Energies 2014, 7(4), 2146-2147; doi:10.3390/en7042146

Correction
Correction: Márquez-Domínguez, S.; Sørensen, J.D. Fatigue Reliability and Calibration of Fatigue Design Factors for Offshore Wind Turbines. Energies 2012, 5, 1816–1834
Sergio Márquez-Domínguez * and John D. Sørensen
Aalborg University, Sohngaardsholmsvej 57, DK-9000 Aalborg,Denmark; E-Mail: jds@civil.aau.dk
*
Author to whom correspondence should be addressed; E-Mail: smd@civil.aau.dk; Tel.: +45-9940-8575; Fax: +45-9940-8552.
Received: 29 January 2014 / Accepted: 26 February 2014 / Published: 1 April 2014

The authors wish to make the following correction to this paper [1]. On page 1831, the titles of Tables 18 and 19 were incorrect, and should be changed from to the correct versions as follows:

The authors would like to apologize for any inconvenience caused to the readers by this change.

Reference

  1. Márquez-Domínguez, S.; Sørensen, J.D. Fatigue Reliability and Calibration of Fatigue Design Factors for Offshore Wind Turbines. Energies 2012, 5, 1816–1834.
Table Table 18. Required FDF values for minimum cumulative reliability level. SN-curve: “With cathodic protection”. Inspections with the eddy current technique.

Click here to display table

Table 18. Required FDF values for minimum cumulative reliability level. SN-curve: “With cathodic protection”. Inspections with the eddy current technique.
β/number of inspections012410
2.53.42.72.31.31
3.16.15.04.12.81
Table Table 19. Required FDF values for minimum cumulative reliability level. SN-curve: “With cathodic protection”. Close visual inspection.

Click here to display table

Table 19. Required FDF values for minimum cumulative reliability level. SN-curve: “With cathodic protection”. Close visual inspection.
β/number of inspections012410
2.53.42.72.31.31
3.16.15.04.12.81
Table Table 18. Required FDF values for minimum cumulative reliability level. SN-curve: “With cathodic protection”. Close visual inspection.

Click here to display table

Table 18. Required FDF values for minimum cumulative reliability level. SN-curve: “With cathodic protection”. Close visual inspection.
β/number of inspections012410
2.53.43.02.72.31
3.16.15.35.03.61.3
Table Table 19. Required FDF values for minimum cumulative reliability level. SN-curve: “With cathodic protection”. Inspections with the Eddy Current technique.

Click here to display table

Table 19. Required FDF values for minimum cumulative reliability level. SN-curve: “With cathodic protection”. Inspections with the Eddy Current technique.
β/number of inspections012410
2.53.43.02.72.31
3.16.15.35.03.61.3
Energies EISSN 1996-1073 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert