection of doxofylline and terbutaline sulphate, thus the assay is stability-indicating. The method has the requisite accuracy, selectivity, sensitivity, and precision for the simultaneous estimation of doxofylline and terbutaline sulphate in bulk and pharmaceutical dosage forms. The limit of quantitation and limit of detection were found to be 1.16 μg/ml and 0.38 μg/ml for doxofylline, 2.08 μg/ml and 0.62 μg/ml for terbutaline sulphate, respectively.
Keywords: Doxofylline; Method Development; Chromatography; Stability; Terbutaline sulfate; Validation Doxofylline; Method Development; Chromatography; Stability; Terbutaline sulfate; Validation
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. (CC BY 4.0).

Scifeed alert for new publications

Never miss any articles matching your research from any publisher
  • Get alerts for new papers matching your research
  • Find out the new papers from selected authors
  • Updated daily for 49'000+ journals and 6000+ publishers
  • Define your Scifeed now

SciFeed Share & Cite This Article

MDPI and ACS Style

SAMANTHULA, G.; YADIKI, K.; SALADI, S.; GUTALA, S.; SURENDRANATH, K.V. Stability-Indicating RP-HPLC Method for the Simultaneous Estimation of Doxofylline and Terbutalinesulphate in Pharmaceutical Formulations. Sci. Pharm. 2013, 81, 969-982.