Next Article in Journal
A Transformer Partial Discharge Measurement System Based on Fluorescent Fiber
Next Article in Special Issue
An Overview of Two Years of Continuous Energy Optimization at the Velenje Coal Mine
Previous Article in Journal
Online Estimation of Peak Power Capability of Li-Ion Batteries in Electric Vehicles by a Hardware-in-Loop Approach
Previous Article in Special Issue
Exergy Assessment of Recovery Solutions from Dry and Moist Gas Available at Medium Temperature
Energies 2012, 5(5), 1470-1489; doi:10.3390/en5051470
Article

Efficiency of Small Scale Manually Fed Boilers —Mathematical Models

1,* , 2
, 1
, 1
, 1
, 1
 and 1
Received: 27 February 2012; in revised form: 17 April 2012 / Accepted: 3 May 2012 / Published: 15 May 2012
Download PDF [358 KB, uploaded 15 May 2012]
Abstract: This study reviews test results for a biomass-fired hot water boiler with a nominal boiler thermal power of 120 kW. In the experiments, prismatic wheat straw bales were used as biomass. The impact of the quantity (220, 290, 360 and 430 m3 h−1) of inlet air fed to the boiler firebox was continuously monitored. This was to examine the influence of the quantity of inlet air and recirculation (0, 16.5 and 33%) of combustion products on the boiler thermal power and boiler energy efficiency. Thus, the following mathematical models and formulas were presented: correlation between boiler thermal power and bale residence time; bale mass loss during the combustion process; correlation between boiler energy efficiency and bale residence time. Mathematical models were obtained by using experimental data and by applying nonlinear regression analysis. Adjustment evaluation of mathematical models with experimental data was performed based on the determination coefficient, t-test and F-test. Increase the amount of air throughout the firebox produced boiler thermal power increase and bale residence time decrease. It was shown that combustion products recirculation of 16.5% partly improved boiler characteristics, while the recirculation of 33% did not, comparing with the case without recirculation.
Keywords: energy efficiency; mathematical models; non-linear regression; recirculation; wheat straw combustion energy efficiency; mathematical models; non-linear regression; recirculation; wheat straw combustion
This is an open access article distributed under the Creative Commons Attribution License which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Export to BibTeX |
EndNote


MDPI and ACS Style

Dedovic, N.; Igic, S.; Janic, T.; Matic-Kekic, S.; Ponjican, O.; Tomic, M.; Savin, L. Efficiency of Small Scale Manually Fed Boilers —Mathematical Models. Energies 2012, 5, 1470-1489.

AMA Style

Dedovic N, Igic S, Janic T, Matic-Kekic S, Ponjican O, Tomic M, Savin L. Efficiency of Small Scale Manually Fed Boilers —Mathematical Models. Energies. 2012; 5(5):1470-1489.

Chicago/Turabian Style

Dedovic, Nebojsa; Igic, Sasa; Janic, Todor; Matic-Kekic, Snezana; Ponjican, Ondrej; Tomic, Milan; Savin, Lazar. 2012. "Efficiency of Small Scale Manually Fed Boilers —Mathematical Models." Energies 5, no. 5: 1470-1489.


Energies EISSN 1996-1073 Published by MDPI AG, Basel, Switzerland RSS E-Mail Table of Contents Alert